1 / 1

High-Sensitivity Detector for Molecular Sensing using Magnetic Particles

High-Sensitivity Detector for Molecular Sensing using Magnetic Particles. S.-H. Liou, D. J. Sellmyer, R. Skomski, and R. Y. Lai ( Nebraska MRSEC).

manasa
Download Presentation

High-Sensitivity Detector for Molecular Sensing using Magnetic Particles

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High-Sensitivity Detector for Molecular Sensing using Magnetic Particles S.-H. Liou, D. J. Sellmyer, R. Skomski, and R. Y. Lai (Nebraska MRSEC) The detection of noxious gases or bio-agents is important for various environmental and security needs. High sensitivity, sufficient selectivity and molecular recognition are key characteristics for such sensing. Nebraska MRSEC researchers have developed a scheme for molecular sensing using magnetic tracer particles and a microcantilever torsional magnetometer. An example of using this system with a detection process is illustrated in the Figure. The feasibility of this technique is demonstrated with regard to successful chemical reactions and the magnetic moment sensitivity of about 7.2 x 10-11 emu, which corresponds to the magnetic moment of a single Fe particle of 400 nm is diameter. (Damien Le Roy et al., J. Appl. Phys., 109, 07E532, 2011). Detection principle using trinitrotoluene (TNT) molecules: (a) the functionalization of the cantilevers with TNT molecules (zero magnetization). (b) The TNT-analog molecules conjugated with magnetic tracer particles that occupy the TNT receptors (maximum magnetization), and (c) the exposure to TNT that triggers desorption of the magnetic particles from the cantilever surface. A steplike decrease of the magnetization proportional to the TNT concentration is then recorded. These programs are supported by the National Science Foundation, Division of Materials Research, Materials Research Science and Engineering Program, Grant 0820521.

More Related