An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CDC Readout - upgrade for Higher Luminosity - Y.Sakai (KEK) Review of Status/Plan (based on materials from S.Uno/M.Tanaka) 29-Oct-2002 TRG/DAQ WS @OCU

  2. Introduction CDC will work at L = 1035 → ?? x1035 with some mod/improvement (a la S.Uno) [ small cell type CDC with R>15cm] (Basic assumption) CDC readout Electronics to be designed to work up to CDC Hardware Limit (T0 Timing device is not included here)

  3. Requirement: CDC Basically same as present one • Tracking: Position Resolution (s~130um) • P-id: dE/dx (s~6% for MIPS) [ Trigger signals → not issue here (Y.Iwasaki)] Higher Lum. Machine : higher beam current High hit rate : 100~200KHz Smaller Cell (~7mm? ← 15~18mm) Fast Gas (80~100um/ns ← <40) Max. Drift time (Tmax) : ~100 ns ← 400ns

  4. CDC Hit Rate (present) • Hit rate of innermost part • >100KHz • chamber itself is working • Other layers: ~5KHz • → OK with higher • beam current • (>20 times higher BG) Radius = 15cm

  5. QT Deadtime & Efficiency Belle CDC Innermost 2 layers QT board replaced QT conv. Dead time ~700ns June-2002 Number of hits used in track Chamber Efficiency itself is OK with >100KHz hit rate ~200ns Oct-2002

  6. Fast Gas : CH4 80~100us/ns • dE/dx resolution : similar to He(50)/C2H6(50)

  7. CDC Readout Requirement Basically same as present one (except dead time) Normal ! Time Info. a la Tanaka-san sT~130um/vdrift → 1.3~1.6ns (v=80~100um/ns) ~0.5 ns LSB (1 ns maybe OK), Range ~ 2Tmax Charge Info. Dynamic range: >40MIPS sQ ~ sPED << ssig ~20% Linearity : < 0.5~1% Min. 10 bits (11~12 preferred) CDC hardware limit Dead Time/hit : CDC intrinsic = Tmax ~100ns < 500ns (10% @200KHz, ~Tmax preferred) Dead Time/trig. : < 3us (10%@30KHz) “Pipeline”

  8. Possible Choices Total number of channels : ~15K (← 8.4+1.8K) Preamp/Shaper : conventional one is OK thin & smaller : small cell size, less material Digitizers (I) FADC only - 100MHz, 8~9bit, data compression (II) “QTC” + TDC [TDC only] - Charge integ. QT: conversion dead time - TOT type: accuracy ok for dE/dx ? (III) TDC + slow ADC - TMC based TDC + 10~20MHz FADC (10bit)

  9. M.Tanaka (I) (II) (III) (A) (B)

  10. Component for T & dE/dx measurements(I) • 10bit 200MHz FADC • Performance : no problem • Power : problem ~1W/ch • 100MHz,8bit? Possible just do it. No R&D required • Alternative solution : Analog memory with deconvolution function ASIC  low power! R&D going on

  11. Component for T & dE/dx measurements(II) ASDQ on Flex circuit (K.Tauchi) Analog: preamplifier (Gain=1.5 mV/fC, 1.5ns rise) Shaping: Pole-zero cancel. (25 mV/fC, 5ns 0-paek, <2% undershoot) Discriminator: Baseline Restorer (fully differencial, AC cpoupling) Q-measurement: Time-over-Theshold, Width ~log(Q) Full range 120 fC Chip: 5.4x3.9mm2 PQFP, Rad-hard analog bipoler 8ch, 40mW, Noise ~2300e (10pF inp.cap)

  12. Component for T & dE/dx measurements(II) (continued) • ASDQ+TDC(TMC based) System is working • Enough performance for timing measurement • Need detailed study for dE/dx measurement Timing resolution<1nsec & (K.Tauchi)

  13. COPPER (DAQ platform) User I/O board FINESS

  14. Component for T & dE/dx measurements(III) • Conventional way • TDC  TMC core 24ch/FINESS 96ch/COPPER • ADC  10bit 20MHz HFADC 8ch/FINESS 32ch/COPPER FINESS development is on going (Trigger out to be considered) Dense implementation  ASIC(next. step)

  15. ASIC core development • HFADC core (for ADC FINESS ) • ~10bit • <20MHz • 0.5~4.5V • TMC core (for TDC FINESS) • 0.2~1ns • AMC core (for waveform sampler FINESS) • 64 samples • Analog BW < ?? TADC FINESS ASIC with (ADC+TDC) (goal)

  16. Component for COPPER I/F • L1 pipeline storage  T.Higuchi talk • One example This will be implemented in FINESS-proto for debug of COPPER

  17. Data Size (comments) (May-2001) Belle CDC: ~ 2KB + 50 * cdccur0 (~3KB=375 hits @L=3x1033 (cdccur0=20uA) → ~10KB @L=1035 (~1250 hits) (now it is smaller)

  18. Summary CDC upgrade for Higher Luminosity Readout Electronics: requirements can be satisfied with available technology R&D in progress, but still need more work We are looking for person/group to work on CDC upgrade for Electronics R&D and implement (work with Tanaka-san) and for Construction / installation

  19. Additionally… • Possibility of new TMC development project using 0.18um CMOS processModification for our purpose may be….. • Y. Arai san’s talk !!!Specification should be discussed asap

  20. Belle CDC (schematic)