400 likes | 463 Views
اساس اندازه گیری در سل کانتر. سل کانتر Orphee. Electrolytes solutions allow current to pass from them شرکت سپهر آنالیز. Electrolyte Like ISOTON III. www.labservice.ir. The CBC principle. A red cell passes through RBC aperture. Red Blood Cell. Sensing Zone. Oscilloscope.
E N D
Electrolytes solutions allow current to pass from them شرکت سپهر آنالیز Electrolyte Like ISOTON III
The CBC principle A red cell passes through RBC aperture Red Blood Cell Sensing Zone Oscilloscope Oscilloscope
The CBC principle A red cell passes through RBC aperture Red Blood Cell Sensing Zone Oscilloscope Oscilloscope
The CBC principle A red cell passes through RBC aperture Red Blood Cell Sensing Zone Oscilloscope Oscilloscope
The CBC principle A White cell passes through WBC aperture Neutrophil Oscilloscope Sensing Zone Oscilloscope
The CBC principle A White cell passes through WBC aperture Neutrophil Oscilloscope Sensing Zone Oscilloscope
The CBC principle A White cell passes through WBC aperture Neutrophil Oscilloscope Sensing Zone Oscilloscope
Passage of a RBC & Plt through aperture RBCs + - PLT Oscilloscope screen Cross section of RBC aperture (60x50 micron)
Passage of a RBC & Plt through aperture RBCs + - PLT Oscilloscope screen Cross section of RBC aperture (60x50 micron)
System without sweep flow RBCs recirculating + - RBC PLT Oscilloscope screen Sensing Zone
System without sweep flow RBCs recirculating + - RBC PLT Oscilloscope screen Sensing Zone
System without sweep flow RBCs recirculating + - RBC PLT Oscilloscope screen Sensing Zone
System without sweep flow RBCs recirculating + - RBC PLT Oscilloscope screen Sensing Zone
System without sweep flow RBCs recirculating + - RBC PLT Oscilloscope screen Sensing Zone
System without sweep flow RBCs recirculating + - RBC PLT Oscilloscope screen Sensing Zone
System without sweep flow RBCs recirculating + - RBC PLT Oscilloscope screen Sensing Zone
System without sweep flow RBCs recirculating + - RBC PLT Oscilloscope screen Sensing Zone
System without sweep flow RBCs recirculating + - RBC PLT Oscilloscope screen Sensing Zone
System without sweep flow RBCs recirculating + - RBC PLT Oscilloscope screen Sensing Zone
System with sweep flow RBCs pushed away by diluent + - RBC PLT Oscilloscope screen Sensing Zone Diluent stream
System with sweep flow RBCs pushed away by diluent + - RBC PLT Oscilloscope screen Sensing Zone Diluent stream
System with sweep flow RBCs pushed away by diluent + - RBC PLT Oscilloscope screen Sensing Zone Diluent stream
System with sweep flow RBCs pushed away by diluent + - RBC PLT Oscilloscope screen Sensing Zone Diluent stream
System with sweep flow RBCs pushed away by diluent + - RBC PLT Oscilloscope screen Sensing Zone Diluent stream
Sweep Flow technology RBCs swept away from sensing zone Diluent stream
Pulse editingCell flows through centre of aperture Good Pulse Diluent stream
Pulse editing Non central cell flow Pulse to be edited Diluent stream
Coincidence Correction Pulse to be edited Diluent stream
Applying Thresholdsto separate Plt from RBC 20 fl 2 fl Base line Platelets RBC of various sizes
RBC histogram Main RBC population RBC doublets 256 channel high resolution RBC histogram display cell population data between 24 and 350 fl
PLT histogram and curve fitting A fitted curve accurately reflecting the collected data is displayed between 2 and 35 fl Raw data Fitted Curve displayed up to 35fl PLT histogram is based on 64 channels
PLT curve fitting The Platelet count is derived from the number of cells under the fitted curve beyond the 35fl display limit extending up to 70 fl Raw data Fitted Curve extend up to 70 fl to report very large PLT count
PLT curve fitting The curve fitting process allows more accurate counts when platelets of larger than 20 fl are present
PLT curve fitting The curve fitting process allows more accurate counts when platelets of larger than 20 fl are present PLTs RBCs
Lymphocyte Monocyte Granulocyte CBC WBC histogram 256 channel high resolution WBC histogram display cell population data between 35 and 450 fl
Coulter WBC histogram Mono Lymp Neut Eos Baso
Hgb Measurement ADC Signal Processor WBC Bath HGB Lamp Derivation • Absorbance= log 10 ( VR / Vs ) • Where VR = Reference voltage • Vs = Sample voltage HGB Sensor & PRE-AMP Sample