1 / 39

www.iNELS.com

PRESENTATION iNELS. www.iNELS.com. CHARACTERISTICS. www.iNELS.com. iNELS ® i s a smart wiring system designed especially for :. switching dimming control and measurement monitored state of object integration of  multimedia. installation bus CIB: communication and power supply units

marcy
Download Presentation

www.iNELS.com

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PRESENTATION iNELS www.iNELS.com

  2. CHARACTERISTICS www.iNELS.com • iNELS®is a smart wiring system designed especially for: • switching • dimming • controlandmeasurement • monitoredstateofobject • integrationof multimedia • installation bus CIB: communication and power supply units • actors (receivers) and sensors (transmitters) and data telegrams • IDM software-assigned functions and operating parameters PresentationiNELS

  3. SYSTEM OPTIONS OF iNELS www.iNELS.com • switching and dimmingoflighting • Detection of indoor and outdoor movement and light intensity • motioncontrolblinds, shutters, awnings, garage, doors, entrancegatesetc. • management systems, heating and air conditioning • control various appliances (with interlocks on selected priorities) • integratedelectronicsecurity alarm • Remote Access (GSM and Internet) • visualization - IDM, iMM PresentationiNELS

  4. THE POSSIBILITY APPLICATION OF iNELS www.iNELS.com • Houses (lighting, heating, air conditioning, ventilation, blinds, etc.) PresentationiNELS

  5. THE POSSIBILITY APPLICATIONOF iNELS www.iNELS.com • Apartment buildings (plus common area management) PresentationiNELS

  6. THE POSSIBILITY APPLICATION OF iNELS www.iNELS.com • Cottages  (plus remoteaccess) PresentationiNELS

  7. THE POSSIBILITY APPLICATION OF iNELS www.iNELS.com • Hotels and restaurants (the central feature scenes) PresentationiNELS

  8. INSTALLATION BUS CIB www.iNELS.com • communication protocol is an internal (company) • response time of the entry into a central unit to output up to 150 ms • freetopology: • Linear Linear • Star • Tree • andtheircombinations Tree Star PresentationiNELS

  9. PARAMETERS INSTALLATION BUS CIB www.iNELS.com • CU2-01M - 2 separate branches directly to CIB • - 4 more branches CIB via externalmasters • CP-1000- 2 separate branches directly to CIB • - 8 more branches CIB via externalmasters • total length of one branch (line) CIB maybe 550 m • on each branch 32 HW addresses, • is 32 units iNELS • 1A maximum load for each branch of the CIB PresentationiNELS

  10. PARAMETERS INSTALLATION BUS CIB www.iNELS.com PresentationiNELS

  11. SYSTEM BUS TCL2 www.iNELS.com • System with linear bus topology • Connecting external master module MI2-02M, which allowincreasing the number of branches (lines) installation bus CIB • Maximum lengthofTCL2 bus is 300 m • RecommendedcableJ-Y(St)-Y 2x2x0.8 • Ends with a resistancewithvalue120 Ω PresentationiNELS

  12. SUMMARY -  www.iNELS.com GENERAL PRINCIPLES FOR THE MANAGEMENT BUS • Accumulation of bus lines with power lead : • We recommend to avoid accumulation the power lead. Alternatively, a minimum distance from power lines 30 cm • Conditionsfor bus line : • Recommendedcables • Electromagnetic interference isavoided • Cable at any point is mechanically damaged • Cable must not be mechanically stressed (must be respected technologyinstallation procedures, temperature, bend radius, modes of attachment) PresentationiNELS

  13. M E/G B DESIGN OF SYSTEM ELEMENTS www.iNELS.com DI/AC TI/AI • Modul „M“ - Installation on DIN rail DO AO DI/AC TI • Box „B“ - installation into a wiring box DO AO DI TI • Walldrivers DO PresentationiNELS

  14. Central Unit CU2-01M www.iNELS.com 27.2 VDC CIB 1 CIB 2 TCL2 RS232 • Ethernet 10/100 Mbit/s • power 27.2V DC, 24V DC • 2x interfaces CIB • 1x interfaces TCL2 • 1x serialchanel RS-232 • 2x PSM Ethernet10/100base • 4x DI (IN1 - IN4) • 1x DO • integrated WEB server • SW IDM, SCADA/HMI Reliance, • OPC server PSM 4x DI 1x DO PresentationiNELS

  15. External Master CIB MI2-02M www.iNELS.com TCL2 • 2 branchof CIB bus more • (identifying, addressing and configurationof units), data processing and transfer them toCU2-01M Circle switch • 1x TCL2 LED diod • Circle switch is used for setting the addressof MI2-02M on theTCL2bus  CIB • LEDs for identificationcommunication on the CIBbus  CIB PresentationiNELS

  16. GSM Gate - GSM2-01 www.iNELS.com 27.2 VDC RS232 • 32 phonesnumbers • 48 outgoing SMSeach on a 20-digit • 32 incoming SMS eachon a 20-digit RMSA • defined dialing phone numbers and • ringing for 20 sec and end • You can defineactionson incoming calls PresentationiNELS

  17. Bus separator for power supply BPS2-02M www.iNELS.com 27.2 VDC 2x CIB • ensures the correct power of two branches (lines) CIB, separates power supply unitsfrom peripheral and communicationmaster • terminals for connection27.2VDC source AKU terminals for connecting back-up battery • terminals +27 V and GND for powersupply and CU2-01-01 GSM2 27.2 VDC AKU • 2x CIB interfaces PresentationiNELS

  18. Connectionsof BPS2-02M A CU2-02M www.iNELS.com PresentationiNELS

  19. Connectionsof BPS2-02M A MI2-02M www.iNELS.com PresentationiNELS

  20. Binary input - IM2-20B, IM2-40B, IM2-80B, IM2-140M www.iNELS.com 12 VDC 1x TI CIB 12 VDC 14x DI CIB 12 VDC 1x TI CIB 12 VDC 1x TI CIB 8x DI 2x DI 4x DI • 2x, 4x, 8x a 14x DI balancingoptionfor alarm 14x DI • contact inputs can be defined as NC / NO • output 12V DC / 75 mA (150 mA) forpowerof alarm units PresentationiNELS

  21. Temperature input - TI2-40B, Analog input ADC2-40M www.iNELS.com CIB CIB 1x AI CIB 4x TI • 4x AI thecommonterminal GND • input - U, I a RTD • selectableranges • A / D converterresolution 14 bit • For poweringpassiveresistive sensor terminal with a reference voltage 5.4V 4x TI 3x AI • 4x TI - connectionresistancetemperaturesensorsTC/TZ • only in version IDM 1.1.3.576 PresentationiNELS

  22. Dimmingactuator - LM2-11B www.iNELS.com CIB 1x TI CIB • switching and dimming load RLC • autodetectionofload • 1x TI • 1x a 2x DI (230V AC) • 1x a 2x AO (250 VA) 1x DI 1x AO PresentationiNELS

  23. Dimmingactuator - DA2-22M www.iNELS.com • switching and dimming loadRLC, LED, (ESL) CIB CIB 1x TI • 1x TI • 1x a 2x DI (230V AC) • 1x a 2x AO (500 VA) Setuploadand minimum brightnesswith potentiometers on the frontside. • potential at terminal L on DA2-22M is recommended to protect the safety elementcorresponding to the connectedload  (fuse characterized. F) 2x DI 2x AO PresentationiNELS

  24. Dimmingactuator - DIM-6 www.iNELS.com CIB 1x AI 10 kW • switching and dimming load RLC • hw setupofload (jumper) • 1x AO (2000 VA) • 1x AI (0-10 V, 1-10 V) • modularexpandableup to 10 000 VA 1x DI 1x AO PresentationiNELS

  25. Dimmingactuator - LBC2-02M www.iNELS.com CIB CIB 1x DO • control dimmable ballasts for fluorescent tube • 2x AO (1-10 V) • 2x DO (RO) (16 A/4000 VA AC1) 2x AO 1x DO PresentationiNELS

  26. Switchingactuator - SA2-01B, SA2-02B www.iNELS.com CIB CIB 1x TI CIB CIB 1x TI • switchingappliancesandloads • 2x DO (RO) - floatingswitchingcontact • Relaycontact16 A/4000 VA AC1 - SA2-01B, 8 A/2000 VA AC1 - SA2-02B 1x DO 1x DO 1x DO PresentationiNELS

  27. Shuttersactuator - JA2-02B , JA2-02/DC www.iNELS.com • motioncontrolshutters, blindsetc. CIB 1x TI CIB 1x TI • JA2-02B - 2x RO • 4 A/1000 VA AC3 • JA2-02B/DC - 2x RO - drives with supply voltage of 24V DC, direction of rotation is controlled bychanging the polarity of the motor UP L DOWN ◄ ◄ U PresentationiNELS

  28. Switchingactuator - SA2-02M, SA2-04M www.iNELS.com CIB CIB CIB CIB 1x DO • switchingappliancesandloads • 2x DO (RO) - SA2-02M - floatingswitchingcontact 16 A/4000 VA AC1 • 4x DO (RO) - SA2-04M – floatingswitchingcontact 16 A/4000 VA AC1 1x DO 1x DO 1x DO 1x DO 1x DO PresentationiNELS

  29. Switchingactuator - SA2-012M www.iNELS.com CIB 230 V AC 4x DO • switchingappliances and loads • 12x DO (RO) – switchingcontact • 8 A/2000 VA AC1 • each of four identicaloutputs switching thesamepotential • powerfor unit is 230V AC 4x DO 4x DO PresentationiNELS

  30. Analog output - DAC2-04B, DAC2-04M www.iNELS.com CIB CIB CIB CIB 1x TI • 4x AO - 0-10V, 1-10V • control devices that are controlled by this signal(dimmable ballasts of fluorescent lamps,dimmers, thermoelectricvalves, servodrives, instrumentationelement) 4x AO 4x AO PresentationiNELS

  31. Thermovalvecontroler - HC2-01B/AC, HC2-01B/DC www.iNELS.com • switchingthermoelectricheads 0/1 CIB • CIB • 1x TI CIB CIB 1x TI • HC2-01B/AC – 1x DO - 24 - 230V AC Maximum peakcurrent0.15 A/230V AC • HC2-01B/DC – 1x DO - 24V DC • Maximum peakcurrent0.5 A/30V DC • 1x AO - 0-10V 1x DO • 1x AO 1x DO PresentationiNELS

  32. Multifunctioncontrol unit - SOPHY2, SOPHY2-L www.iNELS.com • sensor of the human voice • ambientlight intensity sensor 1x DI 4x DI • 1x TI - integratedtemperature sensor • IR receiver • IR transmitter • 6x DI CIB 1x DI • design in a LOGUS90 PresentationiNELS

  33. Wall Switch - WSB2-20, WSB2-40, WSB2-80 www.iNELS.com • integrated micro-switches with a low stroke • design: • WSB2-20 - 2x DI, 2x DO CIB CIB • WSB2-40 - 4x DI, 4x DO • WSB2-80 - 8x DI, 8x DO • 1x TI - integratedtemperature sensor • design in a LOGUS90 PresentationiNELS

  34. Termoregulator - IDRT2-01 www.iNELS.com • control temperature and heating circuit • 1x TI Mode • 1x AI - correction in therange+/- 3°C • 2x DO indicate LED • design in Logus90 State Korekce PresentationiNELS

  35. Touchscreen - EST2, EST2/RGB www.iNELS.com • 3,5“ touchscreen • It consists of 3 (4) iNELS elements : IM2-140M, IDRT2, KEY2-01, (ADC2-40M) • 2(3) mainscreen: Withconfigurableicons,withdigitalcontrollerfortemperaturecorection, (screenfor RGB control) • design in a LOGUS90 PresentationiNELS

  36. EST2 configurableicons www.iNELS.com • Option 4-12 icons • 48 differenticons in librery • Distinguishes between long and short press configuration is setup via binary inputs IM2-140M • Design in a LOGUS90 PresentationiNELS

  37. EST2 termostat a RGB control www.iNELS.com PresentationiNELS

  38. EST2 connectionforcontrol RGB www.iNELS.com PresentationiNELS

  39. www.iNELS.com THANK YOUFOR YOURATTENTION Martin Ševela Product manager P a l a c k e h o 4 9 3 | 7 6 9 0 1 Ho l e s o v, V s e t u l y | Cz e c h R e p u b l i c t e l . : + 4 2 0 5 7 3 5 1 4 2 2 1 | f a x : + 4 2 0 5 7 3 5 1 4 2 2 7 | e l k o@e l k o e p . c om | www. e l k o e p . c om PresentationiNELS

More Related