Temporary C/M for Water dripping in 310 DC. Apply instant bonding glue( Quick fix,Anabond etc) across the strip. Paste the strip on rib( located below the evaporator) and press it.
E N D
Temporary C/M for Water dripping in 310 DC Apply instant bonding glue( Quick fix,Anabond etc) across the strip Paste the strip on rib( located below the evaporator) and press it After pasting the Strip water falling from evaporator falls chiller tray and no splashing on ref compartment Applicomp, Bangalore
Permanent C/M for Water dripping in 310 DC Topic : Water Dripping in Ref compartment – 310 DC Description : Modification of rib below Evaporator to ensure water drips in Chiller tray during defrost Previous condition Improved condition Date : 07/06/14 Person Name: Gururaj Department: Production Area: Vacuum Forming Water falling from rib in chiller tray edge and splashing Water falling inside chiller tray & no splashing out side Chiller tray Chiller tray Quality Productivity 5S & 3R Rib Width – 39 mm 39mm 52 mm Rib Width increased to 52 mm Cost Safety Others Backlogs: Enrichments: √ Rib width increased to 52 mm During defrost water drops falling inside chiller tray There is no splashing of water drops in ref compartment Water drops from rib falling near edge of the chiller tray. In some sets water drops splashing out side chiller tray and falling in ref compartment Applicomp, Bangalore Continual Improvement Process