Dipole Stability Comparison WP08 / WP09. Natalia Emelianenko. Objective. Verify the dipole stability over time. How does the movement of D points triangle between the measurements at WP08 and WP09 depend on the time interval between the two measurements ?. Data for the Analysis.
E N D
Dipole StabilityComparison WP08 / WP09 Natalia Emelianenko
Objective Verify the dipole stability over time. How does the movement of D points triangle between the measurements at WP08 and WP09 depend on the time interval between the two measurements ?
Data for the Analysis Table CRYOGEO_D_POINTS – steps from WP09. We take the last measurement at WP09: select * from CRYOGEO_D_POINTS A where not exists (select 1 from CRYOGEO_D_POINTS where magnet_nu = A.magnet_nu and step > A.step)
Reference Measurement at WP08 In the table CRYOGEO_D_POINT for each measurement the reference measurement at WP08 is given: MEAS_ID, REFERENCE_MEAS There are 2 records for each measurement: MEAS = 'end carto‘–result from WP09 MEAS = 'fidu‘– result from WP08
D Points Triangle: Move and Rotation Move by X and Z can be found from the equations: x = a + x` cos φ - y` sin φ y = b + x` sin φ + y` cos φ Rotation: φ = arctg (z10’ - z9’) / (x10’– x9’)– arctg (z10 - z9) / (x10– x9) z D11 D10` b φ a x D9 D10
Correlation Between Sides Movement by X Rotation Movement by Z Correlation coefficients: X 0.36 Z 0.18 Angle 0.42
Sides Plotted Separately Average dX over 50 days
Middle Point Movement by X and Z D11 D10 D9
Summary on All Firms, All Steps, Both Sides X Move Z Move Rotation connection side lyre side
X Move: Steps Last step – WP09-WELD connection side lyre side Last step – WP09B-WELD
To Be Continued… If needed