1 / 12

Hydro-implantation of Rigid IOLs in Manual Phaco (SICS) – A Safety and Efficacy Study

Hydro-implantation of Rigid IOLs in Manual Phaco (SICS) – A Safety and Efficacy Study. ^. Dr. Suvarna Bhagde Sadguru Netra Chikitsalaya, Chitrakoot. Introduction.

milica
Download Presentation

Hydro-implantation of Rigid IOLs in Manual Phaco (SICS) – A Safety and Efficacy Study

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hydro-implantation of Rigid IOLs in Manual Phaco (SICS) – A Safety and Efficacy Study ^ Dr. Suvarna Bhagde Sadguru Netra Chikitsalaya, Chitrakoot.

  2. Introduction • Classically, in a cataract surgery, IOL is implanted after the capsular bag is inflated and anterior chamber is formed with viscoelastic. • Problems with Viscoelastic– • Takes time to be removed completely from the eye • Often inadvertently left behind causing • Post-operative IOP spikes • Pseudo-anterior uveitis. • To circumvent these problems, we implanted rigid PMMA IOLs under a continuous irrigation of RL from the side-port in manual phaco surgery.

  3. Aim To study safety and efficacy of Hydro-implantation of rigid IOLs in manual phaco (SICS).

  4. Material and Method Nature of Study : Prospective, Non-controlled, Interventional Cohort Study Setting : SadguruNetraChikitsalaya, Chitrakoot Duration : February 2010 Inclusion : 130 eyes of 130 consecutive patients Exclusion : Patients with concomitant Glaucoma Previous intra-ocular surgery

  5. Results 130 eyes of 130 patients Average Age : 58.6 years (Range : 35 to 90 years)

  6. Types of Cataract Two cases of Hypermature Cataract showed Phacodonesis.

  7. Pre-Operative Picture

  8. Intra-Operative Picture

  9. Post-Operative Picture

  10. Discussion • There are no published studies on only Hydro-implantation of IOL in SICS surgery. Work has been done on Blumenthal Technique wherein also the IOL is implanted in visco-free setting by some workers1,2 • Hydro-implantation of IOL has been tried in Phacoemulsification3,4. • Following advantages of Hydro-implantation of IOL are seen: • No OVD-induced intraocular pressure elevation postoperatively • No risk of early capsular bag distension syndrome • Reduced post-operative anterior uveitis. • Improvements in surgical efficiency • Reduced surgical cost • Malik KP, Goel R. Manual of small incision cataract surgery. New Delhi: CBS publishers; 2003. Our technique of Small incision cataract surgery using anterior chamber maintainer: Modified Blumenthal technique; pp. 123–35. • Blumenthal M, Ashkenazi I, Fogel R, Assia EI. The gliding nucleus. J Cataract Refract Surg. 1993;19:435–7. • HarshulTak:Hydroimplantation: Foldable intraocular lens implantation without an ophthalmic viscosurgical device, J Cataract Refract Surg (2010)Volume 36, Issue 3, Pages 377-379 • Shimizu K, Kobayashi K, Takayama S, Zhaobin G:Preloaded injector for intraocular lens implantation without the use of ophthalmic viscosurgical devices. J Cataract Refract Surg. 2008 Jul;34(7):1157-60

  11. Conclusion Thanks Hydro-implantation of IOL is safe in experienced hands with minimal complications and acceptable results.

  12. Thanks Dr. Suvarna Bhagde Consultant, Oculoplasty Department Sadguru Netra Chikitsalaya, Chitrakoot. suvarnabhagde@gmail.com 9984902820

More Related