1 / 21

General Guidelines for SPOP

PORTLAND OR LATA 672. General Guidelines for SPOP. SPOP is ordered and implemented on a per switch, per LATA basis Overflow is not permitted/allowed among/between different switches SPOP conversions must follow CenturyLink project guidelines

Download Presentation

General Guidelines for SPOP

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PORTLAND OR LATA 672 General Guidelines for SPOP • SPOP is ordered and implemented on a per switch, per LATA basis • Overflow is not permitted/allowed among/between different switches • SPOP conversions must follow CenturyLink project guidelines • Service Managers must obtain appropriate LATA Maps from the Wholesale SPOP website and email diagrams to customer to complete • Service Managers will control and validate LATA Maps (diagrams) to be used in conjunction with the Customer SPOP Checklist in the kick off (pre-provisioning meeting) • Completion of the SPOP Checklist and LATA Maps are required as part of the Joint Planning Process • Customer is responsible for sharing LATA Maps, Customer SPOP Checklist and all documentation related to SPOP with people within their own company associated with SPOP implementation (e.g., Network, Order Writing, Provisioning, etc.,) • For WSPs, the Service Manager will assist the customer for localities where 2 way trunking is not available due to cell pack feature unavailability. • SLRN may be in affect on your local trunk groups - Conversion to SPOP may result in traffic pattern changes • You may not need a trunk group to the local tandem: • If you are only serving customers in this Local Tandem Area using a LRN that is outside of the Local Calling Area and; • You do not have a full NPA-NXX and; • You exchange less than one DS1 or less than 512 BHCCS worth of traffic to the local tandem and you are not using ARLRN but normal (default) routing • You may still want a trunk group to the local tandem for your originating traffic to CenturyLink and other A-Record Holder Providers in the Local Calling Area Rev. 02/17/2012

  2. NPA-NXXs ASTROR64C9T ACCESS TANDEM LERG SWITCH CLLI POI / ACTL CLLI ACTUAL SWITCH CLLI & POINT CODE DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. PORTLAND OR LATA 672 CUSTOMER NAME and ACNA * Locality covered by local tandem – submit diagram for local tandem, also. REV. 02/28/08

  3. DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. PORTLAND OR LATA 672 INSTRUCTIONS • Use previous slide as a template. Copy all and paste to new document • In top left box enter the full NPA-NXXs* assigned to the switch and in LATA 672 (full NPA-NXXs should go in CNPANXX fields on Translations Questionnaire.) • In center left boxes enter LERG switch CLLI (this is always the PSL on the Access Service Request Form of the ASR) and POI/ACTL CLLI (this is the ACTL on the Access Service Request Form). If POI/ACTL CLLI is owned by another OCN, LOA must be provided. • In lower left hexagon enter actual switch CLLI from SHA screen in LERG and point code (actual switch CLLI is always the CSL and the point code is entered in the CSPC field on the TRUNKING form of the ASR). LERG switch CLLI and actual switch CLLI may be the same if the actual switch is in the same LATA and then PSL and CSL would be the same CLLI. • EITHER enter a single line from POI/ACTL CLLI box to each access tandem circle and label “2W SPOP COMBINED” and include quantity of trunks requested OR enter 2 lines from POI/ACTL CLLI box to each access tandem circle and label top line “2W SPOP IXC” and bottom line “2W SPOP Local/Intra” and include quantity of trunks requested. • Indicate the CenturyLink localities where you will be conducting business (pooling, porting, etc) by changing the color to red. * Full NPA-NXXs – also known as “Code Holder”, “LERG Assignee”, or “A Record Holder” Rev. 02/17/2012

  4. PORTLAND OR LATA 672 NPA-NXXs PNTNOR56C9T ACCESS TANDEM LERG SWITCH CLLI POI / ACTL CLLI ACTUAL SWITCH CLLI & POINT CODE DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. CUSTOMER NAME and ACNA REV. 02/28/08

  5. DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. PORTLAND OR LATA 672 INSTRUCTIONS • Use previous slide as a template. Copy all and paste to new document • In top left box enter the full NPA-NXXs* assigned to the switch and in LATA 672 (full NPA-NXXs should go in CNPANXX fields on Translations Questionnaire.) • In center left boxes enter LERG switch CLLI (this is always the PSL on the Access Service Request Form of the ASR) and POI/ACTL CLLI (this is the ACTL on the Access Service Request Form). If POI/ACTL CLLI is owned by another OCN, LOA must be provided. • In lower left hexagon enter actual switch CLLI from SHA screen in LERG and point code (actual switch CLLI is always the CSL and the point code is entered in the CSPC field on the TRUNKING form of the ASR). LERG switch CLLI and actual switch CLLI may be the same if the actual switch is in the same LATA and then PSL and CSL would be the same CLLI. • EITHER enter a single line from POI/ACTL CLLI box to each access tandem circle and label “2W SPOP COMBINED” and include quantity of trunks requested OR enter 2 lines from POI/ACTL CLLI box to each access tandem circle and label top line “2W SPOP IXC” and bottom line “2W SPOP Local/Intra” and include quantity of trunks requested. • Indicate the CenturyLink localities where you will be conducting business (pooling, porting, etc) by changing the color to red. * Full NPA-NXXs – also known as “Code Holder”, “LERG Assignee”, or “A Record Holder” Rev. 02/17/2012

  6. NPA-NXXs PTLDOR13C9T ACCESS TANDEM LERG SWITCH CLLI POI / ACTL CLLI ACTUAL SWITCH CLLI & POINT CODE DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. PORTLAND OR LATA 672 CUSTOMER NAME and ACNA * Locality covered by local tandem – submit diagram for local tandem, also. REV. 02/28/08

  7. DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. PORTLAND OR LATA 672 INSTRUCTIONS • Use previous slide as a template. Copy all and paste to new document • In top left box enter the full NPA-NXXs* assigned to the switch and in LATA 672 (full NPA-NXXs should go in CNPANXX fields on Translations Questionnaire.) • In center left boxes enter LERG switch CLLI (this is always the PSL on the Access Service Request Form of the ASR) and POI/ACTL CLLI (this is the ACTL on the Access Service Request Form). If POI/ACTL CLLI is owned by another OCN, LOA must be provided. • In lower left hexagon enter actual switch CLLI from SHA screen in LERG and point code (actual switch CLLI is always the CSL and the point code is entered in the CSPC field on the TRUNKING form of the ASR). LERG switch CLLI and actual switch CLLI may be the same if the actual switch is in the same LATA and then PSL and CSL would be the same CLLI. • EITHER enter a single line from POI/ACTL CLLI box to each access tandem circle and label “2W SPOP COMBINED” and include quantity of trunks requested OR enter 2 lines from POI/ACTL CLLI box to each access tandem circle and label top line “2W SPOP IXC” and bottom line “2W SPOP Local/Intra” and include quantity of trunks requested. • Indicate the CenturyLink localities where you will be conducting business (pooling, porting, etc) by changing the color to red. * Full NPA-NXXs – also known as “Code Holder”, “LERG Assignee”, or “A Record Holder” Rev. 02/17/2012

  8. NPA-NXXs RDMDOR01C9T ACCESS TANDEM LERG SWITCH CLLI POI / ACTL CLLI ACTUAL SWITCH CLLI & POINT CODE DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. PORTLAND OR LATA 672 CUSTOMER NAME and ACNA * Locality covered by local tandem – submit diagram for local tandem, also. REV. 02/28/08

  9. DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. PORTLAND OR LATA 672 INSTRUCTIONS • Use previous slide as a template. Copy all and paste to new document • In top left box enter the full NPA-NXXs* assigned to the switch and in LATA 672 (full NPA-NXXs should go in CNPANXX fields on Translations Questionnaire.) • In center left boxes enter LERG switch CLLI (this is always the PSL on the Access Service Request Form of the ASR) and POI/ACTL CLLI (this is the ACTL on the Access Service Request Form). If POI/ACTL CLLI is owned by another OCN, LOA must be provided. • In lower left hexagon enter actual switch CLLI from SHA screen in LERG and point code (actual switch CLLI is always the CSL and the point code is entered in the CSPC field on the TRUNKING form of the ASR). LERG switch CLLI and actual switch CLLI may be the same if the actual switch is in the same LATA and then PSL and CSL would be the same CLLI. • EITHER enter a single line from POI/ACTL CLLI box to each access tandem circle and label “2W SPOP COMBINED” and include quantity of trunks requested OR enter 2 lines from POI/ACTL CLLI box to each access tandem circle and label top line “2W SPOP IXC” and bottom line “2W SPOP Local/Intra” and include quantity of trunks requested. • Indicate the CenturyLink localities where you will be conducting business (pooling, porting, etc) by changing the color to red. * Full NPA-NXXs – also known as “Code Holder”, “LERG Assignee”, or “A Record Holder” Rev. 02/17/2012

  10. PORTLAND OR LATA 672 NPA-NXXs ASTROR6450T LOCAL TANDEM LERG SWITCH CLLI ACTUAL SWITCH CLLI & POINT CODE DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. CUSTOMER NAME and ACNA If Existing POI/ACTL CLLI – Identify the POI/ACTL CLLI If Need New POI/ACTL CLLI – Identify City Name for the POI/ACTL CLLI REV. 7/21/09

  11. DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame PORTLAND OR LATA 672 INSTRUCTIONS WARNING – SLRN may be in affect on your local trunk groups - Conversion to SPOP may result in traffic pattern changes • Use previous slide as a template. Copy all and paste to new document • In top left box enter the full NPA-NXXs* assigned to the switch and in the ASTORIA, OR LOCAL CALLING AREA (on ASR, full NPA-NXXs should go in CNPANXX fields on Translations Questionnaire). If no full NPA-NXXs, MAY REQUEST ARLRN. SEE ARLRN PCAT FOR MORE INFORMATION. http://www.centurylink.com/wholesale/clecs/slrn.html • In center left boxes enter LERG switch CLLI (this is always the PSL on the ICASR page of the ASR) and POI/ACTL CLLI (this is the ACTL on the ICASR page). If POI/ACTL CLLI is owned by another OCN, LOA must be provided. • In lower left hexagon enter actual switch CLLI from SHA screen in LERG and point code (actual switch CLLI is always the CSL and the point code is entered in the CSPC field on the TRUNKING form of the ASR). LERG switch CLLI and actual switch CLLI may be the same if the actual switch is in the same LATA and then PSL and CSL would be the same CLLI. • Enter a single line from POI/ACTL CLLI box to each local tandem circle and label “2W SPOP LOCAL” and include quantity of trunks requested. • Indicate the CenturyLink localities where you will be conducting business by changing the color to red. • * Full NPA-NXXs – also known as “Code Holder”, “LERG Assignee”, or “A Record Holder” Rev. 02/17/2012

  12. PORTLAND OR LATA 672 NPA-NXXs BENDOR2451T LOCAL TANDEM LERG SWITCH CLLI ACTUAL SWITCH CLLI & POINT CODE DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. CUSTOMER NAME and ACNA If Existing POI/ACTL CLLI – Identify the POI/ACTL CLLI If Need New POI/ACTL CLLI – Identify City Name for the POI/ACTL CLLI REV. 7/21/09

  13. DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame INSTRUCTIONS PORTLAND OR LATA 672 WARNING – SLRN may be in affect on your local trunk groups - Conversion to SPOP may result in traffic pattern changes • Use previous slide as a template. Copy all and paste to new document • In top left box enter the full NPA-NXXs* assigned to the switch and in the BEND, OR LOCAL CALLING AREA (on ASR, full NPA-NXXs should go in CNPANXX fields on Translations Questionnaire). If no full NPA-NXXs, MAY REQUEST ARLRN. SEE ARLRN PCAT FOR MORE INFORMATION. http://www.centurylink.com/wholesale/clecs/slrn.html • In center left boxes enter LERG switch CLLI (this is always the PSL on the ICASR page of the ASR) and POI/ACTL CLLI (this is the ACTL on the ICASR page). If POI/ACTL CLLI is owned by another OCN, LOA must be provided. • In lower left hexagon enter actual switch CLLI from SHA screen in LERG and point code (actual switch CLLI is always the CSL and the point code is entered in the CSPC field on the TRUNKING form of the ASR). LERG switch CLLI and actual switch CLLI may be the same if the actual switch is in the same LATA and then PSL and CSL would be the same CLLI. • Enter a single line from POI/ACTL CLLI box to each local tandem circle and label “2W SPOP LOCAL” and include quantity of trunks requested. • Indicate the CenturyLink localities where you will be conducting business by changing the color to red. • * Full NPA-NXXs – also known as “Code Holder”, “LERG Assignee”, or “A Record Holder” Rev. 02/17/2012

  14. PORTLAND OR LATA 672 NPA-NXXs LGVWWA0251T LOCAL TANDEM LERG SWITCH CLLI ACTUAL SWITCH CLLI & POINT CODE DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. CUSTOMER NAME and ACNA If Existing POI/ACTL CLLI – Identify the POI/ACTL CLLI If Need New POI/ACTL CLLI – Identify City Name for the POI/ACTL CLLI REV. 7/21/09

  15. DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame INSTRUCTIONS PORTLAND OR LATA 672 WARNING – SLRN may be in affect on your local trunk groups - Conversion to SPOP may result in traffic pattern changes • Use previous slide as a template. Copy all and paste to new document • In top left box enter the full NPA-NXXs* assigned to the switch and in the LONGVIEW, WA LOCAL CALLING AREA (on ASR, full NPA-NXXs should go in CNPANXX fields on Translations Questionnaire). If no full NPA-NXXs, MAY REQUEST ARLRN. SEE ARLRN PCAT FOR MORE INFORMATION. http://www.centurylink.com/wholesale/clecs/slrn.html • In center left boxes enter LERG switch CLLI (this is always the PSL on the ICASR page of the ASR) and POI/ACTL CLLI (this is the ACTL on the ICASR page). If POI/ACTL CLLI is owned by another OCN, LOA must be provided. • In lower left hexagon enter actual switch CLLI from SHA screen in LERG and point code (actual switch CLLI is always the CSL and the point code is entered in the CSPC field on the TRUNKING form of the ASR). LERG switch CLLI and actual switch CLLI may be the same if the actual switch is in the same LATA and then PSL and CSL would be the same CLLI. • Enter a single line from POI/ACTL CLLI box to each local tandem circle and label “2W SPOP LOCAL” and include quantity of trunks requested. • Indicate the CenturyLink localities where you will be conducting business by changing the color to red. • * Full NPA-NXXs – also known as “Code Holder”, “LERG Assignee”, or “A Record Holder” Rev. 02/17/2012

  16. PORTLAND OR LATA 672 NPA-NXXs PTLDOR1350T LOCAL TANDEM LERG SWITCH CLLI ACTUAL SWITCH CLLI & POINT CODE DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. CUSTOMER NAME and ACNA If Existing POI/ACTL CLLI – Identify the POI/ACTL CLLI If Need New POI/ACTL CLLI – Identify City Name for the POI/ACTL CLLI REV. 7/21/09

  17. DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame INSTRUCTIONS PORTLAND OR LATA 672 WARNING – SLRN may be in affect on your local trunk groups - Conversion to SPOP may result in traffic pattern changes • Use previous slide as a template. Copy all and paste to new document • In top left box enter the full NPA-NXXs* assigned to the switch and in the PORTLAND, OR LOCAL CALLING AREA (on ASR, full NPA-NXXs should go in CNPANXX fields on Translations Questionnaire). If no full NPA-NXXs, MAY REQUEST ARLRN. SEE ARLRN PCAT FOR MORE INFORMATION. http://www.centurylink.com/wholesale/clecs/slrn.html • In center left boxes enter LERG switch CLLI (this is always the PSL on the ICASR page of the ASR) and POI/ACTL CLLI (this is the ACTL on the ICASR page). If POI/ACTL CLLI is owned by another OCN, LOA must be provided. • In lower left hexagon enter actual switch CLLI from SHA screen in LERG and point code (actual switch CLLI is always the CSL and the point code is entered in the CSPC field on the TRUNKING form of the ASR). LERG switch CLLI and actual switch CLLI may be the same if the actual switch is in the same LATA and then PSL and CSL would be the same CLLI. • Enter a single line from POI/ACTL CLLI box to each local tandem circle and label “2W SPOP LOCAL” and include quantity of trunks requested. • Indicate the CenturyLink localities where you will be conducting business by changing the color to red. • * Full NPA-NXXs – also known as “Code Holder”, “LERG Assignee”, or “A Record Holder” Rev. 02/17/2012

  18. PORTLAND OR LATA 672 NPA-NXXs SALMOR5850T LOCAL TANDEM LERG SWITCH CLLI ACTUAL SWITCH CLLI & POINT CODE DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. CUSTOMER NAME and ACNA If Existing POI/ACTL CLLI – Identify the POI/ACTL CLLI If Need New POI/ACTL CLLI – Identify City Name for the POI/ACTL CLLI REV. 7/21/09

  19. DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame INSTRUCTIONS PORTLAND OR LATA 672 WARNING – SLRN may be in affect on your local trunk groups - Conversion to SPOP may result in traffic pattern changes • Use previous slide as a template. Copy all and paste to new document • In top left box enter the full NPA-NXXs* assigned to the switch and in the SALEM, OR LOCAL CALLING AREA (on ASR, full NPA-NXXs should go in CNPANXX fields on Translations Questionnaire). If no full NPA-NXXs, MAY REQUEST ARLRN. SEE ARLRN PCAT FOR MORE INFORMATION. http://www.centurylink.com/wholesale/clecs/slrn.html • In center left boxes enter LERG switch CLLI (this is always the PSL on the ICASR page of the ASR) and POI/ACTL CLLI (this is the ACTL on the ICASR page). If POI/ACTL CLLI is owned by another OCN, LOA must be provided. • In lower left hexagon enter actual switch CLLI from SHA screen in LERG and point code (actual switch CLLI is always the CSL and the point code is entered in the CSPC field on the TRUNKING form of the ASR). LERG switch CLLI and actual switch CLLI may be the same if the actual switch is in the same LATA and then PSL and CSL would be the same CLLI. • Enter a single line from POI/ACTL CLLI box to each local tandem circle and label “2W SPOP LOCAL” and include quantity of trunks requested. • Indicate the CenturyLink localities where you will be conducting business by changing the color to red. • * Full NPA-NXXs – also known as “Code Holder”, “LERG Assignee”, or “A Record Holder” Rev. 02/17/2012

  20. PORTLAND OR LATA 672 NPA-NXXs VANCWANO50T LOCAL TANDEM LERG SWITCH CLLI ACTUAL SWITCH CLLI & POINT CODE DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame. CUSTOMER NAME and ACNA If Existing POI/ACTL CLLI – Identify the POI/ACTL CLLI If Need New POI/ACTL CLLI – Identify City Name for the POI/ACTL CLLI REV. 7/21/09

  21. DISCLAIMER: all routing should follow LERG routing guidelines. SPOP diagrams are valid for 6 months from date of approval; implementation must occur within that time frame INSTRUCTIONS PORTLAND OR LATA 672 WARNING – SLRN may be in affect on your local trunk groups - Conversion to SPOP may result in traffic pattern changes • Use previous slide as a template. Copy all and paste to new document • In top left box enter the full NPA-NXXs* assigned to the switch and in the VANCOUVER, WA LOCAL CALLING AREA (on ASR, full NPA-NXXs should go in CNPANXX fields on Translations Questionnaire). If no full NPA-NXXs, MAY REQUEST ARLRN. SEE ARLRN PCAT FOR MORE INFORMATION. http://www.centurylink.com/wholesale/clecs/slrn.html • In center left boxes enter LERG switch CLLI (this is always the PSL on the ICASR page of the ASR) and POI/ACTL CLLI (this is the ACTL on the ICASR page). If POI/ACTL CLLI is owned by another OCN, LOA must be provided. • In lower left hexagon enter actual switch CLLI from SHA screen in LERG and point code (actual switch CLLI is always the CSL and the point code is entered in the CSPC field on the TRUNKING form of the ASR). LERG switch CLLI and actual switch CLLI may be the same if the actual switch is in the same LATA and then PSL and CSL would be the same CLLI. • Enter a single line from POI/ACTL CLLI box to each local tandem circle and label “2W SPOP LOCAL” and include quantity of trunks requested. • Indicate the CenturyLink localities where you will be conducting business by changing the color to red. • * Full NPA-NXXs – also known as “Code Holder”, “LERG Assignee”, or “A Record Holder” Rev. 02/17/2012

More Related