1 / 4

The Fixed-Array Hodoscope of the Hall-D Tagger

The Fixed-Array Hodoscope of the Hall-D Tagger. Updates by D. Sober (CUA) GlueX Collaboration Meeting, May 2009. The Hall-D Tagging Hodoscopes. Beam energy E 0 =12 GeV coherent peak at 6-11 GeV (typically 9.0 GeV) microscope tags 800 MeV window near coherent peak

Download Presentation

The Fixed-Array Hodoscope of the Hall-D Tagger

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Fixed-Array Hodoscope of the Hall-D Tagger Updates by D. Sober (CUA) GlueX Collaboration Meeting, May 2009

  2. The Hall-D Tagging Hodoscopes • Beam energy E0=12 GeV • coherent peak at 6-11 GeV (typically 9.0 GeV) • microscope tags 800 MeV window near coherent peak • fixed hodoscope (tags 3.0-11.7 GeV) • located on focal plane (in front of microscope) Requirements for fixed hodoscope: • crystal alignment→ special runs at reduced rate • tagging of high-E photons (above coherent peak) → at full production rate • monitoring of photon spectrum (current integration for Eγ<9 GeV) → at full production rate • alignment of microscope • tagging of large range and near-endpoint energies (extension for experiments other than GlueX)

  3. Fixed array hodoscope: Counter 90: Eγ=9.00-9.03 GeV • 190 counters of 30 MeV bites (0.25% E0 steps) • sampling: 3.0 – 9.0 GeV (100 counters) • full coverage: 9.0 – 11.7 GeV only these 90 counters operated in tagging mode during production runs Scintillators: BC-418 (rise time 0.5 ns, decay time 1.4 ns) Counter 34: Eγ=10.68-10.71 GeV Background rates < 1% (geant simulation)

  4. Readout standard Hall-D readout electronics: LE discr., F1-TDC, fADC, Scaler (fADC for calibration and current integration of counters at Eγ<9 GeV during production runs) Original setup: PMT + VD: XP2900 (or XP3110): ~2ns rise time, ~20ns transit time, gain 8*106 (or 2*106) • New setup: • Hamamatsu R4124 (1/2” PMT): • rise time 1.1ns, transit time 12ns • 2 PMTs & bases just arrived at CUA: • performance test with fast LED pulser over next days • Modify design drawings by end of May if tests successful • resolution and rate tests during next photon run in Hall B • (spring 2010) • Estimated timing resolution: • ~8000 γproduced in 5mm scint. → ~400 p.e. → better than 200 ps μ-metal shield (annealed iron 4.5 mm thick) Cage for single PMT (easy access, adjustments ±2 mm)

More Related