1 / 13

2D-S Participation in RACORO

2D-S Participation in RACORO. Brad Baker, Paul Lawson and Qixu Mo. Outline . 2D-S Features Examples of Quicklook IOPshare 2D-S Products Data Place in Final Archives.

maren
Download Presentation

2D-S Participation in RACORO

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2D-S Participation in RACORO Brad Baker, Paul Lawson and Qixu Mo

  2. Outline • 2D-S Features • Examples of Quicklook IOPshare 2D-S Products • Data Place in Final Archives.

  3. Custom 128-photodiode array/front end with ~ 10 times the response speed of older probes (smaller 50 m pixels on the array). • 10 m particles imaged at 170 m s-1 (front end up to 233 m s-1) • Two independent imaging probes in one instrument provide stereo images of some particles and measurement redundancy • Large Sample Volume: 3 times the 2D-C Sample Volume

  4. Example Showing how 2D-S Particle Inter-arrival Times are used to Remove Shattered (and Splashed) Images

  5. Example of Correcting out-of-focus “Donuts”

  6. Some Examples of ARM Quicklook IOPshare 2D-S Products • Comparison of 2D-S, CAS and CIP PSD’s • Time Series and Scatterplot Comparisons of 2D-S H and V channels • Time Series and Scatterplot Comparisons of 2D-S from 10 to 50 m with CAS from 9 to 50 m • Time Series and Scatterplot Comparisons of 2D-S > 50 m with CIP > 50 m.

  7. Comparison ofPSD’s: CAS,CIP, 2D-S (V) , 2D-S (H)

  8. Time Series Comparison:CAS 9 to 50 m 2D-S (V) 10 to 50 m 2D-S (H) 10 to 50 m

  9. Comparison of 2D-S (V) and 2D-S (H) Channels

  10. Scatterplot Comparison: 2D-S (V) 10 to 50 m CAS 9 to 50 m

  11. Time Series Comparison:CIP > 50 m 2D-S (V) > 50 m 2D-S (H) > 50 m

  12. Scatterplot Comparison: 2D-S (V) > 50 m CIP > 50 m

  13. 2D-S Archive Data • 1-Hz PSD’s of Concentration, Area and Mass with Splashers Removed and “Donuts” Resized • 1-Hz Total Particle Concentration, Extinction, LWC, Effective Radius, Radar Reflectivity • 2D-S Images: All Images Archived.