Lateral offsets for multimode fiber (MMF) connectors part 1 Al Brunsting & Rick Pimpinella

Lateral offsets for multimode fiber (MMF) connectors part 1 Al Brunsting & Rick Pimpinella Panduit Corporation 17301 Ridgeland Avenue Tinley Park, IL 60477 Voice: 708-532-1800/888-506-5400 Fax: 708-532-1811 www.panduit.com. Background.

Download Presentation

Lateral offsets for multimode fiber (MMF) connectors part 1 Al Brunsting & Rick Pimpinella

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Lateral offsets for multimode fiber (MMF) connectors part 1 Al Brunsting & Rick Pimpinella Panduit Corporation 17301 Ridgeland Avenue Tinley Park, IL 60477 Voice: 708-532-1800/888-506-5400 Fax: 708-532-1811 www.panduit.com Panduit Corp.

  2. Background Simulations for connector lateral offsets are required to specify maximum connector insertion loss. A worst-case MMF lateral offset of 7.0m is currently being used. Based on a large comprehensive set of ferrule measurements and fiber specifications, we calculated connector lateral offsets using probability density functions (PDF). From this study it can be assumed that at least 95% of the lateral offsets in the field are less than or equal to 6.0m. Panduit Corp.

  3. Simulation theory Vectors for lateral offsets of a MMF connector (not to scale). Panduit Corp.

  4. Simulation theory (cont.) Resultant vector, S, is the sum of its 3 component vectors S = S1 + S2 + S3 S = simulated lateral offset for one of the two connectors in a MMF connection. Component offsets and connector rotations are accommodated in this simulation. x and y components of S: Sx = |S1| + |S2|cos2 + |S3|cos3 Sy = |S2|sin2 + |S3|sin3 From Slide 2 x-y coordinate system chosen so that 1 = 0. Panduit Corp.

  5. Simulation theory (cont.) 2 & 3 independently take on 6 values of 0, 60, 120, 180, 240, & 300. Mean and standard deviation (SD) for each of |S1|, |S2|, & |S3| come from Panduit measurements and MMF spec. (TIA/EIA-492AAAA-A, January 1998, Table 1). There are 5 indep. variables (2, 3, |S1|, |S2|, & |S3|). For each simulation there are 6*6*5*5*5 = 4500 resultant vectors, (S). Each S will have a statistical wt. Distribution of S‘s & associated wts. give final lateral offset PDF for one connector. Multiply offsets by SQRT(2) to simulate two connectors (one connection). Panduit Corp.

  6. Simulation theory (cont.) • SD for |S2| has 3 RMS components: • Measured ferrule ID SD. • Specified MMF cladding diameter OD. • Secondary effects: specified cladding non-circularity & alignment sleeve (est. from Panduit measurements). All taken to be 0.50mm. Each magnitude (|S1|, |S2|, |S3|) has 5 values (Sa, Sb, Sc, Sd, Se) = (mean – 2*SD, mean – SD, mean, mean + SD, mean + 2*SD). Correspond. stat. wts. (wi) = (0.135, 0.607, 1.000, 0.607, 0.135). Panduit Corp.

  7. An example Consider Supplier 2 & 1 case of 4500 simulated cases: Angles: 2 = 120, 3 = 240 |S1| = 0.14m (mean – 2*SD), w1 = 0.135 |S2| = 0.59m (mean – 2*SD), w2 = 0.135 |S3| = 1.00m, w3 = 0.607 (mean + SD) Results: Total stat. Wt. = 0.135*0.135*0.607 = 0.011 From Slide 4: Sx = -0.655, Sy = -0.355, |S| = 0.745m. Panduit Corp.

  8. Values for |S1|, |S2|, & |S3| Note: (|S1|, |S2|, |S3|) depends on (ferrule only, ferrule & MMF, MMF only). Sa 0. Tolerances for MMF are assumed to be at 3*SD. Some measurements, dimensions, and tolerances must be divided by 2 to convert from diameter to radius. Panduit Corp.

  9. Panduit measurements. (Eccent., OD, ID) are (eccentricity, outside diameter, inside diameter)m N = no. of ferrules measured. The three middle columns give mean  SD. 3050 ferrules were measured. Panduit Corp.

  10. Lateral offset PDF. Simulation giving the relative probability that the connection has a give lateral offset, |S|. Cumulative frequency is more useful for conclusions. Panduit Corp.