PRESENTATION iNELS. www.iNELS.com. CHARACTERISTICS. www.iNELS.com. iNELS ® i s a smart wiring system designed especially for :. switching dimming control and measurement monitored state of object integration of multimedia. installation bus CIB: communication and power supply units
E N D
PRESENTATION iNELS www.iNELS.com
CHARACTERISTICS www.iNELS.com • iNELS®is a smart wiring system designed especially for: • switching • dimming • controlandmeasurement • monitoredstateofobject • integrationof multimedia • installation bus CIB: communication and power supply units • actors (receivers) and sensors (transmitters) and data telegrams • IDM software-assigned functions and operating parameters PresentationiNELS
SYSTEM OPTIONS OF iNELS www.iNELS.com • switching and dimmingoflighting • Detection of indoor and outdoor movement and light intensity • motioncontrolblinds, shutters, awnings, garage, doors, entrancegatesetc. • management systems, heating and air conditioning • control various appliances (with interlocks on selected priorities) • integratedelectronicsecurity alarm • Remote Access (GSM and Internet) • visualization - IDM, iMM PresentationiNELS
THE POSSIBILITY APPLICATION OF iNELS www.iNELS.com • Houses (lighting, heating, air conditioning, ventilation, blinds, etc.) PresentationiNELS
THE POSSIBILITY APPLICATIONOF iNELS www.iNELS.com • Apartment buildings (plus common area management) PresentationiNELS
THE POSSIBILITY APPLICATION OF iNELS www.iNELS.com • Cottages (plus remoteaccess) PresentationiNELS
THE POSSIBILITY APPLICATION OF iNELS www.iNELS.com • Hotels and restaurants (the central feature scenes) PresentationiNELS
INSTALLATION BUS CIB www.iNELS.com • communication protocol is an internal (company) • response time of the entry into a central unit to output up to 150 ms • freetopology: • Linear Linear • Star • Tree • andtheircombinations Tree Star PresentationiNELS
PARAMETERS INSTALLATION BUS CIB www.iNELS.com • CU2-01M - 2 separate branches directly to CIB • - 4 more branches CIB via externalmasters • CP-1000- 2 separate branches directly to CIB • - 8 more branches CIB via externalmasters • total length of one branch (line) CIB maybe 550 m • on each branch 32 HW addresses, • is 32 units iNELS • 1A maximum load for each branch of the CIB PresentationiNELS
PARAMETERS INSTALLATION BUS CIB www.iNELS.com PresentationiNELS
SYSTEM BUS TCL2 www.iNELS.com • System with linear bus topology • Connecting external master module MI2-02M, which allowincreasing the number of branches (lines) installation bus CIB • Maximum lengthofTCL2 bus is 300 m • RecommendedcableJ-Y(St)-Y 2x2x0.8 • Ends with a resistancewithvalue120 Ω PresentationiNELS
SUMMARY - www.iNELS.com GENERAL PRINCIPLES FOR THE MANAGEMENT BUS • Accumulation of bus lines with power lead : • We recommend to avoid accumulation the power lead. Alternatively, a minimum distance from power lines 30 cm • Conditionsfor bus line : • Recommendedcables • Electromagnetic interference isavoided • Cable at any point is mechanically damaged • Cable must not be mechanically stressed (must be respected technologyinstallation procedures, temperature, bend radius, modes of attachment) PresentationiNELS
M E/G B DESIGN OF SYSTEM ELEMENTS www.iNELS.com DI/AC TI/AI • Modul „M“ - Installation on DIN rail DO AO DI/AC TI • Box „B“ - installation into a wiring box DO AO DI TI • Walldrivers DO PresentationiNELS
Central Unit CU2-01M www.iNELS.com 27.2 VDC CIB 1 CIB 2 TCL2 RS232 • Ethernet 10/100 Mbit/s • power 27.2V DC, 24V DC • 2x interfaces CIB • 1x interfaces TCL2 • 1x serialchanel RS-232 • 2x PSM Ethernet10/100base • 4x DI (IN1 - IN4) • 1x DO • integrated WEB server • SW IDM, SCADA/HMI Reliance, • OPC server PSM 4x DI 1x DO PresentationiNELS
External Master CIB MI2-02M www.iNELS.com TCL2 • 2 branchof CIB bus more • (identifying, addressing and configurationof units), data processing and transfer them toCU2-01M Circle switch • 1x TCL2 LED diod • Circle switch is used for setting the addressof MI2-02M on theTCL2bus CIB • LEDs for identificationcommunication on the CIBbus CIB PresentationiNELS
GSM Gate - GSM2-01 www.iNELS.com 27.2 VDC RS232 • 32 phonesnumbers • 48 outgoing SMSeach on a 20-digit • 32 incoming SMS eachon a 20-digit RMSA • defined dialing phone numbers and • ringing for 20 sec and end • You can defineactionson incoming calls PresentationiNELS
Bus separator for power supply BPS2-02M www.iNELS.com 27.2 VDC 2x CIB • ensures the correct power of two branches (lines) CIB, separates power supply unitsfrom peripheral and communicationmaster • terminals for connection27.2VDC source AKU terminals for connecting back-up battery • terminals +27 V and GND for powersupply and CU2-01-01 GSM2 27.2 VDC AKU • 2x CIB interfaces PresentationiNELS
Connectionsof BPS2-02M A CU2-02M www.iNELS.com PresentationiNELS
Connectionsof BPS2-02M A MI2-02M www.iNELS.com PresentationiNELS
Binary input - IM2-20B, IM2-40B, IM2-80B, IM2-140M www.iNELS.com 12 VDC 1x TI CIB 12 VDC 14x DI CIB 12 VDC 1x TI CIB 12 VDC 1x TI CIB 8x DI 2x DI 4x DI • 2x, 4x, 8x a 14x DI balancingoptionfor alarm 14x DI • contact inputs can be defined as NC / NO • output 12V DC / 75 mA (150 mA) forpowerof alarm units PresentationiNELS
Temperature input - TI2-40B, Analog input ADC2-40M www.iNELS.com CIB CIB 1x AI CIB 4x TI • 4x AI thecommonterminal GND • input - U, I a RTD • selectableranges • A / D converterresolution 14 bit • For poweringpassiveresistive sensor terminal with a reference voltage 5.4V 4x TI 3x AI • 4x TI - connectionresistancetemperaturesensorsTC/TZ • only in version IDM 1.1.3.576 PresentationiNELS
Dimmingactuator - LM2-11B www.iNELS.com CIB 1x TI CIB • switching and dimming load RLC • autodetectionofload • 1x TI • 1x a 2x DI (230V AC) • 1x a 2x AO (250 VA) 1x DI 1x AO PresentationiNELS
Dimmingactuator - DA2-22M www.iNELS.com • switching and dimming loadRLC, LED, (ESL) CIB CIB 1x TI • 1x TI • 1x a 2x DI (230V AC) • 1x a 2x AO (500 VA) Setuploadand minimum brightnesswith potentiometers on the frontside. • potential at terminal L on DA2-22M is recommended to protect the safety elementcorresponding to the connectedload (fuse characterized. F) 2x DI 2x AO PresentationiNELS
Dimmingactuator - DIM-6 www.iNELS.com CIB 1x AI 10 kW • switching and dimming load RLC • hw setupofload (jumper) • 1x AO (2000 VA) • 1x AI (0-10 V, 1-10 V) • modularexpandableup to 10 000 VA 1x DI 1x AO PresentationiNELS
Dimmingactuator - LBC2-02M www.iNELS.com CIB CIB 1x DO • control dimmable ballasts for fluorescent tube • 2x AO (1-10 V) • 2x DO (RO) (16 A/4000 VA AC1) 2x AO 1x DO PresentationiNELS
Switchingactuator - SA2-01B, SA2-02B www.iNELS.com CIB CIB 1x TI CIB CIB 1x TI • switchingappliancesandloads • 2x DO (RO) - floatingswitchingcontact • Relaycontact16 A/4000 VA AC1 - SA2-01B, 8 A/2000 VA AC1 - SA2-02B 1x DO 1x DO 1x DO PresentationiNELS
Shuttersactuator - JA2-02B , JA2-02/DC www.iNELS.com • motioncontrolshutters, blindsetc. CIB 1x TI CIB 1x TI • JA2-02B - 2x RO • 4 A/1000 VA AC3 • JA2-02B/DC - 2x RO - drives with supply voltage of 24V DC, direction of rotation is controlled bychanging the polarity of the motor UP L DOWN ◄ ◄ U PresentationiNELS
Switchingactuator - SA2-02M, SA2-04M www.iNELS.com CIB CIB CIB CIB 1x DO • switchingappliancesandloads • 2x DO (RO) - SA2-02M - floatingswitchingcontact 16 A/4000 VA AC1 • 4x DO (RO) - SA2-04M – floatingswitchingcontact 16 A/4000 VA AC1 1x DO 1x DO 1x DO 1x DO 1x DO PresentationiNELS
Switchingactuator - SA2-012M www.iNELS.com CIB 230 V AC 4x DO • switchingappliances and loads • 12x DO (RO) – switchingcontact • 8 A/2000 VA AC1 • each of four identicaloutputs switching thesamepotential • powerfor unit is 230V AC 4x DO 4x DO PresentationiNELS
Analog output - DAC2-04B, DAC2-04M www.iNELS.com CIB CIB CIB CIB 1x TI • 4x AO - 0-10V, 1-10V • control devices that are controlled by this signal(dimmable ballasts of fluorescent lamps,dimmers, thermoelectricvalves, servodrives, instrumentationelement) 4x AO 4x AO PresentationiNELS
Thermovalvecontroler - HC2-01B/AC, HC2-01B/DC www.iNELS.com • switchingthermoelectricheads 0/1 CIB • CIB • 1x TI CIB CIB 1x TI • HC2-01B/AC – 1x DO - 24 - 230V AC Maximum peakcurrent0.15 A/230V AC • HC2-01B/DC – 1x DO - 24V DC • Maximum peakcurrent0.5 A/30V DC • 1x AO - 0-10V 1x DO • 1x AO 1x DO PresentationiNELS
Multifunctioncontrol unit - SOPHY2, SOPHY2-L www.iNELS.com • sensor of the human voice • ambientlight intensity sensor 1x DI 4x DI • 1x TI - integratedtemperature sensor • IR receiver • IR transmitter • 6x DI CIB 1x DI • design in a LOGUS90 PresentationiNELS
Wall Switch - WSB2-20, WSB2-40, WSB2-80 www.iNELS.com • integrated micro-switches with a low stroke • design: • WSB2-20 - 2x DI, 2x DO CIB CIB • WSB2-40 - 4x DI, 4x DO • WSB2-80 - 8x DI, 8x DO • 1x TI - integratedtemperature sensor • design in a LOGUS90 PresentationiNELS
Termoregulator - IDRT2-01 www.iNELS.com • control temperature and heating circuit • 1x TI Mode • 1x AI - correction in therange+/- 3°C • 2x DO indicate LED • design in Logus90 State Korekce PresentationiNELS
Touchscreen - EST2, EST2/RGB www.iNELS.com • 3,5“ touchscreen • It consists of 3 (4) iNELS elements : IM2-140M, IDRT2, KEY2-01, (ADC2-40M) • 2(3) mainscreen: Withconfigurableicons,withdigitalcontrollerfortemperaturecorection, (screenfor RGB control) • design in a LOGUS90 PresentationiNELS
EST2 configurableicons www.iNELS.com • Option 4-12 icons • 48 differenticons in librery • Distinguishes between long and short press configuration is setup via binary inputs IM2-140M • Design in a LOGUS90 PresentationiNELS
EST2 termostat a RGB control www.iNELS.com PresentationiNELS
EST2 connectionforcontrol RGB www.iNELS.com PresentationiNELS
www.iNELS.com THANK YOUFOR YOURATTENTION Martin Ševela Product manager P a l a c k e h o 4 9 3 | 7 6 9 0 1 Ho l e s o v, V s e t u l y | Cz e c h R e p u b l i c t e l . : + 4 2 0 5 7 3 5 1 4 2 2 1 | f a x : + 4 2 0 5 7 3 5 1 4 2 2 7 | e l k o@e l k o e p . c om | www. e l k o e p . c om PresentationiNELS