1 / 27

NXIO 介绍 f r om “OEMax NXIO Introduction CN rev4”

NXIO 介绍 f r om “OEMax NXIO Introduction CN rev4.ppt”. Thomas Sugimoto Strategic Marketing Manager. 议题. PLC I/O 市场趋势 分布式 I/O 的诞生 NXIO 第 2 代分布式 I/O 设计 产品概况 目标市场 如何使用 NXIO 来降低成本 内部最优化的品质. PLC I/O Trends 市场趋势. PLC I/O 市场趋势.

lynne
Download Presentation

NXIO 介绍 f r om “OEMax NXIO Introduction CN rev4”

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NXIO 介绍from “OEMax NXIO Introduction CN rev4.ppt” Thomas Sugimoto Strategic Marketing Manager

  2. 议题 • PLC I/O 市场趋势 • 分布式 I/O的诞生 • NXIO 第2代分布式 I/O 设计 • 产品概况 • 目标市场 • 如何使用 NXIO来降低成本 • 内部最优化的品质

  3. PLC I/O Trends 市场趋势

  4. PLC I/O 市场趋势 • Large End Users and Complex OEMs are looking for ways to further reduce their costs • Hardware PLC and I/O costs keep decreasing so now Space, Labor and Maintenance of I/O Wiring is becoming a major cost • Networked I/O Trend PLC HW COSTS - DOWN SPACE, WIRING COSTS - UP Large Factories - Refineries - Automotive Complex Machine OEMs

  5. PLC I/O 市场趋势 • Customers purchasing I/O as a Component • Customers can buy any PLC Controller and use any I/O platform due to emergence of Global Network Standards (e.g. Profibus, DeviceNet) • e.g. Controller is Brand ZZZ and I/O is OE Max NXIO OE MAX Controls OE Max Controls Bridge Brand AAA Servo NX PLC NXIO Brand ZZZ

  6. “分布式 I/O” 概念的诞生

  7. 我从改善PLC I/O • Birth of “Distributed I/O” Concept to reduce Wiring costs • Combination of Network + Modular I/O + Terminal Block (TB) • Network provides Diagnostic Data back to Controller for easy Maintenance Distributed I/O PLC Controller Network Master Network Slave I/O I/O I/O I/O TB TB TB TB Network Slave I/O I/O I/O I/O TB TB TB TB

  8. 我从改善PLC I/O • Popular for over 10yrs in North America and Europe where space and labor are very expensive • Trend will continue into China • Growing Number of Large Factories (e.g. Automotive, Food and Beverage) with Networking Requirements • Labor and Space Costs will increase over time • Productivity (not just low cost labor) will become a Competitive Advantage • Many Terminal Block or Sensor Suppliers start to sell Distributed I/O platforms • WAGO, Phoenix Contact, Beckhoff, Turck, Opto22 but they lack a PLC background

  9. NXIO 第2代分布式I/O设计

  10. PLC I/O 市场趋势 • The trend for the Semiconductor OEMs is to adopt Distributed I/O • DeviceNet is adopted as a Semiconductor Standard and has become very popular in Asia and North America • Saves on space and wiring • OE Max Controls launches NXIO in 2004 • 2nd Generation Distributed I/O Design • Slice-type with high granularity of I/O

  11. NXIO Specifications 产品概况

  12. 产品概况 • Save space • Small Footprint • 1, 2, 4, 8, 16 point I/O Modules • Expansion up to 32 slots • Various I/O Types • Discrete I/O: 24Vdc, Relay, Triac, SSR • Analog I/O: Current and Voltage • Thermo-couple, RTD input • High Speed Counter

  13. 产品概况 • Easy to use • Protected Output • Removable Terminal Block • Easy wiring • Network Connectivity • DeviceNet • Profibus-DP • Others: CanOpen, EtherNet/IP • Certifications • CE, UL, cTick

  14. 控制规格

  15. 特征和功能 Sliding expansion Color Code Communication Status Removable Terminal Block I/O Status LED One-Touch Wiring Test Pin * * * * Din-Rail & Frame Ground 3 wire device 2 wired device COM connection Din-Rail Lock Field power

  16. 特征和功能 • Removable terminal block • One-Touch Cabling without Screw Driver • Separated field power • Easy wiring for COM connection • I/O Status LED • Module identifier by color coding • Test pin for Easy and Safe operation • Sliding I/O expansion without Screw Driver • DIN-rail installation • Frame Ground to enhance noise immunity Easy Wiring Faster maintenance Enhanced Structure

  17. 目标市场 • 分布式 I/O 不是仅针对某个应用和工业行业的 • 无论哪里你需要联网的I/O,你就可以使用 NXIO

  18. 目标网络市场 • DeviceNet Market • Save space (network power for sensors) • Motor Control Centers (overload diagnostics) • Semiconductor, Electronics Industry • Profibus DP Market • Cost Reduction from using Siemens ET200 I/O • High Performance • SCADA (Supervisory Control and Data Acquisition) • DCS (Process Control – Distributed Control System) • Outdoor Applications (-20C to 55C Rating) • Future: Modbus TCP (Ethernet), Modbus Plus

  19. PC 目标控制方案 Large Variety of Control Solutions • PLC • PC Based • Soft PLC • Web Based • VME Controller • Compact PCI • HMI

  20. Advantages of using NXIO 如何使用 NXIO来降低成本 - 同时通过改进的接线方式使你的系统增值

  21. 降低你的PLC硬件总成本 • Easy way to lower Total HW Cost is to use NXIO with your current Control Solution • Keeping same PLC minimizes redesign of system • Cost Reduction Example • Continue to use Siemens S7-315DP Controller with Profibus • Replace Siemens ET-200 I/O (typically M or S series) with NXIO Profibus Network S7-200M (S7-300) + Terminal Block • NXIO • Smaller • Easier to wire • Lower Cost S7-315DP Controller

  22. 降低你的人力成本 • Internal Field Power Bus eliminates extra Wires for Commons • Reduces wiring by over 25% • Reduces wiring mistakes • Special Modules available for wiring Analog Shields • No extra terminal blocks needed for wiring • NXIO is a Terminal Block • “Spring Clamp” Terminal Block design eliminates need for Screwdriver • Guarantees good connection even under vibration

  23. 消除浪费的 I/O 点数 • With Traditional PLC I/O platforms, I/O Points and Space can be wasted • e.g. Need 480pts of Digital I/O but only 2 Analog I/O and 1 High Speed Counter • NXIO is highly configurable • 16pt Digital I/O • 1 Channel HSC • 2 Channel Analog This lowers HW costs and saves Cabinet Space NXIO 16pt Module Smaller Size Typical PLC 16pt I/O Module

  24. 内部最优化的品质 -让我们看看 OE Max NXIO内部有什么

  25. 连接类型 “Press fit” structure provides superior vibration resistance OE Max WAGO/BeckHoff (Press fit type) (Contact Type)

  26. 背板通讯 • Reduced hardware cost by serial communication. • Efficient protocol for rapid response time – Change of State Inputs Service Message Frame Message Header Message Length Function Code Service Data Field CRC 8 I/O Message Frame Message Header Message Length I/O Data Field CRC 8 Input Token Adapter Input Data sent using Change of State when Token is received ‘1 ‘6 ‘2 ‘3 ‘4 ‘5 1 2 3 4 5 Slot#2 Slot#3 Slot#4 Slot#5 Slot#6 Slot#1 Output Data by Broadcasting

  27. TM SM Maximum Value for OEMs