1 / 22

K.U.Leuven LPC-Caen GSI Jyväskylä Univ. CERN-ISOLDE Krakow Jagell.Univ. Univ. Mainz

JRA-11 (TRAPSPEC) Improvements and developments of ion traps, spectrometers and detectors for low-energy nuclear physics experiments. K.U.Leuven LPC-Caen GSI Jyväskylä Univ. CERN-ISOLDE Krakow Jagell.Univ. Univ. Mainz RMKI-Budapest (ass.).

mimir
Download Presentation

K.U.Leuven LPC-Caen GSI Jyväskylä Univ. CERN-ISOLDE Krakow Jagell.Univ. Univ. Mainz

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. JRA-11 (TRAPSPEC)Improvements and developments of ion traps, spectrometers and detectors forlow-energy nuclear physics experiments K.U.Leuven LPC-Caen GSI Jyväskylä Univ. CERN-ISOLDE Krakow Jagell.Univ. Univ. Mainz RMKI-Budapest (ass.) EURONS PCC Meeting, Groningen, 11-12 December 2006

  2. Design and development of multi-purpose set-ups for precisiondecay spectroscopy in ion traps -particles and CE electrons: Si, MCP, wire chamber recoil ions: MCP detector, channeltron with CDEM Design and development of new trap configurations cryogenic Penning trap - superheavy elements - doubly and triply charged ions measurements on daughter isotopes of those originally trapped system to monitor phase space of trapped ion cloud EURONS PCC Meeting, Groningen, 11-12 December 2006

  3. electron & ion sources:- reference masses - study of systematic effects - off-line studies Performance enhancementof Penning-trap experiments by using dedicated new electron- and ion sources Retardation spectrometersfor recoil-ion spectroscopy for trap-assisted beta-neutrino correlation measurements -decay of exotic ions neutron -decay EURONS PCC Meeting, Groningen, 11-12 December 2006

  4. Task T-J11-2: Extended Paul trap set-up at SPIRAL-GANIL (LPC-Caen) sched. realiz. remark Chamber arrangement defined and fixed 12/05 04/08 Detectors defined and built 06/07 Ion cloud monitoring system ready 09/07 -recoil coincidences from decays in Paul trap 12/08 05/05 * • 2005, 2006: > 105 beta-ion coincidences • planning modified • all milestones will be realized in time EURONS PCC Meeting, Groningen, 11-12 December 2006

  5. LPC-Caen V-A theory 6He -recoil coincidences EURONS PCC Meeting, Groningen, 11-12 December 2006

  6. Task T-J11-3: Improved set-up for SHIPTRAP (SHIPTRAP-GSI) sched. realiz. remark Detector concept for in-trap decay ready 12/05 12/06 Test of cryogenic Penning trap system 12/06 DAQ and control system ready 06/07 First measurements 12/08 • some delay due to problems to find postdoc; • solved as of 01/07 • steady progress; milestones not at stake • 52 masses (17 new; accuracy 5 x 10-8) EURONS PCC Meeting, Groningen, 11-12 December 2006

  7. cryogenic trap test set-up SHIPTRAP-GSI EURONS PCC Meeting, Groningen, 11-12 December 2006

  8. Task T-J11-4: New detector and in-trap mass spectrometry with ISOLTRAP (CERN-ISOLDE) sched. realiz. remark Test set-up for CDEM 09/05 08/05 Software development 03/06 01/06 Test CDEM 12/06 05/06 * Mass spectrometry 12/08 08/06 * • all milestones realized • detection efficiency improved by factor ~3 • masses of A = 61-63 Fe nuclides (not produced at ISOLDE) EURONS PCC Meeting, Groningen, 11-12 December 2006

  9. ISOLTRAP/CERN-ISOLDE EURONS PCC Meeting, Groningen, 11-12 December 2006

  10. Task T-J11-5: In-trap spectrosc. & high-resol. mass spectrom. with JYFLTRAP(Jyväskylä Univ.)sched. realiz. remark Data acquisition operational 03/06 80% New trap available 12/07 06/06 * Results of multiply charged ions study 12/06 60% First measurements with upgraded system 12/07 09/06 * • 1st version of DAQ succesfully tested; being improved • tests with doubly-charged ions already performed • preparations for higher charge states in progress • 110 masses measured (accuracy up to 8 x 10-9) EURONS PCC Meeting, Groningen, 11-12 December 2006

  11. Jyväskylä Univ. in-trap CE spectrum new decay scheme EURONS PCC Meeting, Groningen, 11-12 December 2006

  12. Task T-J11-6: Electron tracking detector for beta-decay experiments (UJ-Krakow)sched. realiz. remark Concept of prototype available 12/05 12/05 Prototype operational 12/08 Readout and DAQ system available 12/08 • MWDC operating at P>0.3 bar • ~ linear response (tdrift vs. pos.) • spatial resolution ~1.5 mm • detector for LPC-Caen in progress EURONS PCC Meeting, Groningen, 11-12 December 2006

  13. 90Sr source MWDC detector UJ-Krakow scintillator PMT Test set-up EURONS PCC Meeting, Groningen, 11-12 December 2006

  14. Task T-J11-7: Detector development for WITCH (KU-Leuven) sched. realiz. remark Operation of MCP+pin diodes in high B-field 06/06 12/06 Normalization for recoil ion counting 12/05 12/07 Measurement of recoil ion energy spectrum 12/06 11/06 Detector set-up for beta-spectroscopy 12/08 • tests of MCP finished; Si pin diode ongoing • new concept for normalization (scintillator i.s.o. Si pin diodes) • first recoil ion spectrum measured (normalization via t1/2) • Geant-4 code for simulation of beta-spectra available EURONS PCC Meeting, Groningen, 11-12 December 2006

  15. KU-Leuven 39K MCP in magnetic field 39K 124In recoil spectrum 124In recoil spectrum EURONS PCC Meeting, Groningen, 11-12 December 2006

  16. Task T-J11-1 & 8: Neutron decay retardation spectrom. + simulations and calculations (U-Mainz; Budapest) sched. realiz. remark Design calculations finished 12/06 12/05 * Systematic effects understood 06/08 Data analysis under control 12/08 Spectrometer tested 12/05 10/05 Electron source (replaced by He source) 06/06 09/07 System tested and operational 03/08 First experiment12/08 EURONS PCC Meeting, Groningen, 11-12 December 2006

  17. U-Mainz; Budapest proton detector magnetic shielding EURONS PCC Meeting, Groningen, 11-12 December 2006

  18. JRA-11 (TRAPSPEC)Improvements and developments of ion traps, spectrometers and detectors forlow-energy nuclear physics experiments EURONS PCC Meeting, Groningen, 11-12 December 2006

  19. EURONS PCC Meeting, Groningen, 11-12 December 2006

  20. EURONS PCC Meeting, Groningen, 11-12 December 2006

  21. EURONS PCC Meeting, Groningen, 11-12 December 2006

  22. EURONS PCC Meeting, Groningen, 11-12 December 2006

More Related