90 likes | 227 Views
STATUS OF GLUING AT 04.02.2003. Problems to be studied Test protocol Thermal conductivity tests What next. GLUING THE Silicon Pixel Detectors. Main problems to be studied: thermal contact mechanical stability with UV glue. TEST PROTOCOL (I). Thermal adhesive tests.
E N D
STATUS OF GLUING AT 04.02.2003 Problems to be studied Test protocol Thermal conductivity tests What next
GLUING THE Silicon Pixel Detectors • Main problems to be studied: • thermal contact • mechanical stability with UV glue
TEST PROTOCOL (I) Thermal adhesive tests • a) thermal conductivity measurements • measurements for about 0.1 mm adhesive thickness • reduction of candidates to 2-3 • b) complete gluing tests • spreading the thermal adhesive on windowed kapton-glass samples fixed with UV glue above the cooling tube • glue spreading procedure tests • c) thermal contact reliability tests w.r.t. thermal cycles • test of thermal contact after many thermal cycles (about 5 – 50 °C ) with best candidates and best glue spreading procedure(s) • best candidate(s) selection and definition of gluing procedure • d) irradiation tests with best candidate(s) • thermal contact reliability test of best candidate(s) after irradiation • final selection of thermal adhesive
TEST PROTOCOL (II) Mechanical assembly with UV glue • a) UV gluing tests • - test the gluing strength with kapton-glass samples to be glued on CFSS • - tests of ungluing - tests of clip mounting UV glue quantity and curing time • b) irradiation tests • - test the UV gluing strength before and after irradiation
THERMAL CONDUCTIVITY TESTS (I) Let be: DISC 1 at T1 DISC 2 at T2 R dissipating a power W x the thickness of the glue A the area of the glue W = k A (T1 -T2) / x k = x W / (T1 - T2)A INSULATOR R ° D1 GLUE ° D2 PT100 FAN T from R(PT100) and tables (0.387 W / K)
THERMAL CONDUCTIVITY TESTS (II) PRELIMINARY RESULTS ( in brakets the ATLAS measurements ) expectedDT/W for 100 micron thickness assuming a chip with 4 x 12.5 = 50 mm2 thermal contact window
WHAT NEXT More electronics and mechanics for tests
WHAT NEXT: PLANNING • a) thermal conductivity measurements • - first measurements: done • - new setup for more precise measurements: ready • b) complete gluing tests • - production of kapton-glass samples with windows: to be realized • - XY movement for dispenser: to be fixed • c) thermal contact reliability tests w.r.t. thermal cycles • - mechanical setup and heaters defined, to be realized • d) UV gluing tests • - production of kapton-glass samples to be glued on CFSS: to be realized - clips: ready to be glued • e) irradiation tests with best candidate(s) • - setup for both thermal adhesive and UV glue: to be defined