1 / 31

Towards a Pulseshape Simulation / Analysis

Towards a Pulseshape Simulation / Analysis. Kevin Kr öninger, MPI für Physik GERDA Collaboration Meeting, DUBNA, 06/27 – 06/29/2005. Outline. Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005. SIMULATION. Simulation Overview I.

Download Presentation

Towards a Pulseshape Simulation / Analysis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Towards a Pulseshape Simulation / Analysis Kevin Kröninger, MPI für Physik GERDA Collaboration Meeting, DUBNA, 06/27 – 06/29/2005

  2. Outline Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  3. SIMULATION

  4. Simulation Overview I Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  5. Simulation Overview II • What happens inside the crystal? • Local energy depositions translate into the creation of electron-hole pairs • with Edep : deposited enery • Eeh : 2.95 eV at 80 K in Ge • Egap = 0.73 eV at 80 K → ¾ of energy loss to phonons • Corresponds to approximatly 600,000 e/h-pairs at 2 MeV • Due to bias voltage electrons and holes drift towards electrodes • (direction depends on charge and detector type) • Charge carriers induce mirror charges at the electrodes • while drifting <N> = Edep / Eeh → SIGNAL Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  6. Drifting Field / Bias Voltage I • In order to move charge carriers an electric field is needed • Calculate field numerically: • 3-D grid with spatial resolution of 0.5 mm • Define Dirichlet boundary conditions (voltage, ground) • → depend on geometry (true coxial? non-true coxial? etc.) • So far: no depletion regions, zero charge density inside crystal, • no trapping • Solve Poisson equation ∆φ = 0 inside crystal using a Gauss-Seidel • method with simultaneous overrelaxiation • Need approximatly 1000 iterations to get stable field • Electric field calculated as gradient of potential Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  7. Drifting Field / Bias Voltage II Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  8. Drifting Field / Bias Voltage III • Example: non-true coaxial n-type detector Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  9. Drifting Process Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  10. Mirror Charges – Ramo‘s Theorem • Ramo‘s Theorem: • Induced charge Q on electrode by point-like charge q is given by • Calculation of weighting field: • Set all space charges to zero potential • Set electrode under investigation to unit potential • Ground all other electrodes • Solve Poisson equation for this setup (use numerical method explained) Q : induced charge q : moving pointlike charge φ0 : weighting potential Q = - q · φ0(x) Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  11. Weighting Fields I x Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  12. Weighting Fields II • Example: true coaxial detector with 6 φ- and 3 z-segments φ = 0° φ = 90° φ = 180° φ = 270° z (Slices in φ showing ρ-z plane) y x Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  13. Preamp / DAQ • Drift and mirror charges yield charge as function of time • Preamp decreases accumulated charge exponentially, • fold in gaussian transfer function with 35 ns width • DAQ samples with 75 MHz → time window 13.3 ns • Example: (signal after drift) (signal after drift, preamp and DAQ) Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  14. Setups / Geometries / Eventdisplays I • Full simulation of non-true coaxialdetector Charge Charge electrode core Time Current Current electrode core Time Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  15. Setups / Geometries / Eventdisplays II Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  16. Setups / Geometries / Eventdisplays III • Full simulation of true-coxial 18-fold segmented detector electrodes core Charge Time Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  17. Analysis Approach

  18. Pulseshape Analysis in MC: Spatial Resolution I • Is it possible to obtain spatial information of hits from • pulseshapes? In principal YES! • Risetime of signal (10% - 90% amplitude) is correlated with radius • of hit due to different drift times of electrons and holes • Relative amplitude of neighboring segments is correlated to angle • Events with more than one hit in detector give ambiguities • Studied in Monte Carlo with 2-D 6-fold segment detector, • no DAQ, no sampling Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  19. Pulseshape Analysis in MC: Spatial Resolution II • Spatial information of radius and angle Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  20. Pulseshape Analysis: SSE/MSE Discrimination I • Do 0νββ signals differ from background signals? • Background mainly photons that Compton-scatter: multiple hits • in crystal → Multisite events (MSE) • Signal due to electrons with small mean free path: localized energy • deposition → Singlesite events (SSE) • Expect two ‘shoulders‘ at most from SSE and more from MSE • Count number of shoulders in current • Apply mexican hat filter with integral 0 and different widths (IGEX method) • Count number of shoulders: ≤2 : SSE • >2 : MSE Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  21. Pulseshape Analysis: SSE/MSE Discrimination II Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  22. Pulseshape Analysis: SSE/MSE Discrimination III • Fraction of SSE and MSE for different filter widths Identified as SSE Identified as MSE Fraction of Events Fraction of Events Filter width Filter width Separation of SSE/MSE in principle possible, combine with information from neighboring segments SSE MSE Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  23. Data to Monte Carlo Comparison

  24. Data to Monte Carlo Comparison I • Data from teststand (see X. Liu) • Later on used for SSE selection Work in progress Source Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  25. Data to Monte Carlo Comparison II • Teststand data vs. Monte Carlo Work in progress Energy [MeV] Energy [MeV] • General agreement • No finetuning yet • Next: pulseshapes without • any additional selection criteria Energy [MeV] Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  26. Data to Monte Carlo Comparison III • Comparison of pulseshapes Work in progress Data Monte Carlo Charge Charge Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  27. Data to Monte Carlo Comparison IV • Comparison of pulseshapes Work in progress Data Monte Carlo Current Current Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  28. Data to Monte Carlo Comparison V • Comparison of pulseshapes Work in progress Charge Current Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  29. Data to Monte Carlo Comparison VI • Comparison of pulseshapes Work in progress Current amplitude Charge amplitude Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  30. Data to Monte Carlo Comparison VII • Comparison of pulseshapes Work in progress Risetime [ns] Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  31. Conclusion • First approach towards a simulation of pulseshapes • Different geometries / fields available • Package available and linked to MaGe • Pulseshape analysis to further reduce background via • SSE/MSE identification is feasible → need sampling rate • as large as possible (1 GHz ↔ 1 ns possible?) • Data to Monte Carlo comparison using teststand data • yields coarse agreement → finetune parameters of simulation Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005