1 / 24

Presenter Disclosure Information

Multi-center Assessment of the Utilization of SPECT Myocardial Perfusion Imaging Using the ACCF Appropriateness Criteria: The ACCF and United Healthcare SPECT Pilot Study.

lois
Download Presentation

Presenter Disclosure Information

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Multi-center Assessment of the Utilization of SPECT Myocardial Perfusion Imaging Using the ACCF Appropriateness Criteria: The ACCF and United Healthcare SPECT Pilot Study Robert C. Hendel, Manual Cerqueira, Kathleen Hewitt, Karen Caruth, Joseph Allen, Neil Jensen, Michael Wolk, Pamela S. Douglas, Ralph Brindis, American College of Cardiology Foundation, Washington, DC, UnitedHealthcare, Minneapolis, MN Robert C. Hendel, MD, FACC Midwest Heart Specialists Winfield, IL Chairman, ACCF/UHC SPECT-MPI Pilot Study Late Breaking Clinical Trials American College of Cardiology Scientific Sessions 2009 March 29, 2009

  2. Presenter Disclosure Information Robert C. Hendel, MD The following relationships exist related to this presentation: Consulting PGx Health Modest Astellas Pharma Modest GE Healthcare Modest Research support Astellas Modest GE Healthcare Modest Organizational ACC (Appropriate Use Criteria Task Force)

  3. BACKGROUND • Growth and cost of CV imaging has placed renewed attention on proper/optimal test ordering • True nature of utilization unknown • Overuse/underuse/appropriate use • Development and publication of SPECT-MPI appropriate use criteria (AUC) in 2005 • Subsequent AUC for echo, CT, CMR • SPECT MPI revision 2009 • Criteria widely available and increasingly being adopted, but evaluation in community practice settings required

  4. GOALS OF STUDY • Assess feasibility of tracking AUC • Point-of-service data collection • Computer derived indication assignment • Determine patterns of use for SPECT MPI in clinical practice • Evaluate the impact of referral source • Identify selected areas (indications) for quality improvement

  5. METHODS • Sites selected by ACC from potential locations provided by UHC • Data collection instrument and web-based entry system developed • Automated algorithm created • On-demand reports • Periodic overall and site-specific summaries provided • Audit of automated indication assignments

  6. DATA COLLECTION FORM • Front page • Patient Demographics • History & Risk Factors, • Prior procedures & Tests • Back page • Current Study • Reference section • Designed to be completed in one minute or less

  7. METHODSSites of Pilot

  8. METHODSEnrollment Periods 3/1/08 8/15/08 10/15/08 2/28/09 SITE 1 2 3 4 5 6 1 SITE 2 3 4 5 6 Period 1 Period 2 Period 3 On-demand Report Paper Report

  9. RESULTSPatient Characteristics (n = 6,351)

  10. RISK ASSESSMENTAutomated Calculation and Indication Assignment SYMPTOMATIC PATIENTS (Diamond & Forrester) ASYMPTOMATIC PATIENTS (Framingham; CHD Risk)

  11. APPROPRIATENESS CLASSIFICATION(n = 6,351)

  12. APPROPRIATENESS CLASSIFICATION Elimination of Unclassified (n = 5,928)

  13. APPROPRIATENESS CLASSIFICATION Based on Site Inappropriate Range: 4-22% n = 578 1200 1448 1448 322 932

  14. APPROPRIATENESS CATEGORYBased on Patient Factors 9.8% 19.3% 13.6% 15.5% n = 3,046 2,882 3,468 2,460 p < 0.0001 p = 0.039

  15. MOST COMMON “INAPPROPRIATE” INDICATIONS

  16. APPROPRIATENESS CATEGORY Based on Referral p < 0.0001 13.2% 19.5% 16.1% 9.9% 70.7% 70.7% n = 4,792 n = 1,136

  17. APPROPRIATENESS CATEGORY Based on Referral p < 0.0001 13.2% 20.1% 16.0% 10.1% 70.9% 69.8% n = 4,881 n = 1,047

  18. FEEDBACK TO SITES

  19. INAPPROPRIATE SPECT-MPITemporal Changes Based on Site

  20. LIMITATIONS • Non-evaluable data • Missing information • Conflicting indications • Rolling recruitment with inconsistent time periods • Lack of validation of computer-assigned indications • Multiple indications • Audits reveal variance • Educational initiatives inconsistently applied • Non-adjudicated SPECT interpretations

  21. CONCLUSIONS • Data collection and analysis regarding appropriate use of SPECT imaging is feasible in busy community practice environment • Easy to use, point-of-ordering tool with web-based data entry • Automated determination of appropriateness • On-demand, benchmarked reports • Variable rates of test appropriateness • Consistent inappropriate indications • Asymptomatic, low risk patient are most frequent • Feedback/education may influence on practice habits • Less inappropriate testing from cardiologists than non-cardiologists

  22. IMPLICATIONS • Physicians and other health care professionals, working with medical societies, recognize the current healthcare environment and are taking active measures to optimize performance and cost-effectiveness, while preserving patient access to evaluation and treatment procedures • The development and implementation of AUC may offer an alternative to prior authorization/pre-certification approaches • Transparency • Expanded information regarding practice habits • Facilitation of on-going quality improvement • Movement toward point-of-order application • Potential for wide-scale utilization • Establishment of partnership between ACC, imaging subspeciality society, and health plan regarding responsible approach to medical imaging and continuing emphasis on improving the quality of care

  23. ACKNOWLEDGMENTS • American Society of Nuclear Cardiology (ASNC) • Support from UnitedHealthcare • Leadership of ACC • Especially Douglas Weaver, Ralph Brindis, Michael Wolk, Pamela Douglas, Jack Lewin, and Janet Wright • Staff from ACC, NCDR, and DCRI • Notably Joseph Allen, Karen Caruth, Wenqin Pan, and Nichole Kallas

More Related