1 / 8

Durability of Post-Tensioned Structures Grout Specifications Durability Design Details

Durability of Post-Tensioned Structures Grout Specifications Durability Design Details. Durability and Post-Tensioning. moisture, Cl - , CO 2. Extremely durable when properly constructed Crack control Multiple protection levels. concrete. duct. grout.

lei
Download Presentation

Durability of Post-Tensioned Structures Grout Specifications Durability Design Details

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Durability of Post-Tensioned StructuresGrout SpecificationsDurability Design Details

  2. Durability and Post-Tensioning moisture, Cl-, CO2 • Extremely durable when properly constructed • Crack control • Multiple protection levels concrete duct grout The grout is the last level of protection for the strand strand

  3. Purpose of Grout • Corrosion protection • Bond

  4. Properties • Fluidity • Bleed • Segregation • Set Time • Strength • Permeability • Volume Change • Corrosion Protection Bleed

  5. Bleed in Grouts Bleed • Bleed water is trapped in duct • Higher vertical rises = higher pressures and more bleed water • Strand promotes bleed by wicking Intermediate lense

  6. Bleed Lenses • Voids • Loss of protective environment 9 ¾” bleed column Intermediate lense

  7. Keys to a Good Grout • Completely fills duct • Low permeability • Appropriate bleed resistance • Careful use of admixtures Many admixtures help one grout property while degrading another

  8. Tasks under WO-81 • Literature review and summary of current practice • Development of specification language, details, and revisions to PennDOT publications • Scope includes • Grouting (materials, procedures, venting) • Durability details (anchorage, duct material) • Inspection/repair • Training of personnel