1 / 2

Applicomp, Bangalore

Temporary C/M for Water dripping in 310 DC. Apply instant bonding glue( Quick fix,Anabond etc) across the strip. Paste the strip on rib( located below the evaporator) and press it.

Download Presentation

Applicomp, Bangalore

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Temporary C/M for Water dripping in 310 DC Apply instant bonding glue( Quick fix,Anabond etc) across the strip Paste the strip on rib( located below the evaporator) and press it After pasting the Strip water falling from evaporator falls chiller tray and no splashing on ref compartment Applicomp, Bangalore

  2. Permanent C/M for Water dripping in 310 DC Topic : Water Dripping in Ref compartment – 310 DC Description : Modification of rib below Evaporator to ensure water drips in Chiller tray during defrost Previous condition Improved condition Date : 07/06/14 Person Name: Gururaj Department: Production Area: Vacuum Forming Water falling from rib in chiller tray edge and splashing Water falling inside chiller tray & no splashing out side Chiller tray Chiller tray Quality Productivity 5S & 3R Rib Width – 39 mm 39mm 52 mm Rib Width increased to 52 mm Cost Safety Others Backlogs: Enrichments: √ Rib width increased to 52 mm During defrost water drops falling inside chiller tray There is no splashing of water drops in ref compartment Water drops from rib falling near edge of the chiller tray. In some sets water drops splashing out side chiller tray and falling in ref compartment Applicomp, Bangalore Continual Improvement Process

More Related