An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ALICE RF SystemAndy Moss & Alan Wheelhouse,ASTeC, Daresbury Laboratory ALICE RF System Andy Moss/Alan Wheelhouse

  2. RF System • Main Menu • RF Operation • Switching on the IOTs • RF Control • Monitoring Systems • IOTs • Linac & Booster Cavities • Buncher Cavity • Pressure Monitoring ALICE RF System Andy Moss/Alan Wheelhouse

  3. Main Menu RF Drop Down Menu • RF Buncher • RF Booster 1 • RF Booster 2 • RF Linac 1 • RF Linac 2 • RF PSU • Linac Module • Booster Module • RF Buncher • Adhoc RF Gain • Tuner Motor Test ALICE RF System Andy Moss/Alan Wheelhouse

  4. RF Operation ALICE RF System Andy Moss/Alan Wheelhouse

  5. RF PSU Control • Analogue Monitoring • Control Area • IOT Monitoring Main Menu → RF → RF PSU ALICE RF System Andy Moss/Alan Wheelhouse

  6. Switching On The IOTs • Press (Hold down) • Aux ON • SB ON • Filaments need 10 minutes • Check ion current is <1µA • HV ON • HV will slowly rise to 27kV, ~600mA • Check ion current is <1µA • Allow 10 minutes for the quiescent currents to stabilise • Switch RF ON ALICE RF System Andy Moss/Alan Wheelhouse

  7. RF On • Trace seen on oscilloscope • RF raised on each IOT to provide the required gradient for each of the Linac and Booster cavities • Check ion current is <1µA • Ditto for the solid state amplifier on the Buncher cavity ALICE RF System Andy Moss/Alan Wheelhouse

  8. RF Control – Linac & Booster Cavities Main Menu → RF → RF Linac 1 • RF power adjusted using the gradient • RF phase adjustment (station phase) • All other controls are fixed ALICE RF System Andy Moss/Alan Wheelhouse

  9. RF Control – Buncher Cavity Main Menu → RF → RF Buncher • RF power adjusted using the gradient • RF phase (station phase) • All other controls are fixed ALICE RF System Andy Moss/Alan Wheelhouse

  10. Operation • Quench • RF should switch off • If not immediately switch off rf press HV ON • Trips • Re-apply • Constant trips seek assistance • IOT arc detector trips need to be reset at the PLC • An additional screen will be added in the future ALICE RF System Andy Moss/Alan Wheelhouse

  11. Monitoring Systems ALICE RF System Andy Moss/Alan Wheelhouse

  12. IOT Readings • All IOT limits are set within the PLC • Power measurements • Drive • Output • Additional voltage readings Main Menu → RF → RF PSU → LC IOT5 ALICE RF System Andy Moss/Alan Wheelhouse

  13. Booster & Linac Readings • Power Measurements • Waveguide power • Cavity probe power Main Menu → RF → RF PSU → Linac ALICE RF System Andy Moss/Alan Wheelhouse

  14. Buncher Readings Main Menu → RF → RF PSU → Buncher ALICE RF System Andy Moss/Alan Wheelhouse

  15. Calibration Readings • Calibration readings for all the power measurements • DO NOT TOUCH Main Menu → RF → Adhoc RF Gain ALICE RF System Andy Moss/Alan Wheelhouse

  16. SC Module Monitoring • Monitoring for Booster and Linac Cavities • Cavity power and gradient • Waveguide powers • Cavity pressure • Cold & warm window temperatures Main Menu → RF → Linac Module ALICE RF System Andy Moss/Alan Wheelhouse

  17. Machine Vacuum Monitoring Main Menu → Machine → Vacuum ALICE RF System Andy Moss/Alan Wheelhouse

  18. Injector Vacuum Monitoring Main Menu → Injector → Vacuum ALICE RF System Andy Moss/Alan Wheelhouse

  19. Monitoring Main Menu → General → Monitoring • Radiation monitoring • Pressure monitoring ALICE RF System Andy Moss/Alan Wheelhouse

  20. Monitoring - Graphs Main Menu → Injector → Injector Vacuum → Log Pressure 1hr ALICE RF System Andy Moss/Alan Wheelhouse