200 likes | 357 Views
Smart Power Strips in Commercial Office Applications. RTF August 30, 2011. Goal Today. To update UES estimates and move provisionally deemed smart strip measures to active status for commercial office applications Using updated savings from BPA engineering research. Background.
E N D
Smart Power Strips in Commercial Office Applications RTF August 30, 2011
Goal Today • To update UES estimates and move provisionally deemed smart strip measures to active status for commercial office applications • Using updated savings from BPA engineering research
Background • RTF Provisionally deemed smart power strips in a commercial office in March 2010 • 100 kWh • $20/unit • 4 year Measure Life • RTF approved Research Plan • 50 unit sample • 2 week pre/post metering • Collect information on equipment plugged in and settings
Smart Power Strips • Resemble traditional power strips, but have outlets with different functionalities. • Control outlet and controlled outlets • Some also have outlets that will always remain on • Load Sensor • Occupancy Sensor
Smart Power Strips • Load Sensor • When a control device is turned off or enters sleep mode, the Smart Power Strip cuts power to the controlled peripherals: items such as printers, heaters, speakers. • Occupancy Sensor • The occupancy sensor cuts power to the controlled peripherals: items such as printers, heaters, speakers.
BPA Metering Study • Details about the research activities • A total of 48 smart strips installed • Installed at Ross Complex, Vancouver, WA • Approximately 3 weeks baseline and post metering time during April/May 2011 • Kill-A-Watt Meters used for data collection • ‘Current Sensing’ Smart Power Strip was installed • Load sensor device
Results Summary • Savings details • Sample size = 45 cubicles/offices • Average Savings per year per cubicle = 132 KWh • Includes removal of 4 units during research period • Median value = 80 KWh • 80% Confidence Interval = 36.34
Results – Frequency Distribution Printer 1057 kwh savings
Results – # of Devices Plugged In * Number of devices plugged in is in addition to computer and monitor
Measure Cost and Measure Life • Cost • $24.99 per unit, Non-Volume, Retail • Labor cost - $3.50 (10 Minutes per unit at $20/hour for installation) • Measure Life • 4 years
Measure Requirements • Must be installed in commercial offices occupied a minimum of 50 hour per week • Must be at least 1 device plugged into strip, in addition to desktop/laptop/monitor • Okay to use with Network PC management as long as more than desktop/monitor plugged in
Continued Research • Follow up with metered units periodically to check if still installed • BPA to conduct metering on additional 24 work spaces with same metering process • Study using occupancy sensor devices
Motion for Approval • Motion to approve UES estimate to active status for smart power strips (load and occupancy sensing) in commercial office applications, with a sunset date of September 2013 (2 years)