350 likes | 667 Views
ABB standard drive Enhanced ACS550. ACS550, Standard Drive. ABB Standard Drive Part of the family - The ABB Drive Reliable quality product Global support Convenient with all the aspects Simple selection Excellence in connectivity Intuitive drive All inside as standard
E N D
ACS550, Standard Drive ABB Standard Drive • Part of the family - The ABB Drive • Reliable quality product • Global support • Convenient with all the aspects • Simple selection • Excellence in connectivity • Intuitive drive • All inside as standard • Proven Performance
0,75 to 5,5 kW up to 11 kW up to 22 kW up to 45 kW up to 55 kW up to 132 kW up to 160 kW up to 355 kW ACS550, Standard Drive • Complete power range • 0.75 - 355 kW, 1 - 500 HP • 3 phase 230 V (up to 75 kW) and 400 V series • IP21 / UL Type 1 • IP54 / UL Type 12 (R1-R6 only)
ACS550, Standard Drive Installation • 550-01 Mounting options • Wall • Side-by-Side • Flange • 550-02 Mounting options • Free standing • Side-by side
Convenience with all the aspects Selection Connectivity Performance Intuitive All inside
ACS550 – Selection • Type code shows output current and input voltage • Control options can be ordered using plus codes or as separate option kits ACS550-01-06A9- 4+L511+K451 Input Voltage 380 to 480 V Relay Output Extension +L511 Output Current 6.9 A DeviceNet Adapter +K451
ACS550 – Selection ACS550 ratings
ACS550 – Selection R1 R2 R3 R4 369 469 583 689 212 125 222 125 231 203 262 203 Dimensions are in [mm]
ACS550 – Selection R8 R7 R5 R6 739 880 1507 2024 286 265 400 300 520 250 617 347 Dimensions are in [mm]
ACS550 - Connectivity • Easy connection to factory automation systems through multiple I/Os and plug-in options • Extensive I/O • 2 x AI • 2 x AO • 6 x DI • 3 x RO Inbuilt Modbus Plug-in Fieldbus Modules Relay Output Extension (3 x RO)
ACS550 - Connectivity • IO is galvanic isolated as groups AI / AO DI RO
ACS550 - Connectivity • 550 supports the new parameterization tool FlashDrop • For selecting and setting parameters • Parameter set for non-connected drive • In warehouse or during mechanical installation • Possibility to hide selected parameters • Machine protection • Only essential parameters are shown • FlashDrop connection behind the control panel - protection class will remain
ACS550 - Connectivity • All FBs are either embedded or mechanically installed inside the drive • Modbus is the embedded fieldbus • ACS 800 type Fieldbus modules are used to provide remaining FBs • Available fieldbuses: • PROFIBUS • DeviceNet • LonWorks • ControlNet • CANopen • Ethernet (Modbus TCP & Ethernet/IP)
ACS550 - Intuitive • Assistant control panel functions • Run the assistants in conjunction with drive software • Has help button giving manual information • List of changed parameters • Real time clock • Fault Logger • 15 languages supported in one panel
ACS550 - Intuitive • Basic control panel • 7 segment display • Implement panel protocol to display and modify parameters • Upload or download capabilities • Backlight
ACS550 - Intuitive • Buttons of the Assistant control panel: Soft key 1 function Soft key 2 Function Soft key 1 Soft key 2 Loc / Rem mode Help button Start button Stop button Up and down buttons (to change parameters and their values)
ACS550 - Intuitive Assistants in the panel • Start - Up assistant guides the user through all essential settings to be done without going directly into the parameter list. • Maintenance assistant can set the drive a criteria to insert preventive maintenance. • Timer Assistant helps in using timed functions • Serial Communication Assistant for making fieldbus setup simple and easy • PID Assistant for feedback scaling and setting • Drive Optimizer to optimize the drive in different aspects • Noise • Efficiency • Motor control performance
ACS550 - Intuitive Fault Logger (Assistant panel only) Easy way to find out • What happened • When happened • Tells drive status at the point of time the fault occurred • Frequency, speed, torque, current, voltage etc… • Example: Panel Loss – fault 10 • Panel tells the operator to “check: comm lines and connections, parameter 3002, parameters in groups 10 and 11”
ACS550 - Intuitive • DriveWindow Light 2 • For commissioning the drive • Possibility to monitor the drive • Assistant to create direct configuration of the drive • Remains compatible to other Low Voltage AC Drive products
ACS550 - All inside • …And ACS550 • The old way to do it... Braking chopper input choke • Built-in: • RFI filter, input choke, braking chopper (R1&R2), Modbus • (other fieldbuses as internal plug-in options) EMC filter
ACS550 - All inside ACS550 internal options Assistant control panel (as standard) Basic control panel Relay Output Extension Module Plug-in Fieldbus
ACS550 – All inside EMC filter • Cable lengths for 1st environment 75 – 300 m • Cable lengths for 2nd environment 100 – 300 m • Detailed table on cable lengths available • EMC environment explanation
ACS550 – All inside • New way to suppress harmonics caused by the inverter “swinging choke” • At partial load the swinging choke reactance increases • THD reduction up to 24.2% compared to traditional choke
ACS550 – All inside • “Swinging Choke” • Designed to reduce harmonics at full and partial loads • Perfect for Variable Torque Centrifugal Loads
ACS550 – Performance • Sensorless vector control • Up to 12 kHz switching frequency at reduced current for R1-R4 • Automatic noise reduction • Switching frequency goes up when load decreases • Noise smoothing function • Motor thermistor input (both PT 100 and PTC) • Two independent PIDs • On - Off controlled cooling fan
ACS550 – Performance • Scalar control for easy start-up and multi-motor applications • Sensorless Vector providing very good performance Step load response (Dynamic accuracy) Vector Control 0.9 0.8 0.7 0.6 ACS550 0.5 Stiffness [%s] Competitor A 0.4 Competitor B 0.3 0.2 0.1 0 150 750 1500 Speed [rpm]
Convenience with all the aspects Selection Connectivity Performance Intuitive All inside