Discover the history, working principles, and advantages of phonocardiography, and its role in modern healthcare. Learn about heart sounds, pioneers in auscultation, and the development of stethoscopes. Understand the functionalities of acoustic and electronic stethoscopes, and the acquisition of phonocardiographic signals. Explore the pros and cons of phonocardiography, and how it compares to echocardiography. Delve into a case study showcasing the application of phonocardiography in diagnosing heart conditions. Familiarize yourself with the mechanical processes of the heart that produce sound and indicate the individual's health status. Explore the significance of heart sounds like "lub" and "dub," understand the first and second heart sounds, and learn about the third heart sound associated with the diastolic filling period. Dive into the world of phonocardiography for a comprehensive understanding of this vital diagnostic tool.

loisyoung
Download Presentation

Exploring Phonocardiography: Heart Sounds & Advancements

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PHONOCARDIOGRAPHY Saumya Mohan Kumar T.E. Biomed-Roll No.55 Phonocardiography 12/20/2019 1

  2. Index Pioneers in auscultation Development of Stethoscope Development of Phonocardiograph Heart sounds Heart Murmurs Basic Block Diagram and Instrumentation Acquisition of phonocardiographic signals Writing methods for phonocardiography Pros and Cons Scope Echocardiography vs. Phonocardiography Case Study Phonocardiography 12/20/2019 2

  3. Pioneers Hippocrates laid the foundation for auscultation Robert Hook realized diagnostic use of cardiac auscultation Biggest breakthrough in auscultation: Rene Laennec invented stethoscope Dr. Jean Bennett Maguire devised a method of real-time spectral phonocardiography for the detection and classification of heart murmurs. Phonocardiography

  4. Way to heart is through ears…. Development of Stethoscopes Early monaural stethoscope Modern binaural stethoscope Modern electronic stethoscope Phonocardiography

  5. Working Acoustic stethoscopes transmit sound mechanically from a chest-piece via air filled hollow tubes to the listener's ears. The diaphragm and the bell work as two filters, transmitting higher frequency sounds and lower frequency sounds, respectively. Electronic stethoscopes function in a similar way, but the sound is converted to an electronic signal which is transmitted to the listener by wire. Functionalities often included in electronic stethoscopes are amplification of the signal, filters imitating the function of the diaphragm and the bell and in some cases recording abilities to allow storage of data. Phonocardiography

  6. Advantages Allow volume control of heart and lung sounds heard more easily without amplifying other sounds. Even subtle changes in breath sounds can be picked up and magnified Aid health-care professionals in hearing heart murmurs Electronic stethoscopes also allow the user to distinguish between body sounds of high and low frequency. They now have wireless capabilities, which allow data to be transferred to a computer or handheld device for storage and retrieval at a later time. Phonocardiography

  7. Disadvantages Patients undergoing surgery have the sterile field invaded thereby risking infection Patients are frequently awakened and disturbed Serious developmental abnormalities in newborn infants who are frequently disturbed In the absence of airtight seal between stethoscope and skin, which determines the quality of sound wave transmission, background noise is detected and physiologic sound transmission is impaired. They are not capable of generating constructive interference of physiologic sound waves. Phonocardiography

  8. Phonocardiograph- an intelligent Stethoscope Bioacoustic research Establish a relationship between mechanical event- conduction of heart- within the body and the sounds these events give rise to. The medical use of this knowledge is to link sounds that diverge from normality to certain pathological conditions. Phonocardiography

  9. Phonocardiograph: Instrument used for recording sounds connected with the pumping action of heart Phonocardiography

  10. Phonocardiogram: A high fedility recording representing the rhythmicity and heart rate Phonocardiography 12/20/2019 10

  11. Phonocardiography: the process of graphical recording of heart sounds or murmurs Phonocardiography

  12. Mechanical working processes of the heart produce sound which indicate health status of the individual. The relationship between blood volumes, pressures and flows within the heart determines the opening and closing of the heart valves. Normal heart sounds- lub and dub- occur during the closure of the valves. The valvular theory states that heart sounds emanate from a point sources located near the valves. In the cardiohemic theory the heart and the blood represent an interdependent system that vibrates as a whole and propagates sound as waves of alternate pressure. Heart Sounds Phonocardiography 12/20/2019 12

  13. First heart sound: • occurs when the atrioventricular (AV) valves closeat the beginning of ventricular contraction. • generated by the vibration of the blood and the ventricular wall • is louder, longer, more resonant than the second heart sound. Phonocardiography

  14. Phonocardiography

  15. Second heart sound - occurs when aortic and pulmonary semilunar valves close at the beginning of ventricular dilation - generated by the vibration of the blood and the aorta - Aortic valve closes slightly before pulmonary valve. Phonocardiography

  16. The second sound (S2) signals the end of systole and the beginning of diastole It is heard at the time of the closing of the aortic and pulmonary valves S2 is probably the result of oscillations in the cardiohemic system caused by deceleration and reversal of flow into the aorta and the pulmonary artery Phonocardiography

  17. A third heart sound (S3) connected with the diastolic filling period. The rapid filling phase starts with the opening of the semilunar valves. attributes energy released with the sudden deceleration of blood that enters the ventricle throughout this period A fourth heart sound (S4) connected with the late diastolic filling period occur during atrial systole where blood is forced into the ventricles. Phonocardiography

  18. Basic Heart Sounds in a Phonocardiogram Recording Phonocardiography

  19. Heart murmurs Murmurs are extra heart sounds that are produced as a result of turbulent blood flow which is sufficient to produce audible noise. Innocent murmurs are present in normal hearts without any heart disease. Pathologic Murmurs are as a result of various problems, such as narrowing or leaking of valves, or the presence of abnormal passages through which blood flows in or near the heart. Heart murmurs occur when the blood flow is accelerated above the Reynolds number, which induces non-stationary random vibrations, that are transmitted through the cardiac and thoracic tissues up to the surface of the thorax They are graded by intensity from I to VI. Grade I is very faint and heard only with special effort Grade VI is extremely loud and accompanied by a palpable thrill Phonocardiography

  20. Factors involved in production of murmurs Phonocardiography

  21. Heart Cycle Name Events 20 15 Pressure (kPa) 10 5 0 PCG ECG Phonocardiography Time 0 (sec) 0.4 0.8 0.3 0.5 0.6 0.7 0.1 0.2

  22. Basic Block Diagram Phonocardiography 12/20/2019 22

  23. Instrumentation Basic transducer  Amplifier  Filter  Piezoelectric sensor to convert sound or vibrations to electricity Crystal or moving coil microphone having frequency response between 5Hz and 1000Hz Similar response characteristics Offer selective high pass filter to allow frequency cutoff Bandwidth : 20- 2000Hz Amplify signal Permit selection of suitable frequency bands Avoid aliasing Separate louder low frequency signals from lower intensity, much informative high frequency murmurs. Phonocardiography 12/20/2019 23

  24. Integrator  Power Amplifier  DAC and Readout or high frequency chart recorder or  oscilloscope or headphones Recording envelope of higher frequency over 80Hz along with actual signals below 80Hz. Increase the power of incoming signal Efficiency is more Effect of noise is lowered Signal is converted to digital form and stored permanently For faithful recording of heart sounds Phonocardiography

  25. Sensors Sensors used when recording sound:  Microphones  Accelerometers These sensors have a high-frequency response that is quite adequate for body sounds. The microphone is an air coupled sensor that measure pressure waves induced by chest-wall movements The accelerometers are contact sensors which directly measures chest-wall movements For recording of body sounds,  condenser microphones  piezoelectric accelerometers have been recommended. Phonocardiography

  26. Acquisition of Phonocardiographic Signals Microphones picks up (i). Heart sounds (ii). Heart murmurs (iii). Extraneous noise in the immediate vicinity of the patient Group 1- (i) . Contact microphone (ii). Air coupled microphone Group 2- (i) Crystal microphone (ii) Dynamic microphone Phonocardiography

  27. Group 1 Microphones Contact Microphone also known as a pickup or a piezo microphone made of a thin piezoelectric ceramic round disc (+ve) glued to a thin brass or alloy metal disc (-ve) designed to transmit audio vibrations through solid objects. contact mics act as transducers which pick up vibrations and convert them into a voltage which can then be made audible. Phonocardiography

  28. Group 1 Microphones Air coupled Microphones shows a low-pass frequency response because of its air-chamber compliance. In the pass band, it is considered that the microphone has a flat response, where the mechanical impedance of air chamber is much higher than that of chest wall, the vibration of the measured chest-wall surface is stopped by both the air chamber and the coupler surface in contact with the chest wall. The sound pressure, or normal stress exerted on the chamber should be constant to keep a flat response. Phonocardiography

  29. Group 2 Microphones Crystal Microphones uses the piezoelectric effect of Rochelle salt, quartz, or other crystalline materials. This means that when mechanical stress, due to heart sounds, is placed upon the material, a voltage electromagnetic force is generated. Since Rochelle salt has the largest voltage output for a given mechanical stress, it is the most commonly used crystal in microphones. smaller in size, more sensitive than dynamic ones Phonocardiography

  30. a diaphragm that is mechanically linked to the crystal so that the sound waves are indirectly coupled to the crystal. a crystal is mounted so that the sound waves strike it directly Phonocardiography

  31. Group 2 Microphones Dynamic Microphones consists of a moving coil with fixed magnetic core inside. This moving coil moves with heart sounds, and produces voltage because of its interaction with magnetic flux Phonocardiography

  32. Technical design of Microphone It does not transform acoustic oscillations into electrical potentials uniformly for all frequencies. Hence heart sound recording done with microphone is valid for a particular type of frequency only.. Hence microphones of various types cannot be interchanged. Phonocardiography

  33. Writing methods for phonocardiography Requires a writing system capable of responding to 2000 Hz. Types of writing methods: (i). Mechanical Recorders (ii). Optical Galvanometric Recorders (iii). Envelope detection (iv). Direct recording using Ink Jet Recorders (v). Electrostatic Recorder (vi). Thermal Recorder Phonocardiography

  34. Ink Jet Recorders Merits very little loss of diagnostically important information eliminates the effort and delay of photographic processing immediacy of the results affords a means for continuously monitoring the records for quality and special content at the time of registration. Demerits writing recorders with an upper frequency response of 150 Hz cannot be used to write frequencies that lie beyond their working range. can only record heart sound intensity picked up every 10 msec. Phonocardiography

  35. Envelope Detection Uses artificial frequency of about 100 Hz in heart sound amplifier Employed to oscillate stylus so that high frequency sounds are modulated by 100Hz Phonocardiography

  36. Pros Can provide real-time traces of heart beats, movement and breathing. Taken together this can provide a unique view of cardiac condition. Passive, therefore inherently safe and can be used for long periods. Inherently cheap, (low data rates), and ideal for screening of large populations and home monitoring. simple, low cost, houses the necessary opto-electronic elements. and non-invasive PC-based system that is capable to process real time fetal phonocardiographic signal Cons Existing microphones are bulky and obtrusive Signal to noise ratio influenced motion artifacts Inherently 1 dimensional Extended instruments are intended for a pass band from 0.2 to100 Hz with nonlinear distortions to 10%. Recording of frequency components above this limit is related with an appreciable drop in amplitude of recording and an increase in distortions. The use of contacting transducers to sense the vibrations is inappropriate. Phonocardiography

  37. Scope Further Work 1. Design of clinical prototype 2. Improvements to signal conditioning and control electronics 3. Investigate wireless links for cordless monitoring 4. Remote measurement of small displacements at compliant surfaces Suggested Applications Remote sensing of sub 50 micron displacements Adult and fetal phonocardiography and phonography Remote measurements of compliant materials in wind-tunnels Infrasound intensity measurement Biomedical instrumentation Low-cost and low power confocal microscopy Cell culture measurement Phonocardiography

  38. Echocardiography better diagnosis of mitral valve defects ,evaluating the degree of its stenosis and characterizing the morphological changes of the valve. more informative about tricuspid valve defects echocardiographic data on the changes in the left ventricular outflow tract help to explain the origin of the spindle-form systolic murmur. Phonocardiography better diagnosing of mitral insufficiency, diagnosis of aortic valve defects more informative about state of aortic valves interpretation of systolic murmur was rather complicated, although they are often seen on phonocardiographic data of normal individuals and patients with heart diseases. The two not alternative, and the less contradictory, but mutually supplementing methods. Phonocardiography

  39. Case Study Phonocardiography

  40. Phonocardiography