180 likes | 328 Views
Recovered Energy, Inc. presents The Recovered Energy System™. Objective: To Utilize the Most Advanced, Safe and Environmentally Friendly Process to Dispose of Waste Materials by Converting Them into Valuable Products. Turn a Liability into an Asset. Auto Shredder Residue. Paints & Solvents.
E N D
Recovered Energy, Inc.presentsThe Recovered Energy System™ Objective: To Utilize the Most Advanced, Safe and Environmentally Friendly Process to Dispose of Waste Materials by Converting Them into Valuable Products.
Turn a Liability into an Asset Auto Shredder Residue Paints & Solvents Oil Waste Appliances Medical Waste MSW Old Furniture Industrial Waste Tires Industrial Sludge Plastics Coal Fines Oily Water & Contaminated Soil Too Much Waste… and the Perfect Place for it!
Plasma Gasification Today’s Answer to a Vexing Problem: • Non-incineration Thermal Process that is State-of-the-art. • Employs very High Temperatures in an Oxygen-starved Environment. • Decomposes Waste Material into very Simple and Usable Molecules. • Results in Combustible Gas and Inert Slag. • Exceeds all Environmental Requirements.
Complete Destruction (8000 Deg F) Incomplete Destruction (1000-1500 Deg F) Incomplete Destruction (900-1200 Deg F) No Ash 20% Ash (by Weight) 30% Ash (By Weight) No Sorting Requires Sorting Requires Sorting Any Type of Waste Some Inorganics Some Inorganics Large Capacity Small Capacity Large Capacity No Tars or Furans Tars and Furans High Tars and Furans Max 12” MinusSize Maximum 30” Minus Size Maximum 2” Minus Size Very Low Emissions Medium Stack Emissions High Stack Emissions Not Impacted by Moisture Impacted by Moisture Impacted by Moisture Plasma Gasification:A Major Breakthrough Plasma Gasification Gasification Incineration
Process Flow Diagram Tipping Floor Waste Storage
Process Flow Diagram Heat Exchangers Plasma Gasifier Tipping Floor Waste Storage Vitrified Glass Metals
Steam Gas Clean Up System Fuel Gas HCL Sulfur Process Flow Diagram Heat Exchangers Plasma Gasifier Tipping Floor Waste Storage Vitrified Glass Metals
Process Flow Diagram Heat Exchangers Steam Turbine Multi- Effect Distillation (Optional) Steam Plasma Gasifier Tipping Floor Steam Gas Clean Up System Electricity Fuel Gas Waste Storage Gas Turbine Vitrified Glass Metals HCL Sulfur . Electricity Distilled Water (Optional) Complete Conversion
Multi-Effect Distillation Unit Process Flow Source Water 3.6% TDS 75º F 30 psig 4.05% TDS 88º F 15 psig Filter Condensing, Cooling & Dilution 78% Steam (.34 bara) 6.9% TDS 94º F 15 psig 12% Brine 22% 10% Distilled Water 10 TDS, 93º F, 30 psig Condensate Out
A Complete Job 100% Recovery • CO and H2 are Recovered into Electricity • Inorganics are Recovered into Glass • Metals are Recovered • Chlorine is Recovered into HCL • Sulfur is Recovered into Sodium Bisulfite • Boiler Stack Contains N, CO2 (Credit) and Water Steam Steam Turbine Heat Exchanger Plasma Gasifier MED Unit Gas Clean Up Steam Electricity Gas Turbine Metals Sodium Bisulfite HCL Distilled Water Vitrified Glass Electricity
The Recovered Energy SystemTMProven Technologies • Gasifier by Westinghouse with 25+ Years Experience
The Recovered Energy SystemTMProven Technologies • Gas Cleanup System by Turbosonic, Inc. with 300+ Installations
The Recovered Energy SystemTMProven Technologies • Power Generation Equipment by GE, the Industry Leader • Other Equipment from Well-known Suppliers of Standard Equipment
Protects and Improves the Environment • Allows for the Elimination of Landfills • Converts Waste into Usable Products • Air and Water Emissions are Below National and State EPA Standards • No Process Water Discharge
Total Environmental Protection Odors • Building has Negative Air Pressure • Compressor Pulls Process Air Through the Building • All Waste is Cycled Regularly • All Materials are Stored Indoors Noise • Building is Constructed to Suppress Operating Noise