I used the file Luis supplied for a 250GeV beam which was created using a 10x10x500 m m mesh.

I used the file Luis supplied for a 250GeV beam which was created using a 10x10x500 m m mesh. Geometry of the model was 1000 m mx100 m mx3cm. A mesh of 20x20x120 m m. I couldn’t use the same mesh size as Luis because that large an aspect ratio would cause the elements to fail shape testing.

maia-tucker
Download Presentation

I used the file Luis supplied for a 250GeV beam which was created using a 10x10x500 m m mesh.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. I used the file Luis supplied for a 250GeV beam which was created using a 10x10x500mm mesh. • Geometry of the model was 1000mmx100mmx3cm. • A mesh of 20x20x120mm. • I couldn’t use the same mesh size as Luis because that large an aspect ratio would cause the elements to fail shape testing. • To fit more elements along the z axis I had to reduce the number in x and y.

  2. Due to the amount of elements being used, I decided to conduct only a thermal analysis, initially. • This will enable me to use Luis’ temperature rise figures as a benchmark.

  3. One bunch • The maximum temperature rise after 1 bunch was 233.32°C. Slice along the x-z plane at y=5mm

  4. 2 bunches • Max. temp 466.217°C.

  5. Hot Zone in greater detail In future I will refine the mesh in this region and have a courser mesh over the bulk of the volume.

  6. Hottest Node v. Time

  7. Mesh Sizes • Prior to using the 20x20x120mm mesh (62500 elements), a relatively course mesh of 100x100x500mm was used (500 elements). • This allowed testing of boundary conditions and time step regimes etc. without being computationally expensive. • This led to temperature rises of only ~11°C per bunch as opposed to ~230 °C on the more refined mesh. • Previous meshes used for the entire collimator have been of the order of 6mm.

  8. Coupled Field Analysis • The simulation was repeated using SOLID5 coupled field elements. One bunch, Temperature rise of 221.654 °C. A difference of 10.666 °C compared to using thermal elements.

  9. 2nd Bunch • Max temp 448.729 °C, difference of 17.488 °C.

  10. Hottest Node v. time The hottest node was the same in each case. Although the maximum temperature was slightly different, they both displayed a very similar pattern.

  11. Stress at one element v. time • Chose the element which contained the node that reached the highest temperature. • Red crosses indicate time steps • High concentration of crosses at the 0s & 337ns time steps show where the heat loads were applied.

  12. Stress at one element v. time

  13. Maximum indicated stress is 735MPa. • I have figures of UTS 950MPa and Yield Stress 880MPa for this alloy. • Unfortunately these are room temperature figures. I haven’t been able to find data for elevated temperatures. • The time between steps could be too large and data points. • Some higher stresses could have been missed. • I will perform further analysis to check the time steps immediately after a beam impact.