1 / 38

Hybrid Analysis with the Pierre Auger Observatory

Recontres de Moriond. Hybrid Analysis with the Pierre Auger Observatory. David Newton University of Leeds dn@ast.leeds.ac.uk. La Thuile, March 2005. Measured Energy Spectrum. Summary of some of the problems with the energy spectrum:. At low energies SD apertures can be in error

luyu
Download Presentation

Hybrid Analysis with the Pierre Auger Observatory

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recontres de Moriond Hybrid Analysis with the Pierre Auger Observatory David Newton University of Leeds dn@ast.leeds.ac.uk La Thuile, March 2005

  2. Measured Energy Spectrum

  3. Summary of some of the problems with the energy spectrum: • At low energies SD apertures can be in error • At high energies FD apertures are uncertain • Model/mass uncertainties in conversion from SD • Fluorescence Yield • Absolute calibrations of FD and SD BUT: EVENTS ABOVE 100 EeV DO EXIST

  4. The Hybrid Concept 300-400 nm light from de- excitation of atmospheric nitrogen (fluorescence light) Fluorescence Detector • Energy + longitudinal development • Time -> direction Surface Detector • Shower size ->Energy • Time -> direction

  5. Hybrid Reconstruction Using timing from one station + FD data gives angular reconstruction equivalent to stereo detection

  6. Hybrid events equivalent to stereo events and superior to mono events

  7. Hybrid Benefits • Gives 2 independent energy measurements • Only SD timings are used in geometric reconstruction. SD signals are independent and can be used to calculate separate energy measurement • Cross check of energy measurements • identify systematics in each technique • 10 % duty cycle, but... • Use quality hybrid events to 'train' the SD events • Gives high quality SD events with 100 % duty cycle

  8. Hybrid Benefits... • Calibration can work both ways • Low quality FD events ( large atmospheric attenuation uncertainty) can use the SD energy to normalise the longitudinal profile • All FD events will be hybrid • Easy to compute aperture • Low energy threshold • Only require timing information from 1 SD station • High resolution measurements down to 1 EeV

  9. Hybrid Benefits... • Combine FD and SD parameters used for primary identification. • Xmax , LDF slope parameter , Muon Ratio, FADC analysis...

  10. A tour through event 673411. A hybrid event and a stereo event (nearly). Here is what one finds on the SD event display. From Coi-hueco-> From Los Leones->

  11. Fluorescence Display Event 673411 Coi-hueco (6 pixels) Los Leones (29 pixels)

  12. Event 673411 Hybrid Reconstruction Mono fit Hybrid fit <- SD times <- SD times <- FD times <- FD times Hybrid (Los Leones) Surface Difference Easting 465960 ± 80 465830 130 m Northing 6090234 ± 20 6090308 -74 m Theta 36.7 deg 35.9 deg 0.8 deg Phi 185.8 deg 186.7 deg -0.9 deg

  13. Event 673411 Nemaximum = 1.4x1010 Nemaximum ~ 7x1010for energy = 1020 eV FD energy~ 2x1019 eV (preliminary) SD energy= 2.1x1019 eV

  14. Summary... • Data taking and analysis in conjunction with installation and calibration • Hybrid observations will give high statistics, high quality events • Unambiguously determine the cosmic ray spectrum above 1018 eV • structure of the ankle • GZK features • Primary identification.

  15. Balloon launches (p, T, Humidity..) Horizontal Attenuation Monitor Measurements at Malargue of the deviation of grams/cm2 with respect to US std atmosphere Measurement of horizontal attenuation of the atmosphere at the Auger site. Attenuation varies between 8 km and 18.5 km

  16. Atmospheric monitoring One steerable LIDAR / Eye • during data taking • “Shoot the shower” • Raman LIDAR Backscattered light r T ~ e-β(r)

  17. Bad night Average night VAOD = Vertical Aerosol Optical Depth 26 km <- Celeste Central Laser Facility (vertical beam + optical fibre to Celeste)

  18. Event 721353

  19. Hybrid Benefits... Primary Identification – Plot of Xmax v N(muon) for simulated Iron and proton primaries Diagonal line on 2D scatter plot, gives better separation of proton/iron components than relying on Xmax or N(muon) alone. Could use additional information (risetimes, LDF ...)

  20. Knee

  21. Surface Detectors • Energy calculation is model dependent – systematic uncertainty • Aperture is generally easy to calculate • although problematic at threshold energy

  22. PAO Status • 12 Fluorescence Telescopes fully operational • ~ 700 + surface detectors operational • Completion of Observatory in early 2006 • Data taking and analysis in conjunction with installation and calibration • First results – August 2005

  23. Fluorescence Detectors • Energy Measurement is calorimetric – model independent, but... • Need constant calibration of optics, electronics... • atmospheric modelling • light attenuation, re-scattered light from aerosol, Rayleigh scattering • Aperture is difficult to calculate • especially at high energy

  24. FD Calibration light flux measured by absolutely calibrated PMT light diffusing Tyvek walls Drum: uniform camera illumination pulsed light sources, several wavelengths and intensity

  25. Absolute calibration with the drum pixel FADC trace CCD image of the drum drum calibration: camera shadow, mirror reflectivity, mercedes, PMT sensitivity, etc., are all included! 1 FADC count ≈ 4 photons at the diaphragm

  26. Infrared Cloud Monitor Estimate “cloud fraction” / FD camera pixel Coihueco Los Leones

  27. Extensive Air Showers 1018 eV < E < 1021++ eV

  28. Why Do We Study High EnergyCosmic Rays? • Offer a unique window on the ultra high energy universe • No known acceleration mechanism beyond 1015 eV • Predicted Greisen-Zatsepin-Kuzmin (GZK) steepening? • p + g2.7K -> D+-> p + p0 -> n + p+ • If E > 4 x 1019 eV 50% from within 130 Mpc • If E > 1020 eV 50% from within 20 Mpc

  29. We'd Like to Know... • Where they come from. • Discrete sources? • Anisotropies? • Isotropic? • Extragalactic? • What they are? • Nature of the primary • The shape of the energy spectrum

  30. Surface Detectors • Angular reconstruction from fit of the shower front to the detector trigger times • Fit Lateral Distribution Function to get ground parameter -> energy(models)

  31. Fluorescence Detectors Angular Reconstruction Stereo detection (2 telescopes) improves the angular reconstruction

  32. Fluorescence Detectors Energy reconstruction... Energy found by integrating under the curve

  33. The Observatory • 3000 km2 on completion • FD eye (4 peripheral eyes, 6 telescopes each) 11000 PMTs • 1600 SD Cerenkov tanks (spacing 1.5 km) 4800 PMTs

  34. The Surface Detectors

  35. The Fluorescence Telescope The Camera:440 PMTs on a spherical surface

  36. The Schmidt optics Spherical aberration Coma aberration C C F C spot Diaphragm Coma eliminated C Spherical focal surface

  37. The FD camera Production and test of all PMTs completed, failures at 1 ‰ level Light collectors to recover border inefficiencies “mercedes star” with aluminized mylar reflecting walls 440 PMTs on a spherical surface 90 cm

More Related