190 likes | 199 Views
This presentation covers an updated procedure for calibrating the weigh system of the TN.59 Ink Management Solution Machine 75 and above, which includes a GUI and 10-liter ink tanks. It features automatic ink weighting and a user-friendly GUI interface.
E N D
TN 59 Ink Management Solution Machine 75 and Above
Overview • This presentation covers an updated procedure for calibrating the weigh system. Confidential
Ink Management Solution • Includes GUI and 10 liter ink tanks • Features • Enables TJ customers to monitor their ink consumption via the GUI and to have a better workflow with new 10 liter ink tanks. • Automatic Ink weighting – Ultimate digital ink management control allows controlling the precise ink usage. • GUI interface – Simple, user friendly; saves training time and easy to learn and handle. Confidential
Ink Management Solution (cont.) Confidential
Weigh System Confidential
Weigh Controller • Located on the right hand side inside the CCB Box. • Stand alone controller that can measure 8 weights. • Supplied with 12VDC for the controller operation. The board produces 5VDC. • Communicates with the computer’s COM1 via RS422 port (ACB).CCB Board WEIGH CONTROLLER. • Accuracy weighing of ±50 gram. Confidential
WEIGH CONTROLLER CCB BOARD Weigh Controller (cont.) Confidential
Load Cell (Weigh sensor) • There are 7-load cells in the system, six for each color and one for the waste container. • The waste system will stop automatically when the load cell reads 10L. • The load cell is based on the principle of a bridge resistor. • The changes of the resistance in the bridge resistors is transferred to the weigh controller. Confidential
Load Cell (cont.) Confidential
How to Calibrate the Weigh System • The weigh system comes already calibrated in the integration stage. • If there is a need to replace the Load Cell (Weigh sensor) or the Weigh controller at the customer’s site, calibrate the weigh system as described below. Confidential
Step 1: Calibrate the Zero Weight • All load cells must be connected to the weigh board and the optional connection #8 must be with the short plug. • Verify that there are no ink containers on the load cell, or any other weighs. • Use KVM measuring tool (DC) to calibrate the zero weigh for all the colors, see WEIGH CONTROLLER HARDWARE ADJUSTMENTS shown below. • Example: • For the cyan color (Channel 1), put the negative probe at the common test point TP_C, and the positive probe at the TP1 test point. • Use potentiometer R149 to calibrate the zero point. Confidential
Step 2: Calibrate the Scale • In this calibration we are calibrating the relation between the weigh and the voltage. • Place a weight (5 or 10 liter ink container). • The measured voltage (X) that we will need to obtain at the test point is related to the weigh (A) that we put on the load cell • 12.5 KG = 2.5V • X = A (Weigh) X 2.5 (V) / 12.5 (KG) • Example: • The 5L ink containers weigh 5.2KG (Tested), the voltage needed to be calibrate at the potentiometer scale for all the Channels is 1.04V. Confidential
Weigh Controller Hardware Adjustments Confidential
Short Plug Waste Magenta Light Cyan Light Black Yellow Magenta Cyan Weigh Controller Hardware Adjustments (cont.) Confidential
Step 3: Software Calibration • Check the Zero weight: • Remove all the weights or Ink tanks from their socket • In the RTRun software go to Tools > Color Box > Weight Calibration, and mark the Zero weight. • Push color-by-color Calibration tab and Save tab when done. • Push the Test tab and verify that you get 0.00 for all colors and waist. • Repeat above steps again if necessary. Confidential
Step 3: Software Calibration (cont.) • Check the Full weight: • Place all the Full ink containers in their sockets (10 lit.). • In the RTRun software Go to RTRun > Tools > Color Box > Weight Calibration • Select the Full Weight option. • In the Real Weight (gr) box, enter the actual (measured) weight of the ink container. • Example: for a full 5-liter container, enter 5200, and for a full 10-iter container, enter 10400 (gr). Confidential
Step 3: Software Calibration (cont.) • Check the Full weight: • Push color-by-color the Calibration tab and Save tab when done. • Push the Test tab and verify that you get the correct weight – the same as you entered in the Real Weight box. • Repeat step B if necessary. Confidential
Step 3: Software Calibration (cont.) Confidential
Checking the Weight in the Application Software and in the RTRun Software Confidential