1 / 22

Chandra Calibration Status

Highlights of the IACHEC Meeting Updates to the LETG/HRC-S calibration Continuous Clocking (CC) mode calibration. Chandra Calibration Status. 2010 IACHEC Meeting in Woods Hole (April 12-15). Attended by 45 scientists

Download Presentation

Chandra Calibration Status

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Highlights of the IACHEC Meeting • Updates to the LETG/HRC-S calibration • Continuous Clocking (CC) mode calibration Chandra Calibration Status

  2. 2010 IACHEC Meeting in Woods Hole (April 12-15) • Attended by 45 scientists • Representatives from Chandra, XMM-Newton, Suzaku, IXO, Swift, Integral, RXTE, MAXI, Hinode, NuStar and GEMS. • 9 paper are being prepared for A&A with IACHEC in the title. • IACHEC Report: Cross-calibration with Clusters of Galaxies • IACHEC Report: Cross-calibration with Blazars • IACHEC Report: Cross-calibration with E0102-72 • IACHEC Report: Cross-calibration with G21.5-09 • IACHEC Report: Cross-calibration with White Dwarfs and Isolated Neutron Stars

  3. XMM-Newton/Chandra Blazar Flux Comparison – Smith & Marshall

  4. Cross-Calibration with Clusters of GalaxiesAbell 2029 (z=0.0773, kT=8.0 keV)

  5. 2010 IACHEC – Nevalainen & David 2-7 keV energy band

  6. 2010 IACHEC - Plucinsky E0102-72

  7. Recent Updates to the LETG/HRC-S Effective Area - CALDB 4.2.1

  8. Relative adjustments to the LETG higher order efficiencies

  9. Operating Modes 1. Timed event mode (TE) 2. Continuous Clocking Mode (CC) Telemetry Formats 1. Very faint (VF) 5 x 5 2. Faint (F) 3x3 3. Graded ACIS

  10. ACIS CC Faint Mode Calibration ACIS Flight Grades

  11. CC Faint Mode Calibration Comparison of TE and CC Flight Grade Distribution New SI Mode for CC observations telemeters all flight grades except 24, 107, 127, 214, 223, 248, 251 and 255

  12. Order sorting plot for HETG/ACIS-S spectrum 3 column averaged trap map Single column trap maps are now being generated for CC-F mode data based on the AL-Ka line in the ECS data

  13. HETG/ACIS-S observations of bright sources in CC-G Mode

  14. Features near the Si-K edge in HETG/ACIS-S observations of bright sources in CC-G mode

  15. New CC Mode Calibration Products • Single column trap maps for all BI chips to apply cti corrections to CC-F mode data. • QE tables for old CC SI_Mode and new CC SI_Mode (additional flight grades) • Method for applying cti-corrections to CC-G mode data.

More Related