1 / 36

Zn + Cu 2 +  Zn 2 + + Cu

Zn + Cu 2 +  Zn 2 + + Cu. Applied Electrochemistry. Voltaic (or galvanic) cells: spontaneous redox reaction  electricity (or electrical work) Electrolytic cells: non-spontaneous electricity  redox

Download Presentation

Zn + Cu 2 +  Zn 2 + + Cu

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Zn + Cu2+ Zn2+ + Cu

  2. Applied Electrochemistry • Voltaic (or galvanic) cells: spontaneous • redox reaction  electricity (or electrical work) • Electrolytic cells: non-spontaneous • electricity  redox • To produce electricity, we must direct the electron flow through an external circuit. We cannot have direct redox. • Daniell cell Zn – Cu rxn:

  3. Lemon Battery

  4. 17.1 Galvanic Cells 3:25

  5. Galvanic Cells • To produce electricity, we need: • Isolated half-reactions, using half-cells • Conductive solids (electrodes) connected by external circuits • May consist of a reactant/product or be an inert substance such as platinum or graphite • Anode: oxidation half-reaction • Cathode: reduction half-reaction

  6. Galvanic Cells

  7. Galvanic Cells • Externally, the anode has the negative charge; internally, it has a positive charge • Anions flow towards the anode; cations move away from it and towards the cathode. • Two half-cells must be connected to pass ions • Salt bridge or porous glass

  8. Molecular View of Electrode Processes

  9. 17.2 Cell Potentials • If the half-reactions are carried out separately (but coupled), we find they generate an electrical current characterized by a voltage

  10. Cell Potentials • The voltage produced by a voltaic cell is called the cell potential, Eocell (also the reaction potential, Eorxn, when the half-reactions are not separated) • Under standard conditions, the voltage is also called the standard electromotive force (emf), Eo. • Unit = Volt (V) • Volt = 1 Joule of energy / coulomb of charge transferred = 1 J/C • J = Joule C = coulomb • 1 mol e- = 96,500 coulombs

  11. Cell Potentials • Reference for Eo is the standard hydrogen electrode, using the reaction: • 2H+(aq) + 2e- H2(g) Eo = 0 V = 0 J/C 1 M 1 atm (std conditions)

  12. Cell Potentials • Then get other half-reaction potentials from measured Eocell values. • Zn + 2H+ Zn2+ + H2 Eocell = 0.76 V • Zn  Zn2+ + 2e- Eoox = 0.76 V • 2H+ + 2e- H2 Eored = 0.00 V • How do these reactions relate?

  13. Cell Potentials • Cell potential values can thus be determined relative to the standard hydrogen electrode, with Eo = 0 V • Eored = cell potential for the reduction half-rxn • Eoox = cell potential for the oxidation half-rxn • Thus, Eocell = Eored + Eoox • We can measure Eocell, using the standard reference of 0 V, we can measure Eoox and Eored for half reactions paired with the H2 half reaction.

  14. Determining Cell Potentials Values • If we reverse a half-reaction, what happens to the sign of Eo. Zn  Zn2+ + 2e- Eoox = 0.76 V Zn2+ + 2e- Zn Eored = ? • Now consider data for Eocell = 0.63 V for the following reaction. Zn + Pb2+ Zn2+ + Pb • What is the Eored of Pb2+ + 2e- Pb ?

  15. Cell Potential Values • Zn  Zn2+ + 2e- Eoox = 0.76 V • Pb2+ + 2e- Pb Eored = ? • Zn + Pb2+ Zn2+ + Pb Eocell = 0.63 V • Eocell = Eored + Eoox • 0.63 V = Eored + 0.76 V • Eored = 0.63 V - 0.76 V = -0.13 V • Values determined in this way are listed in Table 17.1 and Appendix 5.5

  16. Reduction Potentials

  17. Relative Strengths of Oxidizing and Reducing Agents

  18. Cell Potential • Reduction or oxidation values can also be measured from Eocell with other known half-cells. • AgCl + e- Ag + Cl- Eredo = 0.22 V • Hg2Cl2 + 2e- 2Hg + 2Cl- Eredo = 0.2802 V • Half-cells such as these are used as reference electrodes. The Ag/AgCl electrode, along with a glass electrode, is used in a pH meter.

  19. 17.2 Describing Galvanic Cells • What will happen if we place a piece of Zn and a piece of Cu in a solution that contains a mixture of Zn2+ and Cu2+? • Two possibilities: • Zn + Cu2+ Zn2+ + Cu • Cu + Zn2+ Cu2+ + Zn

  20. Spontaneous Redox • Two possible reduction half-reactions: • Zn2+ + 2e- Zn Eored = -0.76 V • Cu2+ + 2e- Cu Eored = 0.34 V • Two possible oxidation half-reactions: • Zn  Zn2+ + 2e- Eoox = 0.76 V • Cu  Cu2+ + 2e- Eoox = -0.34 V • One way to combine them: Zn2+ + 2e- Zn Eored = -0.76 V Cu  Cu2+ + 2e- Eoox = -0.34 V ———————— ———————— Cu + Zn2+ Cu2+ + Zn Eorxn = -1.10 V

  21. Spontaneous Redox • Other way to combine them: Cu2+ + 2e- Cu Eored = 0.34 V Zn  Zn2+ + 2e- Eoox = 0.76 V ———————— ——————— Zn + Cu2+ Zn2+ + Cu Eorxn = 1.10 V • Which combination is observed to be spontaneous. skip

  22. Stability in Aqueous Systems • Reaction with Water • Reduce hydronium ion to release hydrogen gas: • 2H+(aq) + 2e-H2(g) E°red = 0.000 V • Any substance with Eoox > 0 will reduce H+ to H2 • Examples are V, V2+, Cr, Cr2+, Mn • The ions will react, but tend to react only very slowly. There seems to be a kinetic factor that results in a fast reaction only if Eorxn > 0.4-0.5 V (called an overvoltage).

  23. Stability in Aqueous Systems • Reaction with Water • Oxidize water to release oxygen gas: • 2H2O(l) O2(g) + 4H+(aq) + 4e- E°ox = -1.23 V • Any Eored > 1.23 V will result in production of O2. Generally need Eorxn > 0.4-0.5 V for fast reaction. • Examples are Cr2O72- (very slow), MnO42- (disproportionates faster), Mn3+ (disproportionates faster)

  24. Stability in Aqueous Systems • Oxidation by O2 in Air • O2(g) + 4H+(aq) + 4e-2H2O(l) E°red = 1.23 V • Any Eoox > -1.23 V will result in oxidation by air. Many substances fall into this category (Eorxn > 0.4-0.5 V for fast reaction). • V Cr Mn • V2+ Cr2+ not Mn2+ • V3+ not Cr3+ Mn3+ • VO2+ (very slow) not MnO2 • MnO42- (disproportionates faster)

  25. Eocell and Spontaneity • We have seen three criteria for spontaneity: • Eo > 0 • DGo < 0 1 V = 1 J/C, so 1 J = 1 C x 1 V • These criteria are related: • K >> 1 • DGo = - RT lnK • DGo = - n F Eo, DG = - nFE where n = number of e- transferred and F = Faraday constant (charge on 1 mole e-) 1 F = 96,500 coul/mol e- = 96,500 J/V mol e-

  26. Thermodynamics • These relationships work for half-reactions or complete redox reactions. • Zn + Cu2+ Zn2+ + Cu Eo = 1.10 n = 2 • DGo = -2mol e- x 96500 J/V mol e- x 1.10 V • DGo = -212,300 J = -212.3 kJ • DGo depends on the number of moles, but Eo does not

  27. Voltage and Moles • Note that different size alkaline cells all deliver the same voltage, in spite of different number of moles of reactants.

  28. Thermodynamics • We can add Eoox to Eored to give Eocell or Eorxn in the same way that we can add half-reactions to give an overall reaction. • Fe  Fe2+ + 2e- Eoox = +0.44 V DGoox = - 2 x 96500 x 0.44 = -84900 J • Cl2 + 2e- 2Cl- Eored = 1.36 V DGored = - 2 x 96500 x 1.36 = -262500 J • Fe + Cl2 Fe2+ + 2Cl- Eorxn = 1.80 V DGo = - 2 x 96500 x 1.80 = -347400 J • DGorxn = DGoox + DGored = -84900 + -262500 = -347400 J

  29. Thermodynamics • From Chapter 16, we know that DGo values are additive when we add reactions. • Eos are additive when we add half-reactions to give a complete reaction because the value of n is the same for the half-reactions and the complete reaction. • Eos are not additive when adding two half-reactions to give a third half-reaction because the value of n is not constant.

  30. Thermodynamics • We can add DGo under all circumstances: DGo3 = DGo1 + DGo2 -n3FEo3 = -n1FEo1 - n2FEo2 n3Eo3 = n1Eo1 + n2Eo2 Eo3 = (n1Eo1 + n2Eo2)/n3 • V  V2+ + 2e- Eo1 = 1.20 V V2+V3+ + e- Eo2 = 0.26 V V V3+ + 3e- Eo3 < 1.20 + 0.26 • Eo3 = (2 x 1.20 + 1 x 0.26)/3 = 0.887 V

  31. Thermodynamics • We can calculate Keq from Eo: • DGo = - nFEo = - RT ln K • Eo = (RT/nF) ln K = 2.303 (RT/nF) log K • At 25oC, 2.303 RT/F = 0.05916 • Eo = (0.05916/n) log K at 25oC • Thus, we can measure Eo for a redox reaction and then calculate the equilibrium constant for that reaction.

  32. 17.4 Effect of Concentration on Cell EMF • So far, we have been using standard state conditions, but we don’t always have 1 M solutions. We can correct Eo to E by using the Nernst equation. • DG = DGo + RT ln Q • But, DG = - nFE and DGo = -nFEo, so • - nFE = -nFEo + 2.303 RT log Q • E = Eo - (2.303 RT/nF) log Q • At 25oC, E = Eo - (0.05916/n) log Q

  33. Nernst Equation • At 25oC, E = Eo - (0.05916/n) log Q • E = Eo if Q = 1 • When the system reaches equilibrium, Q = K, and E = 0, because Eo = (0.05916/n) log K, and the cell has “run down”. • Consider the Zn/Cu2+ reaction if more Cu2+ is added to the cell. The voltage becomes greater than 1.10 V. 21m07an1

  34. Nernst Equation • What is E of the Zn/Cu2+ reaction if [Cu2+] = 0.010 M and [Zn2+] =1.99 M? Note that this corresponds to starting with standard conditions and changing to 99% completion of reaction. Eo = 1.10 V (with [Cu2+] = [Zn2+] = 1.00 M) • Zn + Cu2+ Zn2+ + Cu • For this reaction, n = 2. • Q = [Zn2+]/[Cu2+]

  35. Nernst Equation • E = Eo - (0.05916/n) log Q • E = 1.10 V - (0.05916/2) log (1.99/0.010) • E = 1.10 V - (0.05916/2) log 199 • E = 1.10 - 0.068 = 1.03 V • For 99.9% reaction (1.999 M Zn2+, 0.001 M Cu2+), E = 1.10 - 0.098 = 1.00 V • For 99.99% reaction, 1.9999 M Zn2+, 0.0001 M Cu2+), E = 1.10 - 0.127 = 0.97 V

  36. Concentration Cells • We can generate a voltage with a cell that contains the same materials in the cathode and anode compartments, but at different concentrations.