Chromaticity decay during injection – symmetry between horizontal and vertical decay

CERN, FiDeL meeting, 14 th February 2012 . Chromaticity decay during injection – symmetry between horizontal and vertical decay. Nicholas Aquilina TE-MSC-MDT Acknowledgements: E. Todesco. Scope of the study.

manju
Download Presentation

Chromaticity decay during injection – symmetry between horizontal and vertical decay

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CERN, FiDeL meeting, 14thFebruary 2012 Chromaticity decay during injection – symmetry between horizontal and vertical decay Nicholas Aquilina TE-MSC-MDT Acknowledgements: E. Todesco

  2. Scope of the study • To check if the chromaticity decays by the same amount in the horizontal and vertical plane • Correction is applied through the spool pieces • one corrector to correct for both planes

  3. Data used • Beam measurements performed during weeks 18 to 25 (during 2011) equivalent to fills 1755 to 1898 (45 cases) • In these measurements the spool pieces had the same current for all ramps • Full correction was obtained by using the lattice sextuples

  4. Results • From the measured chromaticity, the lattice sextupoles corrections were removed • Correction from the spool pieces was not removed (as it was the same for all cases) • Effectiveness of the spool correction was observed • Behaviour of the bare machine is also known

  5. Examples (1) • Chromaticity behaviour is stable (therefore the spool correction was enough to correct for the decay). This implies that the decay behaviour was symmetric

  6. Examples (2) • Chromaticity decays by the same amount in both planes

  7. Examples (3) • Decay in the horizontal plane is about 1 unit more than that in the vertical plane 4 units 3 units

  8. Examples (4) • Difference of 2 units is observed between the horizontal and vertical plane

  9. Examples (5) • Difference of 2 unit is observed between the horizontal and vertical plane

  10. Examples (6) • Difference of 2 unit is observed between the horizontal and vertical plane 8 units 6 units

  11. Conclusions • Chromaticity decays by 22 units during injection, if left uncorrected • Maximum asymmetry of 2 units of chromaticity • This was observed in 18% of the cases analysed