Lesson 4

Lesson 4. What are the units for measuring radon?. Radioactivity units Picocuries (pCi). Measure activity (radioactive decays/time) 1 picocurie (pCi) = 0.037 decays/second = 1 decay/27 seconds = 2.22 decays/minute. Radon units Picocuries/liter (pCi/L).

milton
Download Presentation

Lesson 4

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Lesson 4 What are the units for measuring radon?

  2. Radioactivity unitsPicocuries (pCi) Measure activity (radioactive decays/time) 1 picocurie (pCi) = 0.037 decays/second = 1 decay/27 seconds = 2.22 decays/minute

  3. Radon unitsPicocuries/liter (pCi/L) Measure activity (decays/minute) per volume(one liter of air) 1 pCi/L = 2.22 decays per minute per liter of air • EPA action level • = 4 pCi/L • = 8.88 decays/minute/liter

  4. Hypothetical daily exposure • Question • Assume that a client spent 10 hours/day in a room with a radon level of 4 pCi/L • How many decays/liter would the client be exposed to each day? • Answer • 5,328 decays/day/liter

  5. U.S. exposure to radiation

  6. Radioactivity units 1 becquerel (Bq) = 1 decay/second = 27 pCi 1 pCi = 0.037 decays/ second = 0.037 Bq Radon units 1 pCi/L = 37 Bq/m3 International System (SI) EPA action level = 4 pCi/L = 148 Bq/m3

  7. Measure alpha radiation emitted by short-lived RDPs Measuring radon decay products (RDPs) Polonium-218 Lead-214 Bismuth-214 Polonium-214

  8. 1 WL = Concentration of RDPs produced from one liter of air that contains 100 pCi/L of radon = Amount of short-lived RDPs that exists at a single moment if a container is kept at a constant 100 pCi/L Measuring RDPsWorking level (WL) EPA action level = 4 pCi/L = 0.02 WL

  9. EPA action level Summary 4 pCi/L = 148 Bq/m3 = 0.02 WL

  10. Questions?

  11. Some radon gas and RDPs escape as air flows out of home Remember RDP characteristics Solid particles Electrically charged React chemically Some RDPs attach to (plate out on) solid objects, such as Walls Floors Ceilings Furniture Plating out Lowers RDP concentration in air Plated out RDPs cannot be measured Only RDPs in air can be measured Factors that affect plating out also affect measurement of RDPs Factors that affect radon and RDP concentrations

  12. Factors that affect radon and RDP concentrations • Air circulation • Air moving within a room • Ventilation • Fresh air entering a room • Air filters • Particles suspended in the air • Dust • Smoke • Aerosols Air from open window Air from open door Some RDPs plated out

  13. Circulation = moving around air already in a room How would air circulation affect concentration of RDPs? May increase plating out, as RDP particles blow toward solid objects and attach to them As plating out increases, concentration of RDPs in the air decreases Air circulation Fans increase normal air circulation

  14. Ventilation = supply of fresh air How would ventilation affect concentration of RDPs? Ventilation likely to lower concentration of RDPs May also reduce radon concentration, as gas escapes from home Ventilation Open windows and doors increase ventilation

  15. How would air filters affect concentration of RDPs? Air filters may remove some RDPs, which Are particles Have electrical charge React chemically Air filter Example Furnace air filter • Air filters will not remove radon, which • Is a gas • Has no electrical charge • Does not readily react chemically

  16. Particles suspended in air • Examples • Dust • Smoke • Aerosols • How would particles affect concentration of RDPs? • RDPs are more likely to attach to particles • RDP concentration in air decreases

  17. ReviewFactors that may affect radon measurement • Air circulation • Ventilation • Air filters • Particles in the air

  18. Secular (eventual) equilibrium • In closed home, concentration of RDPs increases until secular equilibrium is reached • Means RDPs have same level of radioactivity as radon itself • Takes 3-4 hours • Measure home after it has reached secular equilibrium • At secular equilibrium, 1 WL = 100 pCi/L Radon decay products  Radon Radon

  19. Picocuries and becquerels; secular equilibrium. Radon decaying has made my brain cells go numb. But I do understand: breathing radon’s not healthy, So I’ll master these concepts, though they won’t make me wealthy. A home inspector’s lament and pledge Convert all these measurements? Curse that uranium! I’m working at levels that hurt my poor cranium. I’ll learn proper techniques, use the right protocol, To help prevent cancer: that’s the goal of my role.

  20. SummaryEPA action level 4 pCi/L = 148 Bq/m3 =0.02 WL 4 4 pCi/L = 148 Bq/m3 =0.02 WL See handout 4-1

  21. SummaryFactors affecting measurement • Air circulation • Ventilation • Air filters • Particles in the air Importance Factors affect conditions for testing a home

  22. Questions?

  23. Checkyour comprehension • See handout 4-2