1 / 69

NOTIFIER ® Fire Alarm & Emergency Communication

NOTIFIER ® Fire Alarm & Emergency Communication. A World of Solutions. Delivering Innovative Life Safety Products for over 50 years Global Presence, Local Knowledge Over 400 independent global business partners (ESDs) Fully backed by NOTIFIER. Leaders in Life. Safety. Technology.

maren
Download Presentation

NOTIFIER ® Fire Alarm & Emergency Communication

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NOTIFIER® Fire Alarm&Emergency Communication

  2. A World of Solutions • Delivering Innovative Life Safety Products for over 50 years • Global Presence, Local Knowledge • Over 400 independent global business partners (ESDs) • Fully backed by NOTIFIER Leaders in Life. Safety. Technology

  3. ONYX® Series Comprehensive Line of Life Safety Control Panels And Peripheral Devices

  4. NFS-320 • Single SLC Loop Addressable Life Safety System • Maximum 159 addressable detectors & 159 addressable modules • Standalone panel or networkable via Noti-Fire-Net • Standard and Advanced Detection Capabilities • Multiple Off-Premise Communication Options • Multiple Integration Options • Typical Applications Typical Applications: • K-12 Schools • Standalone Retail • Small Commercial • Strip Malls • Restaurants

  5. NFS2-640 • Single or Dual SLC Loop Addressable Life Safety System • Maximum 318 addressable detectors & 318 addressable modules • Standalone system or networkable via Noti-Fire-Net • Standard and Advanced Detection Capabilities • Integrated Digital Voice Option • Multiple Off-Premise Communication Options • Multiple Integration Options • Typical Applications Typical Applications: • Commercial Offices • Educational Buildings • Assisted Living Facilities • Strip Malls • Hotels

  6. NFS2-3030 • Multiple Loop Addressable Life Safety System • Up to 10 SLC loops • 1,590 addressable detectors & 1,590 addressable modules • Standalone panel or networkable via Noti-Fire-Net • Standard & Advanced Detection Capabilities • Integrated Digital Voice Option • Listed for releasing applications • Optional addressable 4-20 mA analog input module • Multiple Off-Premise Communication Options • Multiple Integration Options Typical Applications: • High Rise Buildings • College/University Campus • Hospitals • Airports • Hotels • Shopping Malls • Sports Arenas • Manufacturing Facilities

  7. ONYX® Series Features

  8. Detectors Acclimate® Plus Smoke / heat detector IntelliQuad™ 4-sensor fire detector IntelliQuad™ PLUS Combination fire & Carbon Monoxide detector VIEW ® (Laser) Detector Intelligent FAAST Aspiration Ionization Detector Heat Detectors Duct Detector Beam Detectors Photoelectric Series Modules Pull Station Control Module Releasing Module Dual Monitor Module Dual Input/Dual Relay Module Class A/B Input Module Class B Mini-Module 4-20 mA analog input Module NFS2-3030 only Relay Module Two-wire Smoke Detector Module Isolator Module ONYX® Series Addressable Devices Comprehensive Line of Addressable Smoke, Gas, Heat and Integration Devices

  9. ONYX® Series Backwards Compatibility • Existing legacy devices compatible with the ONYX Series • Makes upgrades and retrofits more cost effective and less time consuming • Minimal Interruption to normal facility operation • Reuse FACP enclosure

  10. ONYX® Series Gateway Options

  11. LEDSIGN Gateway (LEDSIGN-GW) • Ethernet IP Gateway for connection to Inova Solutions LED signs • Detailed event messages to applicable signs, alert messages to other signs

  12. VESDA HLI Gateway • Communication link between Noti-Fire-Net and VESDAnet • Monitor and control up to 100 detectors • Enables event notification and control of devices on the VESDAnet through the NFN network Up to 100 Devices High Level Gateway Protocol Translator NCM Embedded Gateway (Optional) VESADANet NOTI-FIRE-NET WORK STATION (Optional)

  13. NOTIFIER Web Server Gateway (NWS-3) • Access FACP status remotely over the internet or intranet • Send automatic emails or text messages (up to 50) View History Remotely Email Profile Configurations

  14. BACnet Gateway (BACNET-GW-3) • Interface between an ONYX Series panel or NOTI•FIRE•NET and a network using the BACnet/IP communication protocol • Panel information available to BACnet /IP Client

  15. MODBUS Gateway (MODBUS-GW) • Provides a communication link between networks that use the Modbus/TCP communication protocol and Fire Alarm Control Panels (FACPs) resident on an NFN network

  16. Common Alerting Protocol Gateway (CAP-GW) • Translates event information to industry standard CAP messages for use with CAP-compliant systems

  17. ONYX® Intelligent Sensing and Advanced Detection

  18. ONYX Series Intelligent Sensing • A suite of advanced specialty detectors allowing system designers to provide life safety protection in standard and challenging environments • ACCLIMATE ® Plus • IntelliQuad™ • VIEW® • IntelliQuad™ PLUS • Intelligent FAAST (FSA-8000)

  19. Acclimate Plus ® Multi-Criteria Detector • Combination of photoelectric and thermal sensing increases immunity to false alarms • Internal microprocessor adjusts sensitivity based on the environment without human intervention or control panel programming • Photoelectric detector sensitivity to smoke increases with sensed rise in heat • Capable of a heat-only mode • Low-Temp Trouble indication (at 40 F) Typical Applications: • Sleeping rooms Pre-Alarm for smoke with General Alarm for heat

  20. Photoelectric smoke sensing (Particulate) Thermal heat sensing (Heat) CO sensing (CO) Advanced time & logic functions (Coordination) IntelliQuad™ Multi-Criteria Detector • Uses four sensing elements working together to address each element of a fire • The panel threshold can be chosen based on the environment – sensing element weighting varies by level Infra-red light sensing (Light from flame) Typical Applications: • Mechanical Rooms • Kitchens • Restrooms • Laundries

  21. VIEW ® (Very Intelligent Early Warning) • Ideal for critical applications where even a trace of undetected smoke is unacceptable • System Features • Laser light source and patented optical design • Sensitivity that is 10 to 50 times higher than photoelectric technology • Benefits • Very early warning • Individual point annunciation Typical Applications: • Server Rooms • Electrical Equipment Rooms

  22. IntelliQuad™ PLUS Photoelectric / CO Detector • Uses four sensing elements working together to address each element of a fire: Photo, CO, Thermal and IR • The carbon monoxide sensor provides a separate CO signal to the panel • Can be configured with an intelligent sounder base to produce distinct audible alerts • Temp-3 for fire • Temp-4 for CO • Ideal for applications that require both smoke and CO detection Typical Applications: • Residential • Hospitality • Dormitories With B200S Sounder Base

  23. Intelligent FAAST (FSA-8000) Addressable Aspiration • Connects directly to NOTIFIER ONYX series addressable fire alarm control panels via the Signaling Line Circuit (SLC loop) • No interface cards or monitor modules required • Reduced equipment costs and installation time • Real-time information of early warning smoke and fire conditions transmitted to fire alarm control panel • Addressable spot smoke detection and aspiration in a single panel! SPOT PULL STATION • Sits on SLC with other standard devices PANELS FSA-8000 SPOT PULL STATION

  24. Intelligent FAAST – Common Applications

  25. Gas & Flame Detection Honeywell Analytics Gas Detection Broad range of Gas & Flame detection options to meet the needs of any commercial or industrial application Fire Sentry Flame Detection Combine Gas and Flame Protection with your ONYX Series Life Safety System for a total solution; eliminate the need for separate systems

  26. ONYX Series Gas Detection • ONYX Series (NFS-320/NFS2-640/NFS2-3030) • UL ‘Non-Monitor’ Listed for Gas Detection • Monitor normally-open contact type devices • NFS2-3030 • FM6320 Approved Gas Detection System with FMM-4-20 module • Can interface to any industry-standard, 4-20 mA protocol sensor: Gas, Oxygen, Temperature etc…

  27. Emergency Communications Systems (ECS)

  28. What is ECSand Why Notifier?

  29. Emergency Communication Systems Any system that is organized for the primary purpose of supporting one and two-way communication of emergency messages between both individuals and groups. These systems are commonly designed to integrate messaging across a variety of technologies, forming aunifiedsystem intended to optimize communications during emergencies.

  30. ECS Becoming a Code Driven Requirement • NFPA 72, 2010 & 2013 Editions, Chapter 24 – Emergency Communications Systems • UL2572, Mass Notification Systems • United Facilities Criteria (UFC) • IBC (2012) Educational (Group E) - schools and day care centers up to the 12th grade…

  31. IBC Group E – K-12 & Day Care “907.2.3 Group E. A manual fire alarm system that initiates the occupant notification signal utilizing an emergency voice / alarm communication system meeting the requirements of Section 907.5.2.2 and installed in accordance with Section 907.6 shall be installed in Group E occupancies. When automatic sprinkler systems or smoke detectors are installed, such systems or detectors shall be connected to the building fire alarm system.”

  32. Addressing The Risk • Many facilities are focusing on physical security – “hardening” their buildings • Access control • Bulletproof glass • Video surveillance • Security guards • This is good – but it is not enough

  33. ECS Goes Above and Beyond • Adding ECS ensures the ability to communicate before, during and after emergencies • ECS from NOTIFIER provides the same level of integrity, survivability and supervision our customers have come to expect from their fire alarm system

  34. NOTIFIER ECS: Digital Voice Command (DVC) • Integrate with single FACP or part of Noti-Fire-Net • 8 channel digital audio • Supports Firefighters Telephone • Local or Remote Paging • Analog Audio Option • Voice over IP Option • Integration with Third Party Systems: LED signage and Whelen “Giant Voice” outdoor speakers • Full line of indoor and outdoor speakers Typical Applications: • High Rise Buildings • College/University Campus • Hospitals • Airports • Hotels • Shopping Malls • Sports Arenas • Manufacturing Facilities

  35. NOTIFIER ECS: DVC • Up to 32 Digital Audio Amplifiers can be connected to a DVC center • Each Digital Audio Amplifier is configurable as a primary or backup amplifier • Larger applications can be accommodated with additional DVC centers • Each networked DVC adds support for another 32 Digital Audio Amplifiers • Applications requiring hundreds of audio zones can be created by networking DVC centers over NOTI•FIRE•NET™ • NOTI•FIRE•NET with DVC provides • Added survivability and scalability • Multiple command center support • System expansion

  36. NFN ONYX FACP DAA DAA NOTI•FIRE•NET with DVC • Backbone of a robust Emergency Communications Systems • Added survivability and scalability • Multiple command center support • Easily expandable

  37. DVC Third Party Integration • DVC audio can be integrated into Third Party systems, such as Whelen Giant Voice • Ability to activate the Whelen system with high level audio from a speaker circuit • Proprietary NOTIFIER ~ Whelen interface • No control modules required!

  38. DVC Third Party Integration • Third Party Audio, such as Whelen Giant Voice, can be easily integrated into the DVC

  39. NOTIFY-IP • NOTIFY-IP is a system of interconnected software and hardware that broadcasts live or prerecorded voice messages on DVCs • Requires ONYXWorks • NOTIFY-IP gives you: • Wide Area Capability • Country to Country • State to State • City to City • Large Campuses

  40. NOTIFIER ECS: NOTIFY-IP ONYXWorks TM with Notify IP DVC w/NCA-2 Attention… Attention… DAL (Digital Audio Loop) Noti-Fire-NetTM TCPIP Digital Series Amplifiers (up to 32) DAL (Digital Audio Loop) DVC (Digital Voice Command) with NFN Gateway

  41. FirstCommand Overview New emergency communications system (ECS) from NOTIFIER • Adds standalone or integrated emergency communications for voice evacuation • Direct integration and control with select NOTIFIER addressable panels • Works with any fire alarm control panel from any manufacturer • Expands NOTIFIER’s ECS capability to meet the needs of any size project Better serve small to medium size ECS applications

  42. FirstCommand-50/100 with NFS-320 Amber Strobe Threat/Evacuation buttons Speaker Circuit Strobe Circuit FCPS-24S6 Lighted Evacuation Sign

  43. NOTIFIER ECS: Digital Intelligent Signage • Supplements emergency voice messaging with visual signage • Fully integrated and supervised by ONYX panels and ONYXWorks • UL-listed LED signs and ONYX gateway • Intelligent signage allows for pre-programmed or customizable emergency messages – examples: • Security Breach Reported • Lock Down • All Clear • The Intelligent Signage allows for emergency messages to be displayed throughout a facility for company personnel or visitors Effective solution for the hearing impaired/high ambient noise areas

  44. LEDSIGN-GW: ONYX integration gateway • Up to10 LED signs per gateway • Each sign can display a unique message based on programming • Encrypted communications to the sign • Bright LEDs with wide viewing angle

  45. Distributed Messaging • Honeywell Instant Alert Plus • Standalone non-integrated solution Landline / Cellular Phones E-Mail SMS / Text Pager

  46. What is ECS and Why NOTIFIER? Fire Alarm & Emergency Communication Systems ONYXWorks TM NOTIFIER 3030 with Digital Voice Speakers & Speaker Strobes (Indoor Voice) WAN w/Live Voice LED Signage Outdoor Voice CAP Gateway Flame Detection CO/Smoke Detectors Manual Pull Stations

  47. ECS Summary • Multiple communication paths for emergency warning • Indoor and outdoor voice • LED Signs • Common Alerting Protocol interface to software products • Network-wide or single panel • Integration with third party systems • ONYX Series panels and ONYXWorks are UL2572 listed • ONYXWorks is the first UL2572 listed Central Control Station Deliver the right MESSAGE… at the right TIME… to the right AUDIENCE

  48. Network Solutions

  49. NOTI-FIRE-NET • Unites multiple NOTIFIER intelligent fire alarm control panels as one • LAN or WAN • Connect using wire, fiber or IP • Industry leading network node/panel capacity – up to 200 nodes! • All panels operate independently, yet cohesively, for unified response • Enhanced survivability – communications loss will not compromise life safety • Network-wide display and control Backbone of a robust Emergency Communications System

  50. NOTI-FIRE-NET Applications Universities Offices Hotels Airports Hospitals Schools

More Related