An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Major Components for Energy Audit for HVAC Systems are: • Chillers • Pumps • Motors • Cooling Towers • Air Handling Units Check us at http://www.mgcs.net.in/hvac_energy_audit.php

  2. CASE STUDY 1: COOLING TOWER. Check us at http://www.mgcs.net.in/hvac_energy_audit.php

  3. Sample case study for audit of cooling tower. With our precise and scientific instruments, we have analyzed below mentioned data for two number of cooling towers installed at client side. Check us at http://www.mgcs.net.in/hvac_energy_audit.php

  4. Check us at http://www.mgcs.net.in/hvac_energy_audit.php

  5. Technical Evaluation & Findings: This is of Natural Air cooling Tower with 6 rows and each row has 14 nozzles. In cooling tower-1 only 5 rows are operation and in other cooling tower -2 all 5 rows are in operation. Height of the cooling Tower is 4.2 m. No chemical additives are added to maintain the TDS. Chiller condensing water is been cooled here, the main criteria is outlet temperature which should be 28°C but as the cooling tower completely covered by building it will affect cooling water outlet temperature. Check us at http://www.mgcs.net.in/hvac_energy_audit.php

  6. Proposed System: The cooling tower need to shift to terrace where there is no obstacles so the air will flow from down wards and cooling water temperature will be below 28°C. Check us at http://www.mgcs.net.in/hvac_energy_audit.php

  7. We have got BEE (Bureau of Energy Efficiency) Certified Energy Auditors on board to help you on Energy Management System • We use all gadgets and instruments from leading brands across the globe for fine accuracy and precision Check us at http://www.mgcs.net.in/hvac_energy_audit.php

  8. This way, we helped our client in saving money by taking the corrective action through our detailed auditing for the chiller plants. Note: The above information is only for knowledge sharing and MGCS has its sole right and proprietorship of above technical data. Check us at http://www.mgcs.net.in/hvac_energy_audit.php

  9. Energy Conservation-need of the hour Contact us now & save on Energy & Money Write us at hina.gupta@mgcs.net.in for any query L -011-49040941/42/43 Subscribe and check our blog for more such case studies and updates http://www.mgcs.net.in/blog/ Check us at http://www.mgcs.net.in/hvac_energy_audit.php