1 / 19

Confidential Ink Management Solution for TN.59 Ink Management Solution Machine 75 and Above

This presentation covers an updated procedure for calibrating the weigh system of the TN.59 Ink Management Solution Machine 75 and above, which includes a GUI and 10-liter ink tanks. It features automatic ink weighting and a user-friendly GUI interface.

marylinm
Download Presentation

Confidential Ink Management Solution for TN.59 Ink Management Solution Machine 75 and Above

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TN 59 Ink Management Solution Machine 75 and Above

  2. Overview • This presentation covers an updated procedure for calibrating the weigh system. Confidential

  3. Ink Management Solution • Includes GUI and 10 liter ink tanks • Features • Enables TJ customers to monitor their ink consumption via the GUI and to have a better workflow with new 10 liter ink tanks. • Automatic Ink weighting – Ultimate digital ink management control allows controlling the precise ink usage. • GUI interface – Simple, user friendly; saves training time and easy to learn and handle. Confidential

  4. Ink Management Solution (cont.) Confidential

  5. Weigh System Confidential

  6. Weigh Controller • Located on the right hand side inside the CCB Box. • Stand alone controller that can measure 8 weights. • Supplied with 12VDC for the controller operation. The board produces 5VDC. • Communicates with the computer’s COM1 via RS422 port (ACB).CCB Board WEIGH CONTROLLER. • Accuracy weighing of ±50 gram. Confidential

  7. WEIGH CONTROLLER CCB BOARD Weigh Controller (cont.) Confidential

  8. Load Cell (Weigh sensor) • There are 7-load cells in the system, six for each color and one for the waste container. • The waste system will stop automatically when the load cell reads 10L. • The load cell is based on the principle of a bridge resistor. • The changes of the resistance in the bridge resistors is transferred to the weigh controller. Confidential

  9. Load Cell (cont.) Confidential

  10. How to Calibrate the Weigh System • The weigh system comes already calibrated in the integration stage. • If there is a need to replace the Load Cell (Weigh sensor) or the Weigh controller at the customer’s site, calibrate the weigh system as described below. Confidential

  11. Step 1: Calibrate the Zero Weight • All load cells must be connected to the weigh board and the optional connection #8 must be with the short plug. • Verify that there are no ink containers on the load cell, or any other weighs. • Use KVM measuring tool (DC) to calibrate the zero weigh for all the colors, see WEIGH CONTROLLER HARDWARE ADJUSTMENTS shown below. • Example: • For the cyan color (Channel 1), put the negative probe at the common test point TP_C, and the positive probe at the TP1 test point. • Use potentiometer R149 to calibrate the zero point. Confidential

  12. Step 2: Calibrate the Scale • In this calibration we are calibrating the relation between the weigh and the voltage. • Place a weight (5 or 10 liter ink container). • The measured voltage (X) that we will need to obtain at the test point is related to the weigh (A) that we put on the load cell • 12.5 KG = 2.5V • X = A (Weigh) X 2.5 (V) / 12.5 (KG) • Example: • The 5L ink containers weigh 5.2KG (Tested), the voltage needed to be calibrate at the potentiometer scale for all the Channels is 1.04V. Confidential

  13. Weigh Controller Hardware Adjustments Confidential

  14. Short Plug Waste Magenta Light Cyan Light Black Yellow Magenta Cyan Weigh Controller Hardware Adjustments (cont.) Confidential

  15. Step 3: Software Calibration • Check the Zero weight: • Remove all the weights or Ink tanks from their socket • In the RTRun software go to Tools > Color Box > Weight Calibration, and mark the Zero weight. • Push color-by-color Calibration tab and Save tab when done. • Push the Test tab and verify that you get 0.00 for all colors and waist. • Repeat above steps again if necessary. Confidential

  16. Step 3: Software Calibration (cont.) • Check the Full weight: • Place all the Full ink containers in their sockets (10 lit.). • In the RTRun software Go to RTRun > Tools > Color Box > Weight Calibration • Select the Full Weight option. • In the Real Weight (gr) box, enter the actual (measured) weight of the ink container. • Example: for a full 5-liter container, enter 5200, and for a full 10-iter container, enter 10400 (gr). Confidential

  17. Step 3: Software Calibration (cont.) • Check the Full weight: • Push color-by-color the Calibration tab and Save tab when done. • Push the Test tab and verify that you get the correct weight – the same as you entered in the Real Weight box. • Repeat step B if necessary. Confidential

  18. Step 3: Software Calibration (cont.) Confidential

  19. Checking the Weight in the Application Software and in the RTRun Software Confidential