1 / 19

Sentry Sampling Systems

Sentry Sampling Systems. Sentry Equipment Corp. Sentry Sampling Systems. Over 25 systems manufacturers worldwide Centralized stations are very common >6 Sample Lines- Standard Conditioning Rack <6 Sample Lines- Single Line Panels

lowell
Download Presentation

Sentry Sampling Systems

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Sentry SamplingSystems Sentry Equipment Corp.

  2. Sentry Sampling Systems • Over 25 systems manufacturers worldwide • Centralized stations are very common • >6 Sample Lines- Standard Conditioning Rack • <6 Sample Lines- Single Line Panels • Very Competitive Business- Allows spare parts business in the future

  3. Sentry Standard Conditioning Rack Design • Constant flow • Efficient sample conditioning • Efficient use of space and custom designs • Highest Performance Components in the Marketplace • 304SS front on conditioning section • Dedicated secondary coolers with close approach temperature

  4. Sampling Systems

  5. Sampling Systems

  6. Sampling Systems

  7. Common Problems Solved withSentry Sampling Systems

  8. Problem #1: Non-constant Flow to Analyzers • Sentry VREL and BPR/RV in Tandem • VREL Reduces Bulk of Pressure • BPR/RV Does Fine Pressure Control • Shock Absorber- Extra Flow through BPR/RV • Flat Flow vs. Pressure Curve

  9. Problem #2: Poor Sample Temperature Control • Competitor’s Bath Systems are not “Isothermal” • Competitor’s Bath Systems typically only cool • Bath has Poor Approach Temperature due to Low Turbulence • Sentry System uses Dedicated Secondary Coolers • High Surface Area- Close Approach Temperature • +/- 0.25 C control with Chiller; 25+/- 0.5 C through Sentry Coolers

  10. Problem #3: Plugging Sample Lines • Typically caused by Oversized Sample Lines • Also Caused by Low Flow • Sentry Properly Sizes Coolers with Cooler Program • Sentry Recommends Low Pressure Blowdown

  11. Problem #4: Samples Too Hot • Many Times Competitor’s Coolers are Undersized • Computer Sizing Can Eliminate • Sentry has over 30 Cooler Models, Competitors have 2 to 4 models • Sentry models include 0.11, 0.16, 0.22, 0.33, & 0.44 Square Meter Surface Area

  12. Problem #5: Rusting/Patched Panel Front • Most Competitor’s Panels have Painted Carbon Steel Fronts • Sentry Panel has Corrosion Resistant Modular 304 SS Front • Modular Front Allows Future Changes Without Patching the Panel Front

  13. Problem #6: Too Low Sample Flow • Competitor’s Don’t Size Coolers Properly • Steam Samples, Especially Low Pressure Steam, Needs High Capacity Sample Cooler • Sentry has Special High Surface Area/Low Pressure Drop Coolers- FLF-6222/FXF-6223

  14. Problem #7: Thermal Excursions • Thermal excursions can cause operator injury, damage cells, analyzers and other components and discharge of steam to atmosphere • Thermal excursions can be caused by loss of cooling water, high sample flow rate, fouled or plugged sample cooler or high cooling water temperature • Thermal Shut Off Valves - requires no pneumatic or electrical power, re-settable latching design, positive position indication, compact package • Optional switch for remote indication

  15. Problem #8: Multiple Independent Analyzers • Calibration differences can occur between independent analyzers • Calibration requires valuable time • Sharing one analyzer reduces calibration differences, calibration time, consumable usage, capital cost • Sentry Sequencer is a proven method of analyzer sharing

  16. Kinds of Projects • Complete Turnkey • Panel Upgrade with Components • Some Local Content- Conditioning by Sentry/Analyzers Supplied Locally

  17. Get Sentry Specified • Sentry Panel Specification • Specify Sentry Components • Require Dedicated Secondary Coolers • Require Flanged, single gasket, 304 SS shell, 304 SS Bolts, and 316 SS Tubing • Require Sentry VREL on High Pressure Lines (> 35 Barg) • Require Sentry TSV & BPR/RV

  18. Sentry Sampling Systems Set the World Standard for Quality and Performance