1 / 13

EDM

Calypso. Prerequisite. General Information. Adjustments. EDM. File Conf.dat. Example. Interfaces. Supported EDM Systems. The user needs: The offset and the rotation of an electrode (A) to a chuck (B). What the user makes available: a high-exact chuck on the CMM (B)

Download Presentation

EDM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Calypso • Prerequisite • General • Information • Adjustments EDM • File Conf.dat • Example • Interfaces • Supported • EDM Systems

  2. The user needs: • The offset and the rotation of an • electrode (A) to a chuck (B). • What the user makes available: • a high-exact chuck on the • CMM (B) • a same chuck in the EDM • machine • an electrode (A) with attachment • (C) for the chuck C Y X B A C

  3. C Y X • General • Every CMM user can generate • offset Data for EDM operation • Case A • The CMM generates offset information • (X,Y, Z and Rotation angle C), • Results are entered manually into • EDM System • - Pro: no interface necessary • - Con: time consuming and prone to operator typing error

  4. Case B Step1 CMM generated offsets are transmitted automatically via interface to EDM controller. The Special Option EDM in UMESS UX, Calypso or ScanWarePRO main function is: Save values of 2 different Coordinate Systems to an ASCII-file with a given file name ERODIER. EDM

  5. Case B • Step 2 ( This step occurs automatically each time of arrival of • new file to Controller of EDM System) • The Program EPOST.EXE calculates from both coordinate systems the Offset X,Y.Z and Rotation Angle C and additional into an ASCII-file of selected EDM system   • - This EDM–file recognizes Controller of EDM System • The only necessary input by Operator is the Type of EDM • System and File-name. (EPOST.EXE acts automatically)

  6. with Calypso Calypso ( available > version 4.6) Establishing of 2 Coordinate System 1. Option EDM Operator selects: -  --Coordinate System Chuck of Electrode Holder -   - Coordinate System Electrode -   - Directory and name of output file -    - Name of Electrode -   - Type of EDM System -   - Program Module to generate EDM information 2. 3. Calypso Sends ASCII-File Erodier.edm 4. • Epost.exe • calculates contents • of output file • stores output file Steps 4. and 5. are done automatically 5.

  7. with Calypso Example for input in Calypso Preparing-    Assistance   EDM –Module Or by using Toolbox, Insert EDM-Module in Inspection plan Calypso

  8. X Example for one of the different interfaces definitions Y0 C Y X0

  9. Supported EDM Manufacturers • MaschName1=Charmilles • MaschName2=Zimmer & Kreim • MaschName3=Mitsubishi • MaschName4=SGL • MaschName5=Hansen • MaschName6=AEG Elotherm S • MaschName7=Makino • MaschName8=Agie • MaschName9=Maho-Hansen • MaschName10=Ingersoll • MaschName11=Walter Exeron • MaschName12=AEG Elotherm • MaschName13=Charmilles N • MaschName14=Jung • MaschName15=AGIE Evolution • MaschName16=EMT • MaschName17=Multiform • MaschName18=System 3R • MaschName19=FANUC

  10. Example Interface Agie or Zimmer & Kreim In file Conf.dat the switch settings of 8 ( 0 or 1) determines the output information  ( Sign, applying or not applying C…….see example below) File Conf.dat (AGIE-Format- stored in C:)\TEMP\AGIE\)

  11. X‘ X‘0 Y‘0 = -C‘ Y‘ Conf.datInfluence to the results 2 File Conf.dat In file Conf.dat the switch settings of 8 ( 0 or 1) determines the output information  ( Sign, applying or not applying C…….see example below) Attention! A 1 at the 5. position works like trading of the coordinate-systems Both results were generated with the same File erodier.edm

  12. Conf.dat Influence to the results 2 Examle Agiewith EPOST.EXE Rel. Date March 5, 2002 1. 2. 3. 4. 5. 6. 7. 8. 0 0 0 0 0 0 0 0 | | | | | | | |_ 8. code Electrode / workpiece* | | | | | | |_ 7. free | | | | | |_ 6. free | | | | |_ 5. basic (1 exchanges basic system !) | | | | | | | |_ 4. +/-C (1 exchanges +/- C) | | |_ 3. +/-Z (1 exchanges +/- Z) | |_ 2. +/-Y (1 exchanges +/- Y) |_ 1. +/- X (1 exchanges+/- X) always stored in C:\TEMP\Agie \ Each measurement gets a directory? Title: ELE-1.....i or WKS-1....i File Name: MESSDAT.ASC 0 ELEKEle,M,-38.611,34.783,50.242,-7.740; 1 WKSEle,M,-38.611,34.783,50.242,-7.740; 0 ELEKEle,M,-38.611,34.783,50.242,-7.740; 1 ELEKEle,M,-42.944,29.266,50.242,7.740;

  13. Conf.dat Influence to the results 3 Example Agie Evolutionwith EPOST.EXE Rel. Date March 5, 2002 1. 2. 3. 4. 5. 6. 7. 8. 0 0 0 0 0 0 0 0 | | | | | | | |_ 8. code Electrode / workpiece* | | | | | | |_ 7. free | | | | | |_ 6. free | | | | |_ 5. basic (1 exchanges basic system !) | | | | | | | |_ 4. +/-C (1 exchanges +/- C) | | |_ 3. +/-Z (1 exchanges +/- Z) | |_ 2. +/-Y (1 exchanges +/- Y) |_ 1. +/- X (1 exchanges+/- X) Stored at ....\Agie.mes Each measurement generates another line at the end of the files Agie.mes 0 ELEKEle,M,-38.611,34.783,50.242,-7.740; 1 WKSEle,M,-38.611,34.783,50.242,-7.740; 0 ELEKEle,M,-38.611,34.783,50.242,-7.740; 1 ELEKEle,M,-42.944,29.266,50.242,7.740;