1 / 24

Small-Amplitude Vibration Tests of a Full-Scale RC Flat-Plate Structure

Small-Amplitude Vibration Tests of a Full-Scale RC Flat-Plate Structure. By: Luis Arboleda. MSCE Thesis. Problem Definition. Hypothesis. “The natural frequencies and lateral stiffness of a 3D RC flat-plate structure can be estimated using a conventional 2D frame analysis”. Specimen. α.

livi
Download Presentation

Small-Amplitude Vibration Tests of a Full-Scale RC Flat-Plate Structure

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Small-Amplitude Vibration Tests of a Full-Scale RC Flat-Plate Structure By: Luis Arboleda MSCE Thesis

  2. Problem Definition

  3. Hypothesis “The natural frequencies and lateral stiffness of a 3D RC flat-plate structure can be estimated using a conventional 2D frame analysis”

  4. Specimen

  5. α Exterior Interior 0.35-0.60 0.55-0.85 Pecknold (1975) Allen and Darvall (1977) 0.65 0.45 0.50 0.65 Banchik (1987) Hwang and Moehle (1993) 0.15-0.40 0.20-0.65 Literature Review

  6. Elevation View Plan View Test Setup 15

  7. Typical Result

  8. Test Results

  9. 1.32 1.27 2.09 1.98 1.69 1.58 86 79 1.20 1.16 2.09 1.98 1.34 1.30 86 79 f and k for Ec= 3800 ksi

  10. Length 0.5% Check as-built dimensions Width 0.5% Depth 0.9% ? Ec Variables to Calculate k 7

  11. 1.19 1.14 2.09 1.98 1.36 1.27 86 79 1.08 1.05 2.09 1.98 1.09 1.05 86 79 f and k for Ec= 4700 ksi 1.32 1.20

  12. 1.08 1.04 2.09 1.98 1.12 1.05 86 79 0.98 0.95 2.09 1.98 0.90 0.87 86 79 f and k for Ec= 5700 ksi 1.19 1.08

  13. α 2D Frame Analysis Exterior Frames Interior Frames 2.09 1.98 86 79 α for Ec= 4700 ksi 0.5

  14. α 2D Frame Analysis Exterior Frames Interior Frames 2.09 1.98 86 79 α for Ec= 5700 ksi 0.3

  15. Is it plausible that Ec is larger than 3800 ksi?

  16. Pauw (1960)

  17. CYLINDER C-3 EC,ASTM= 3950 ksi Ec of the Flat-Plate Structure Ecmean= 4000 ksi 6

  18. Could Ec be Larger than EC,ASTM?

  19. More Cylinders 32

  20. Small Stresses

  21. Free-Vibration Tests 15 Tests, 6L, 9M

  22. Free-Vibration Test Results

  23. Stresses in the Pull-Release Test

  24. Conclusions • The secant modulus of concrete can be larger than 1.25× EC,ACI (or 1.2 × EC,ASTM) for σ< fC’/15. • α= 1/2 can be used to model a 3D flat-plate structure using 2D frame analyses. • (It was obtained assuming EC= 1.25 × EC,ACI).

More Related