210 likes | 328 Views
MPV 75/150 USER INTERFACE. AARON CARDENAS. WEB INTERFACE. Detailed system information System Summary Energy Reports Configuration Device Information Event History Real-time updates and control Remote configuration Easy remote upgrade/backup/restore No software installation required
E N D
MPV 75/150USER INTERFACE AARON CARDENAS
WEB INTERFACE • Detailed system information • System Summary • Energy Reports • Configuration • Device Information • Event History • Real-time updates and control • Remote configuration • Easy remote upgrade/backup/restore • No software installation required • Compatible with all major browsers and devices (iOS/Android/Tablets/Phones) • Built-in USER INTERFACE Web Interface
SUMMARY PAGE SCREENSHOT SUMMARY PAGE Web Interface
SUMMARY PAGE • Instantaneous Power with Percent Bar (Shows percentage of output compared to capacity) kW • Peak power for the current day (kW) • Energy produced for the current day (kWhr) • Graph behind the power readings highlighting power throughout the current day • Input Voltage and Current • Internal System Temperature (sensed from inside of the controller) • Grid Information • Voltage/Current/Frequency • Alarm Information • See manual for the complete list off alarms reported. • Operating Time • Commission Date • Cabinet Serial Number (matches label on the side of the cabinet) • Footer (Visible on all pages) • Alarm Status, Output Power, Operating Time, System Time, Model #, Serial # SUMMARY PAGE Web Interface
REPORTS PAGE SCREENSHOT REPORTS PAGE Web Interface
REPORTS PAGE • Day Graph • Table showing the energy (kWhr) produced each hour of the day • Line Graph shows the power thoughout the day. • May select different days of data to view. • Updated in real-time while viewing the page. • Month Graph • Table in calendar format shows energy produced each day of the month. • Bar Graph shows energy for each day of the month for easy comparison. • May select different months of data to view. • Year Graph • Table shows energy produced each month of the year. • Bar Graph shows energy for each month of the year for easy comparison. • May select different years of data to view. REPORTS PAGE Web Interface
DEVICES PAGE SCREENSHOT 1 DEVICES PAGE Web Interface
DEVICES PAGE SCREENSHOT 2 DEVICES PAGE Web Interface
DEVICES PAGE • Controller Info • Output Power, Status, Serial, FW Version • Inverter Info • Module output power, State (On, Off, Standby, Alarm), Status, Output Voltage/Current/Frequency, Input Voltage/Current, Temperature, Operating Time, Model, Serial, Vendor Code, FW versions. • Module background changes color depending on module state. • Distribution Info • Analog Inputs (Input Voltage/Current) • Discrete Inputs (Door, GFI, AC/DC Switches, Surge Protection Devices) • Relay Outputs (Input Contactors, GFI Control) • If the state graphic is filled in, that indicates that the particular input/output is active/connected • Inputs/Outputs can be labeled on the configuration page. DEVICES PAGE Web Interface
DEVICES PAGE (List View) SCREENSHOT DEVICES PAGE (List View) Web Interface
DEVICES PAGE (List View) • Tabular view of inverter parameters • ID – Shelf slot location • Output Power/Voltage/Current/Frequency • Temperatures • Sortable • Updated in real-time • Easy comparison of each inverter module DEVICES PAGE (List View) Web Interface
CONFIGURATION PAGE SCREENSHOT CONFIGURATION PAGE Web Interface
CONFIGURATION PAGE • System Configuration • Name, Description, Address, Commission Date, Date/Time, Temperature Units, GFI Control, Startup/Shutdown Control, LED Test. • Login button is at the top right of the page. • Notifications • Configure which e-mail address will receive alarms, event, and performance reports. • Note: This feature requires an e-mail server to be configured on the network page. • Inverters • Anti-Islanding configuration. • WARNING: The default values on this configuration screen are set to meet the requirements of UL 1741 and IEEE 1547. Contact technical support before changing any of these values. • Input/Output • Distribution input/output information. • Name, Polarity, Alarm, Feedback, Pulse Time. CONFIGURATION PAGE Web Interface
CONFIGURATION PAGE (continued) • Network • IP Configuration • Web Server Port • E-mail server • User Account • Web password • Administrator e-mail address • Local Access (Display) PIN number. • Backup/Restore • Upload: Controller FW, Inverter FW, Distribution FW, Display FW, Configuration • Conveniently upgrade system FW and configuration through one interface. • Backup Configuration/Data Logs • Reset to factory defaults CONFIGURATION PAGE (continued) Web Interface
EVENTS PAGE SCREENSHOT EVENTS PAGE Web Interface
EVENTS PAGE 1000 events stored Color coded Sortable Searchable *See Table 6-2 System Faults in the manual formore information on events that are stored. CONFIGURATION PAGE Web Interface
LOCAL INTERFACE • Main Screen • Output Power Gauge • Graphical representation of system state and configuration • Blank = Slot Empty • Solid = Standby • Dotted = On • Cross = Alarm • Day/Month/Year Energy Graphs • Alarms • Menu System • Detailed view of system parameters and device parameters • Alarm Reporting USER INTERFACE Local Display
MENU TREE • Main Screen • Date/Time, Input Voltage, Output Voltage/Current, Output Power Percent Bar • Day, Month, Year Bar Graph • Alarm Display • Cabinet Display with animated icons • Blank = Slot Empty • Solid = Standby • Dotted = On • Cross = Alarm • Main Menu • Alarms • Data • Array • Power, Current, Voltage, DC Switch Status, Contactor Positive/Negative Status • Cabinet • Number of inverters, Operating Hours, Remote Shutdown State USER INTERFACE Local Display
MENU TREE (continued) • Main Menu • Data • Inverter • Summary with power output • State, Status, Output Power, Energy Today, Capacity, Temperatures, Input Voltage/Current • Grid • Power, Energy Today, Voltage/Current (Phase ABC), Frequency, AC Switch Status • Clock • Date/Time, Day of Week • Network • IP Address Summary • Link status, State • Configuration • System • Location, Commission Date, Cabinet Serial, Model, Temperature Units, Hardware Revision, Mail Server/Port/Username, HTTP Port. USER INTERFACE Local Display
MENU TREE (continued) • Main Menu • Configuration • Display • FW Version Application/Bootloader • Inverter • Model, Serial, Vendor, FW Versions, Manufacturing Date • Clock • Date Format, Time Format, SNTP Server, Time Zone, Daylight Savings, DS Start/End, • Network • Type, IP, Gateway, Mask, DNS, MAC • Actions • Login (Default PIN: 1234) • Reset GFI • System Control (Start/Shutdown) • Change Display PIN • Display Settings • Beep, Inverter Colors, Language, Demo Mode USER INTERFACE Local Display
Future Development • Aggregated view of multiple cabinets from one interface • Weather station information display • 3rd party monitoring support • Improvements to the reports page • Graph annotations (mouse-over information) • New information (i.e. Temperature plots) • Custom comparisons (Compare different days, month, years) FUTURE DEVELOPMENT