1 / 3

Infant-Incubator-AM-II31

Abimed Infant Incubator offers computer-controlled convective heat, over-temperature protection, an adjustable bed, and an LED display. It supports a temperature range of 25u00b0C to 37u00b0C up to 38u00b0C with a 45-minute warm-up for optimal infant care.

lindahaley
Download Presentation

Infant-Incubator-AM-II31

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. www.abimed.com | info@abimed.com

  2. Infant Incubator AM-II31 Infant Incubator AM-II31 uses convective heat regulation to servo control the temperature of incubator using computer technology. Equipped with a baby cabin, temperature controller, an incubator chassis and a blue light irradiation light box. Triple protection for over temperature with separate cut off device and more safety system. Inclination of infant bed is adjustable. A keypad lock helps to prevent inadvertent changes in the setting. LED display indicates set temperature, air temperature and heating power. Equipped with single wall hood, four operating windows and 2 iris portis. Features Temperature deviation and over temperature could be amended in front panel directly Integral timer to record therapy time Locking device for front door RS232 interphase is used as connector Alarm functions for over temperature, power failure, temperature deviation and fan failure Humidity is adjustable in two beds Provided with oxygen inlet and cabinet base Technical Parameter Model AM-II31 Power Supply ~220V, 50/60Hz Power Input 650VA (including power output socket :200VA) Ambient 200C to 300C Operation environment conditions Temperature Ambient Humidity 30% RH to 75% RH Ambient air pressure 700 hPa to 1060 hPa Ambient air velocity <0.3m/s Control temperature range 250C to 370C, 37.10C to 380C Warm-up time 45 minutes CO2-concentration 0.4% Noise noise in the baby cabin less than 55dB(A)

  3. Infant Incubator AM-II31 Relative humidity ≤95%RH Atmospheric Pressure Range 500hPa to 1060hpa Applications These are widely used in hospitals, it is designed to ensure a safe controlled space for infants to live while their vital organs develop

More Related