1 / 20

2009 Ductless Mini Splits

2009 Ductless Mini Splits. “Affordable Comfort”. Quietside Mini Splits . Cooling Only Single Zone High Wall 9,000 to 24,000 Btu/h – 13 SEER Heat Pump Single Zone High Wall 9,000 to 24,000 Btu/h – 13 SEER & 7.7 HSPF Heat Pump Dual Zone High Wall

mason
Download Presentation

2009 Ductless Mini Splits

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2009 Ductless Mini Splits “Affordable Comfort”

  2. Quietside Mini Splits • Cooling Only Single Zone High Wall 9,000 to 24,000 Btu/h – 13 SEER • Heat Pump Single Zone High Wall 9,000 to 24,000 Btu/h – 13 SEER & 7.7 HSPF • Heat Pump Dual Zone High Wall 2 x 9,000 Btu/h & 2 x 12,000 Btu/h – 15 SEER & 7.7 HSPF

  3. Single Zone Cooling Only • QSCE 091, 121, 181 & 241 Model series • 13 SEER efficiency • Low Noise levels • Small Indoor and Outdoor unit footprints • 50ft line set lengths • 20ft vertical separation included • Hi Voltage Power and Control wiring required between Outdoor and Indoor units

  4. Single Zone Cooling Only • Wireless Remote control with Auto, Cool, De-hum, Fan modes and Auto Restart features • Flare refrigerant connections • Environmentally friendly R410A refrigerant • 5/16” Gauge access port to differentiate for R410A refrigerant – NEEDS an adaptor #R410A-ADPT

  5. Single Zone Heat Pump • QSHE 091, 121, 181 & 241 • 13 SEER and 7.7 HSPF efficiency • 50ft Line Set length • 20ft Vertical Separation included • Demand defrost initiated by Outdoor unit coil temperature sensor • Capillary expansion devices are located in Outdoor unit

  6. Single Zone Heat Pump • Auto swing feature on air direction louvers • High Efficiency Toshiba Rotary compressors • Environmentally friendly R410A refrigerant • Flare connections on Indoor and Outdoor unit, gauge access is also 5/16” • Low Noise levels, especially for the Outdoor units

  7. Dual Zone Heat Pump • QSHD 181 and 241 • 2 x 9,000 Btu/h and 2 x 12,000 Btu/h systems • SINGLE Inverter drive compressor provides refrigerant flow for both Indoor units • Up to 15.6 SEER and 8.1 HSPF • Units can operate independently but one unit cannot be in Heating when the other is in cooling

  8. Dual Zone Heat Pump • 50ft max line set including a vertical separation of 20ft to each Indoor unit • R410A refrigerant • Cooling operation down to 32 DegF ambient • Heating operation down to 5 DegF • Inverter Drive compressor controls capacity based on Indoor unit operation, set points, ambient temperature and Indoor coil temperatures

  9. Dual Zone - Outdoor • Electronic Expansion Valves control refrigerant flow to each Indoor unit providing precise control across all conditions • Inverter Drive compressor is covered in a blanket to reduce noise levels • System uses demand defrost, with both units having to defrost at the same time even if one does not need it

  10. Dual Zone Outdoor 24k • 24k system uses a manifold style connection with a single set of service valves, the 18k unit has dual service valves 18k 24k

  11. Dual Zone • SINGLE wire low voltage communication signal between Indoor units and Outdoor units Separation required to the high voltage power wiring • Multiple fault codes displayed on the Indoor units

  12. Accessories • Line Sets for Single zones – 25ft and 50ft lengths, both lines are insulated and include 14-7 Interconnecting wire • Interconnecting Wire, 14-7 • 5/16” Adaptor to access Refrigerant circuit

  13. Accessories • Line Sets for Dual zones – 25ft and 50ft lengths, both lines are insulated and include 14-3 and 16-2 Shielded Interconnecting wire • 2 Line Sets needed per system

  14. Accessories • Low Ambient Control MANDATORY for all Quietside unit Data Room applications or when using cooling below 65 DegF Ambient • Condensate Pump for unit installations on interior walls – Pumps are available in several styles with and without covers • Condenser Brackets

  15. Other items to sell with a Ductless • Line Set covers, Quietside recommends the Slimduct covers • Condenser Pad • Electrical Disconnect and Whip • Condenser feet/risers • Condensate Hose extension and/or trap for humid areas, we recommend rigid piping whenever draining condensate anything but vertical

  16. Quietside Unit Warranty • 5 Years Compressor • 1 Year all other parts, including refrigeration system parts • 90 Days limited labor from date of start up • All warranties commence on date of installation • Warranty parts are shipped ground on receipt of a completed warranty claim form

  17. Thanks for listening Any Questions???

More Related