1 / 16

Observatory data: Quality and use in repeat station data reduction 

Observatory data: Quality and use in repeat station data reduction . Mioara Mandea (1) , Monika Korte (1) , Nils Olsen (2) (1) GeoForschungsZentrum Potsdam, Germany (2) Danish National Space Center, Copenhagen, Denmark. With thanks to

Download Presentation

Observatory data: Quality and use in repeat station data reduction 

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Observatory data: Quality anduse in repeat station data reduction  Mioara Mandea(1), Monika Korte(1), Nils Olsen (2) (1) GeoForschungsZentrum Potsdam, Germany (2) Danish National Space Center, Copenhagen, Denmark With thanks to H.-J. Linthe, J. Haseloff, J. Schulz, K. Tornow, A. Glodeck, I. Matthes, M. Krüger

  2. Importance of observatory data for repeat stations • Observatory variation recordings necessary for repeat station datareduction • Observatory annual means are based on hourly means • Observatory annual means are used for repeat station data reduction to “annual means” • Errors in observatory data can map directly into repeat station “annual means” C(xi,tmean) = C(xi,ti) – C(O,ti) + C(O, tmean) Repeat station“annual mean”of component C Repeat stationmeasurementvalue at time ti Observatoryannual meanof component C Observatoryrecording attime ti

  3. Overview over missing data • Mean daily variation per year and observatory • Comparison to CM4 model • Intercomparison of observatories This project: quality check of global observatory annual means • Aim:A high-quality set of global observatory hourly mean values for scientific studies, 1st step: 1995 to current (2003) • Data base:hourly means data base of WDC C1 for Geomagnetism, Copenhagen(now at WDC Edinburgh) • Problem:Data in the data base may contain errors- outliers- unreported base line jumps- uncorrected base line drifts • Strategy:- check all data for problems- compile a list of detected problems- encourage individual observatories to correct their data check all data for problems

  4. CHAMBON LA FORET (CLF) NIEMEGK  (NGK) Intercomparison of observatories

  5. Intercomparison of observatories X (nT) Y(nT) Z(nT) OBS 1 OBS 2 Difference • Differences due to inhomogeneous external and induced fields depending on distance between observatories and magnetic activity • Only slow variations due to secular variation (~linear) • No sudden jumps, no strong slow variations on sub-annual scale (baseline!)

  6. Intercomparison of observatories GOLUMD (GLM) LANZOU  (LZH)

  7. Jump ? Intercomparison of observatories X (nT) Y(nT) Z(nT) OBS 1 OBS 2 Difference Jump

  8. Intercomparison of observatories PANAGJURISHTE (PAG) ISTANBUL (ISK) SURLARI (SUR)

  9. Outlier ? Baseline Drift Baseline Drift Outlier ? Technical disturbance ? Jump ? Intercomparison of observatories X (nT) Y(nT) Z(nT) OBS 1 OBS 2 Difference

  10. Outlier ? Baseline Drift Baseline Drift Outlier ? Technical disturbance ? Jump ? Intercomparison of observatories X (nT) Y(nT) Z(nT) OBS 1 OBS 2 Difference Problems in ISK Problems in SUA

  11. Relevance for repeat station data C(xi,tmean) = C(xi,ti) – C(O,ti) + C(O, tmean) Repeat station“annual mean”of component C Repeat stationmeasurementvalue at time ti Observatoryannual meanof component C Observatoryrecording attime ti 1. Jumps within the year: - annual means incorrect (if jump not corrected)- C(O,ti) and annual means might be at different levels (if jump corrected for annual mean, but not in original variation data) 2. Base line drifts: - annual mean incorrect- reduction from a certain time of measurement to annual mean incorrect

  12. Tables of identified problems

  13. Comparison to CM4 model CM4: quiet time model modulated with indices Dst and F10.7 solar flux(Sabaka et al., 2004)

  14. Comparison to CM4 model - Differences Base line problem? CM4: quiet time model modulated with Dst and F10.7 solar flux indices (Sabaka et al., 2004)

  15. High latitudes • Problem: • Strong external variations • differ a lot from year to year • differ a lot between observatories • are not sufficiently described by CM4

  16. Conclusions • Most of the geomagnetic hourly mean values stored at the WDC C1 are of good quality but some erroneous data exist in the data base. • Comparisons of mean daily variations per year, intercomparisons between neighbouring observatories and comparisons to global models are useful methods to detect different kinds of problems. • For high geomagnetic latitudes and very remote observatories the detection of erroneous data is very challenging and not possible to the same degree of accuracy as for closely adjacent observatories at lower latitudes. • Tables and plots of identified problems are available on a website.http://www.gfz-potsdam.de/pb2/pb23/index_e.html, under link Projects: Global quality check of observatory data • However, we generally cannot explain the sources of errors. • We strongly encourage each observatory with some erroneous data to make every effort to understand the origin of the problems, correct their data and re-submit improved data to the WDC. • Repeat station data quality also depends on observatory data quality