40 likes | 110 Views
MATERIAL SAFETY DATA SHEET (MSDS). SECTION 1 - GENERAL INFORMATION. Product Name: Valve Regulated Lead Acid (VRLA) Batteries / Lead acid battery. Manufacturer: GREAT POWER BATTERY TECHNOLOGY CO.,LTD. Guoxia Building,Longguan Road,Longhua Town,Bao’an District,Shenzhen City
E N D
MATERIALSAFETYDATASHEET(MSDS) SECTION1-GENERALINFORMATION Product Name: Valve Regulated Lead Acid (VRLA) Batteries / Leadacidbattery Manufacturer: GREAT POWER BATTERY TECHNOLOGY CO.,LTD Guoxia Building,Longguan Road,Longhua Town,Bao’an District,Shenzhen City Guangdong Province, China. Tel: (+86-755) 2900 8403 Fax:(+86-755) 2807 8753 Email:info@greatpowerbattery.com Responsiblepersons:QARepresentative,ManagingDirector SECTION2-COMPOSITION/INFORMATIONONINGREDIENTS SECTION3--HAZARDIDENTIFICATION Odour:Notapplicable Appearance:Articleasdescribedabove WeightHighDensity/Goodliftingtechniquerequired Hazardsrefertointernalcomponent,i.e.leadandsulphuricacid Contactwitheyes:Causesirritation Contactwithskin:Maycausedermatitis Inhalation:Maycauseirritation Ingestion:Cancausedamagetothekidneys
SECTION4-FIRSTAIDMEASURES Inhalation: Removepatienttofreshair.Seekmedicalattentionifirritationpersists. :Ifsubstancehasgotintoeyes,immediatelywashoutwithplentyofwaterforatleast15minutes. Removecontaminatedclothingimmediatelyanddrenchaffectedskinwithplentyof Eyes Skin : water,thenwashwithsoapandwater. Ingestion:Donotinducevomiting. If conscious drink large amounts of water/milk. Obtain medical attention.Never give anything by mouth to an unconscious person. SECTION5-FIREFIGHTINGMEASURES Auto-ignitionpoint(Hydrogen)580ºCat760mmHg Wearpositive-pressurebreathingapparatus Incaseoffireusefoam,carbondioxideordryagent(S43) FlashpointHydrogen259ºC FlammableLimitsinair,Lower4.1% %by3/4vol.(Hydrogen) Fire/explosion Hydrogenandoxygengasesareproducedinthecellsduringnormalbatteryoperation(hydrogenis flammableandoxygensupportscombustion). SECTION6-ACCIDENTALRELEASEMEASURES ImmediateActions: CleanUpActions: Shutoffallignitionsources Neutralisewithsodaash Placeinappropriatecontainer Ventilatearea Donotemptyintodrains(S29) SECTION7-HANDLINGANDSTORAGE Undernormalconditionsofbatteryuse,internalcomponentswillnotpresentahealthhazard Handling: Storage: Keepawayfromheatandsourcesofignition Washhandsthoroughlyafteruse Avoidsparks Avoidcontactwithmetaljewelleryandwatchesetc. DoNotRemoveVentCaps Donotdoublestackindustrial Keepincoolanddry&Protectfromheat. Storeleadacidbatterieswithadequateventilation. Roomventilationisrequiredforbatteriesutilisedforstandbypowergeneration. Neverre-chargebatteriesinanunventilated,enclosedspace.
SECTION8-EXPOSURECONTROLSANDPERSONALPROTECTION Personalprotection:Wearsafetyshoeswithtoeprotector. Whereinternalcomponentsareliberateduserubberorneopreneboots. Weargoggles/safetyglassesgivingcompleteeyeprotection. excessiveaircontaminationexists. WearPVCmitts,glovesorgauntlets. ExposureLimits: LeadOES/LTEL-ppm0.15mg/m3 LeadDioxideOES/LTEL-pmm0.15mg/m3 SECTION9-PHYSICALANDCHEMICALPROPERTIES Odour: Appearance: Stateundernormaltemp: Flashpoint(Hydrogen): Internalcomponents pH-(Sulphuricacid): Boilingpoint: (at760mm/Hg) Meltingpoint: Vapourpressure: Vapourdensity: Specificgravity: Auto-ignitionpoint: Notapplicable. SealedValveRegulatedleadAcidBattery Solid 259ºC 1.3. BatteryElectrolyte110ºC,Lead1755ºC Lead327.4ºC 11.7 BatteryElectrolyte3.4,(air=1) BatteryElectrolyte1.3g/cm3.(water=1) 580ºdegCat760mm/Hg. SECTION10-STABILITYANDREACTIVITY VRLABatteriesareconsideredstableatnormalconditions. Keepawayfromheatandsourcesofignition. Incompatiblewithreducingagents.Incompatiblewithorganicagents. Decompositionproductsmayincludehydrogen. Decompositionproductsmayincludesulphuroxides. SECTION11-TOXICOLOGICALINFORMATION Dangerofcumulativeeffects.(R33) Maycausesevereirritation. Maycausegastro-intestinaldisturbances. Cancausedamagetothemucousmembranes. SECTION12-ECOLOGICALINFORMATION Ecotoxicology-noinformationavailable
SECTION13-DISPOSALCONSIDERATIONS Classification: Disposalconsiderations: Thismaterialand/oritscontainermustbedisposedofashazardouswaste. Donotdischargeintodrainsortheenvironment,disposetoanauthorisedwaste collectionpoint. SECTION14-TRANSPORTINFORMATION WeherebycertifythatGreat Power BatteryallseriesofMaintenanceFreeRechargeableSealedLeadAcid batteriesconformtotheUN2800classificationas“Batteries,Non-Spillable,andelectricstorage”asaresult ofpassingtheVibrationandPressureDifferentialTestdescribedinDOT[49CFR173.159(d)andIATA/ICAO [SpecialProvisionA67]. Great Power BatteryhavingmettherelatedconditionsareEXEMPTfromhazardousgoodsregulationsforthe purposeoftransportationbyDOT,andIATA/ICAO,andthereforeareunrestrictedfortransportationbyany means. SECTION15-REGULATORYINFORMATION Classificationandlabeling.Notclassifiedashazardousforsupply SECTION16-OTHERINFORMATION Undernormalconditionsofbatteryuse,internalcomponentswillnotpresentahealthhazard.The informationcontainedinthisSafetyDataSheetisprovidedforbatteryelectrolyte(acid)andlead,for exposurethatmayoccurduringbatteryproductionorcontainerbreakageorunderextremeheatconditions suchasfire. ThisSafetyDataSheetandtheinformationthereindoesnotconstitutetheuser’sownassessmentofwork placeriskasrequiredbyotherHealth&Safetylegislation. FORM MSDS REV. 15/01/2014