CLEO-III Trigger Systematic Studies Progress Report – M. Selen

CLEO-III Trigger Systematic Studies Progress Report – M. Selen. Axial Tracking Study more or less completed Work done by Inga Karliner (build on work by Randal Hans) Bottom line: Efficiency for PT>200 MeV ~ 99.9% Stereo Tracking A natural extension of the above

magnar
Download Presentation

CLEO-III Trigger Systematic Studies Progress Report – M. Selen

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CLEO-III TriggerSystematic StudiesProgress Report – M. Selen • Axial Tracking • Study more or less completed • Work done by Inga Karliner (build on work by Randal Hans) • Bottom line: Efficiency for PT>200 MeV ~ 99.9% • Stereo Tracking • A natural extension of the above • Studies done by Charles & Randal have shown this is also extremely efficient. We will quantify this soon. • Calorimeter • Work proceeding in || with CLEO-c sharing (show some plots). • Studies done by Topher Cawlfield (build on work by Jesse Ernst) • Timing • This was “tuned” when the trigger was commissioned. • Will quantify after calorimeter turn-on study.

  2. Mixer/Shaper Crates (24) Drift Chamber Crates Gates CLEO Mixer/Shaper Boards ctrl. DR3 - TQT G / CAL TILE (16) AXTR(16) AXX(16) Flow control & Gating DFC DAQ ASUM Analog TIM TIM Barrel CC Axial tracker QVME DM/CTL DM/CTL TILE(8) STTR(12) L1D ASUM Stereo tracker Endcap CC QVME TIM DM/CTL Level 1 decision AXPR TRCR CCGL TRCR CC Digital TPRO(4) TIM SURF SURF TPRO(2) DM/CTL TCTL TIM DM/CTL CLEO-III/cTriggerSystemOverview

  3. Layer 9 = “key” InnerLookup OuterLookup Inner/Outer track correlator

  4. “Hadron” “Electron” Tracking Systematic Study • Approach: • Look at CLEO-III Data-5 through Data-16 • Select events that pass EL-track line • (#AX>0)&(#CBmd>0)&(AX+CB time) • Select by L3 classification • Loop over “good” reconstructed tracks (c2/dof<3.5, d0<1.5cm, etc…) • Ignore highest momentum track (assume it caused trigger) • Examine trigger status of all other tracks (did it “pass” or not)

  5. To see if a track “passes” trigger: • Extrapolate fit back to layer 9 to see which of the 112 key wires should be asserted. • See if the track-finding hardware for this wire, or either of its immediate neighbors, reports a correlated track. • A track is called “Isolated” if there are no other tracks within ±5 key wires. • If trigger does not fire,see if its because of: • Missing hits (OK) • Hardware (BAD) • Study as a function oftracks PT and cos(q)

  6. No Trigger - hardware “Isolated Tracks” In Electron Events All Tracks PT 1/PT 1/PT No Trigger -missing hits 200 MeV Total Efficiency 1/PT 1/PT

  7. No Trigger - hardware All Tracks “Isolated Tracks” In Hadron Events PT 1/PT 1/PT No Trigger -missing hits 200 MeV Total Efficiency 1/PT 1/PT

  8. No Trigger - hardware All Tracks “Non-Isolated Tracks” In Hadron Events PT 1/PT 1/PT No Trigger -missing hits 200 MeV Total Efficiency 1/PT 1/PT

  9. cos(q) cos(q) cos(q) cos(q) No Trigger - hardware All Tracks “Isolated Tracks” In Electron Events Cos(q)(PT > 200 MeV) No Trigger -missing hits Total Efficiency

  10. cos(q) cos(q) cos(q) cos(q) No Trigger - hardware “Isolated Tracks” In Hadron Events All Tracks Cos(q)(PT > 200 MeV) No Trigger -missing hits Total Efficiency

  11. cos(q) cos(q) cos(q) cos(q) No Trigger - hardware “Non-Isolated Tracks” In Hadron Events All Tracks Cos(q)(PT > 200 MeV) No Trigger -missing hits Total Efficiency

  12. Axial Tracking Summary: • For PT > 200 MeV we lose the following due to missing hits: • 1 of 41,500 isolated electron tracks • 13 of 10,500 isolated hadron tracks • 1 of 4,100 non-isolated hadron tracks • Overall efficiency > 99.9% • We don’t lose any tracks due to “missing hardware”.

  13. Axial Raw key wires 112 Clustered key wires 112 Axial matching cells 48 Stereo - U 48 high 48 low Stereo - V 48 high 48 low high low high Stereo Tracking

  14. 1.0 Needtostudy .8 .6 .4 .2 Topher’s study of CC “turnon” behavior

  15. CC time – TR time LOW Time Bucket 5 20 10 15 10 20 MED 30 40 Key Wire 50 60 HIGH 70 80 90 100 110 #track Ev-time Timing Issues

  16. Summary & Plan • Axial Tracking Trigger studies more or less finished • Efficiency >= 99.9% for PT > 200 MeV • Stereo Tracking study is next • Expect similar results • Calorimeter studies also under way • Understand turn-on behavior for each TIXEL • Threshold, Width, Max-efficiency • Also needed for MC • Must include sharing. This is non-trivial. • Timing is an issue that still needs to be addressed • TR relative to CC • Overall efficiency