This presentation outlines the aims of the study, which include radiation monitoring, compatibility testing between detectors, determining average radiation dose in separate locations, and developing software for a self-built Geiger-Müller counter. The study also explores the possible use of the equipment on the NICA-MPD platform.

millerb
Download Presentation

Radiation Monitoring in the Working Area of the MPD Slow Control Electronic Equipment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. α, β, γ α, β, γradiation monitoring in the workingarea of the MPD Slow Control electronicequipment Alicja Jakubowska, Marta Robak, Anita Zagrobelnawarsaw university of technology,faculty of physics Supervisor: Nikita Dunin and engineering support Contact: ala.jakubowska@op.pl martarobak12@gmail.com a.zagrobelna97@gmail.com Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  2. Presentation outline Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  3. AIMS • α, β, γradiationmonitoring • Compatibility test betweenthreedetectors • Determingaverageradiationdose in threeseperatelocations • Developing software for self-bulit Geiger-Müller counter • Possible use on the NICA-MPD-PLATFORM Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  4. Ionizingradiation Ionizingradiationis radiation that carries sufficient energy to detach  electrons from atoms or molecules. Types of ionizingradiation: α, β, neutron particles, γ and X-rays, Picture from:https://www.mirion.com/learning-center/radiation-safety-basics/types-of-ionizing-radiation Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  5. Gamma-scout ONLINE Detector • Three workingmodes • Measurementuncertainty 5% • Readout of data in the real time • Data saving Picture from: https://www.radonshop.com/gamma-scout-online-geiger-counter-radiation-meter Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  6. geiger-müller TUBEINSIDE GAMMA-SCOUT DETECTOR 712 End Window-Alpha-Beta-Gamma DetectorPicture and specification from: https://www.sparkfun.com/datasheets/Components/General/LND-712-Geiger-Tube.pdf Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  7. Manufacturer’s software Real timereadout Saved data Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  8. GAMMA –SCOUTLabviewsoftware RUN PANEL Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  9. GAMMA –SCOUTLabviewsoftware SERVICE PANEL Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  10. GAMMA –SCOUTLabviewsoftware ENGINEERING PANEL Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  11. Gamma-scoutdetectorscalibration Compatibility test betweenthreedetectors Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  12. calibration – detectors placednext to eachother Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  13. Histograms – detectors placed next to each other AlicjaJakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  14. calibration – detectors placed one on top of the other Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  15. Histograms – detectors placed one on top of the other AlicjaJakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  16. compatibility in threeseperatelocations • Outside the RACK • Inside the RACK • On the RACK’scase AlicjaJakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  17. Results α+β+γ γ β+γ Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  18. histograms - α+β+γ Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  19. histograms - β+γ Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  20. histograms - γ Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  21. Self-builtgeiger-Müllercounter Data acquiredusingNI myDAQ Developer – BSc Nikita Dunin Self-built Geiger-Müller counter Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  22. geiger-müller TUBEIN the self-built DETECTOR STS-5 (СTC-5) Geiger tubePicture from https://www.pocketmagic.net/tube-sts-5-%D1%81tc-5-geiger-tube/ Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  23. NI myDAQDETAILS Picture and specificationfrom: https://slideplayer.com/slide/5931164/?fbclid=IwAR0SHzZJ2LJuTALgRqf2f2UeTc0kMyPBGr5yDAOrvxXDgg1yATTot1m3Wvg Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  24. Geiger-Müller countersignal Signalmeasuredwith PicoscopeUSB osciloscope Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  25. Geiger-Müller counterLabviewsoftware RUN PANEL Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  26. Geiger-Müller counterLabviewsoftware SERVICE PANEL Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  27. Geiger-Müller counterLabviewsoftware ENGINEERING PANEL Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  28. Conclusions • Gamma-Scoutdetectors and Geiger-Müller counterarebestused as real timesafety monitoring • Gamma-Scoutdetectors and Geiger-Müller counterareappropriate devices for monitoring radiationsafety onNICA-MPD-PALTFORM • Calibration test of Gamma-Scoutdetectors was successful • Lower number of impulsesdetectedinside the RACK for eachworkingmode • No significantdifferencebetweenresults on the RACK’scase and outside the RACK Alicja Jakubowska, Marta Robak, Anita Zagrobelna, warsawuniversity of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support

  29. THANK YOU FOR YOUR ATTENTION AlicjaJakubowska, Marta Robak, Anita Zagrobelna, warsaw university of technology, faculty of physics. Supervisor: Nikita Dunin and Engineering support