1 / 13

B: 同軸電纜 C=(24.13xε)÷log[(D+1.5d)/(Kxd1)]

leanna
Download Presentation

B: 同軸電纜 C=(24.13xε)÷log[(D+1.5d)/(Kxd1)]

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 一:導體1.絞合外徑 束絞: D=√N x 1.155 x d 2.重量(Kg/km)= d2 x 0.7854 x 8.89 x N x C x 1.02e(d=線徑 N=導体條數 C=芯數 1.02=絞入率 e=導体之相關工程絞合次數)3. 絞入率=(外沿線長-中心線長)÷中心線長「本廠適用參考值為1.02」二:絕緣1.外徑=絕緣厚度 X 2+上過程外徑2. 重量(kg/km)=(D2-d2xλ)x0.7854xGxCx1.02e【注:單支導体λ=1;絞合導体λ=0.85】(D=絕緣外徑 d=導体外徑 G=比重 C=芯數 1.02=絞入率 e=絕緣工程之絞合次數)三:外被用量計算:總原則 : 截面積 x 單位長度(1KM)x 比重1.充實型押出:重量(kg/km)= (D2-d2Xc) x 0.7854 x G(D=完成外徑 d=芯線外徑 G=比重 C=芯數) 2.半管型押出:重量(kg/km)=(D2-d2 xλ)x0.7854xG(D=完成外徑 d=押出前集合芯線外徑 G=比重 λ=編織纏繞取0.95,包紙包帶取0.90)

  2. 3. 套管型押出:重量(kg/km)=(D2-d2)x0.7854xG(D=完成外徑 d=押出前集合芯線外徑 G=比重)4.SPT型線材絕緣用量計算4.1 兩芯線重量(kg/km) =[T2x0.7854+Tx(W-T)-d1x d1x0.7854x0.85x2-ax(T-h)/2+0.3x0.4x2] x G4.2 兩芯線重量(kg/km) =[T2x0.7854+Tx(W-T)-d1x d1x0.7854x0.85x2-d2x0.7854-ax(T-h)+毛邊寬度x毛邊高度x2] x G 重量(Kg/Km)=[ T2 x 0.7854+T x(W-T)- d2 x 0.7854 x N ] x G (W=寬度 T=厚度 d=芯線徑 N=芯數 G=比重)四:集合 1. 多芯線(電腦線&電源線)集合絞距本廠設定為層心徑的30倍左右[*參考數據]2. 集合外徑 D=Kxd [K為系數,請查閱多芯絞合系數表;d為芯線外徑]

  3. 五:包帶1.寬度=包帶前線徑的 3~5 倍2.厚度=[ AL-MYLAR: 0.025 mm 棉紙:0.03 mm 絕緣紙:0.04 mm ]3.重量=厚度x(包帶前線徑+厚度)xPI()x重疊率x比重 (注:重疊率1/4Lap=1.25)4.方向:本廠棉紙、絕緣紙一般為斜包,1/4Lap;AL-MYLAR單隔離時為斜向反包AL-MYLAR雙隔離時為斜向正包)六:填充條1.種類(本廠填充材料有沖麻PPR和棉繩,前者一般用於電源線,有時也用於少數 芯線較大的電腦線:後者一般用於電腦線填充料。)2.重量=填充物截面積 x 比重七:纏繞:1.重量(kg/km)= d2 x 0.7854 x G x N / COS ( ATAN ( n x D + PI() x (D + d))/ h )2.遮蔽率=(Nxd)/ COS ( ATAN ( n x D + PI() x (D + d))/ h )/(n x D + PI() x ( D + d))3.最少條數(N)=[93%x COS(ATAN(n xD +PI()x(D+d))/h)/(n xD+PI()x(D+d))]÷d(注:本廠纏繞線遮蔽率一般要求達93%以上,纏繞所需條數視情節可±2條。)4.纏繞絞距[參考絞距=nxD+PI()x(D+d)] ÷TANα α一般取 13~15。]本廠之常用絞距有:(36 32 27 25 22 18 15 13.5 11.5 9.5 8.5) 參數說明:d單根銅線線徑;n芯線數;D芯線線徑;N纏繞條數; G比重 h絞距

  4. 八:編織1.重量(Kg/Km)=(d2xO.7854xGxTxN)÷COSθ【θ=ATAN(2xPI()x(D+2d)xP÷T÷25.4)】 2.遮蔽率 S=1-(1-F)2 F=( N x d x P) Sinθ注: s:雙方向遮蔽率; F:單方向遮蔽率; T:錠數; N:每錠條數; d:編織銅線線徑; D:編織前線徑; θ:編織角度3.編織外徑:=D+4d 4.編織機一般操作范圍: (1)編織角度 θ: 一般取30~45。。(2)每錠條數 N : 一般為5~12條。(3)每吋目數 P : 一般為8~12目。九:材質比重1.導体 銅(裸、鍍錫)=8.89g/cm3 銅包鋼=8 g/cm3 鋁=2.70 g/cm32.絕緣&外被 一般PVC=1.45 透明PVC=1.22 SR-PVC=1.47 LDPE=0.94 HDPE=0.97 FRPE=1.70 發泡PE=0.65 PP=0.97 TPE=0.97 PU=1.21 TEFLON=2.123.帶類 棉紙=0.60 MYLAR=1.37 AL-MYLAR=1.80 絕緣紙=1.35棉布帶=0.55(假比重)4.沖麻重量(Kg/Km)*參考值8000D=0.98 10000D=1.20 12000D=1.50 14000D=1.75 16000D=2.00 18000D=2.25

  5. 十:抗張強度及伸長率【此項供試驗時計算用】 1.抗張強度(P)=F÷S[單位:kgf/mm2]注:F=斷裂拉斷力(Kg) S=橫截面積 伸長率(E)=(L-LO)x100% LO=標線距離 L:拉斷時標線間長度十一:電氣特性1.導体電阻 R(Ω/Km) 直流電阻 R(Ω/Km)=17.24÷(A x C x K) =17.24÷(d2x0.7854xNxCxK) 概略計算R=24.4÷d2÷N注:A=截面積 C=導電率 K=導體絞合系數 d=導體線徑 N=導體倏數2.絕緣電阻IR(MΩ/Km)=1.592x10-12xρx log(D/d) ρ:体積固有電阻(概估值) 注: PVC=5x1013 (1013~1015) PE=2.5x1015 (>1015) FPE=5x1013 (>1015) Nylon=2x1011 PU =2x1014 PVC=2.5x1015(>1015)3.靜電容量 C (Pf/M)A:對型電纜 C=(12.06xε)÷log(1.2xD/Kd1)或A:對型電纜(F/M) C=(12.08xε)÷log10[2a+√(2a)*(2a)-(k*d1)]/d1)隔離多對時(Nf/KM) C=(27.8xε)÷ln(0.94D/d1) 2a d1

  6. d1 D B:同軸電纜 C=(24.13xε)÷log[(D+1.5d)/(Kxd1)] 其中: ε=介電常數; D=絕緣外徑; d=編織銅線徑; d1=內部導體外徑;K=系數導體條數N=1,K=1 N=7,K=0.94 N=12,K=0.96 N=19,K=0.974.特性阻抗A:同軸電纜(Z)=(138.1/√ε)xlog[(D+1.5d)/(Kxd1)]B:對型電纜(Z)=(276/√ε)xlog[(1.2xD)/Kd1]注: ε取值 PVC=(5~7) PE=2.3 PEF20%=2.0 PEF30%=1.85 PEF40%=1.71 PEF50%=1.58 PEF60%=1.46 PEF70%=1.33 Nylon=3.5 PP=2.6 FEP=2.204.發泡度之計算步驟(1)先根據線材要求之特性阻抗逆推計算出發泡度之ε。(2)再根據以下公式計算出發泡度。公式: F=(3.6εe-2εe2+2.3)÷3.9ε外模選擇: D=SQRT[(1-F)(d12-d2)+d2] d1=絕緣外徑; d=導體外徑xK(同上列系數值)

  7. 附錄(一)**集合外徑計算之絞合系數表情(D=Kxd)

  8. **對絞集合外徑計算之絞合系數表 情(D=Kxd)

  9. 附錄(二)**各種形狀面積及體積計算公式:

  10. 附錄(三)**各規格導體最大直流電阻標準值:

  11. 附錄(四)**SPT型電源線連體及毛邊尺寸表:

  12. **單根銅線線徑公差表: **單根銅線線徑公差表: