1 / 24

Welcome to KPB INTRA s.r.o.

Welcome to KPB INTRA s.r.o. KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com. Main milestones of KPB INTRA development. 1995. Company foundation – Knápek+Pospíšil+Bureš = KPB. 1996.

molimo
Download Presentation

Welcome to KPB INTRA s.r.o.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Welcome to KPB INTRA s.r.o. KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  2. Main milestones of KPB INTRA development 1995 Company foundation – Knápek+Pospíšil+Bureš = KPB 1996 Type tests of the CTS 12 and CTS 25 transformers 1997 Type tests of the VTS 12 and VTS 25 transformers 1998 2001 Type test of the first outdoor transformer VTDO 25 Purchase of production premises of former STS company in Bučovice Start of cooperation with Dutch company MEKUFA 2001 2006 Building of a new hall intended for transformer casting ISO 9001:2000 certification ISO 1400:2000 certification 2007 2008 Building of our self calibration facility KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  3. KPB Intra s.r.o. KPB Intra Polska 50% Kovatom s.r.o. 50% MEKUFA CZ s.r.o. 30% AMPER INTRA 50% Our other activities KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  4. Reference customer ABB AG - Division Energietechnik DE – Ratingen AMPER UA - Kyjev APPLIC CZ - Liberec AREVA CZ - Praha ČEZ CZ - Praha E-ON CZ - České Budějovice, SK – Bratislava SIEMENS CZ – Praha, AU – Linz MOELLER CZ – Praha, SK - Bratislava SCHNEIDER ELECTRIC CZ – Písek, SK – Bratislava, PL – Warsava PRE CZ - Praha EVN – Bulharsko VSE SK – Košice ZPUE PL – Wloszczowa KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  5. Prograss of the turnover in CZK KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  6. Progress of the number of employees KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  7. Production range of KPB INTRA Current measuring transformers • Outdoor type • Indoor type Voltage measuring transformers • Outdoor type • Indoor type Special transformers and sensors KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  8. Measuring current transformers – outdoor type CTSO 38 Supporting transformer • Insulation voltage: 38.5 kV • Testing voltage: 80 kV • Rated primary current: 5-1250 A • Rated secondary current: 5(1) A • Output: 5-60 VA • Accuracy classes: 0.2, 0.5, 0.2S, 0.5S, 1, 5P, 10P • Surface path length: 1257 mm • Weight: 62 kg • Approval No.: TCM 212/98-2963 CTSO 38 KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  9. Measuring current transformers – indoor type CTS 12 Supporting transformer • Insulation voltage: 15 kV • Testing voltage: 28 kV • Rated primary current: 5-3200 A • Rated secondary current: 5(1) A • Output: 5-60 VA • Accuracy classes: 0.2, 0.5, 0.2S, 0.5S, 1, 3, 5P, 10P • Surface path length: 1257 mm • Weight: 22 (25) kg • Approval No.: TCM 212/96-2415 Two modifications: S and L KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  10. Measuring current transformers – indoor type CTSO 25, CTS 25 Sch, CTS 25X, CTS 25X Sch Supporting transformers • Insulation voltage: 25 kV • Testing voltage: 50 kV • Rated primary current: • CTS 25: 5-3200 A • CTS 25X, CTS 25X Sch: 5-600 A • CTS 25 Sch: 5-1250 A • Rated secondary current: 5(1) A • Output: 5-60 VA • Accuracy classes: 0.2, 0.5, 0.2S, 0.5S, 1, 5P, 10P • Weight: • CTS 25: 28 kg • CTS 25X, CTS 25X Sch: 18 kg • CTS 25 Sch: 24 kg • Approval No.: TCM 212/96-2416, TCM 212/05-4311 • TCM 212/05-4312 CTS 25 CTS 25 Sch CTS 25X Sch CTS 25X KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  11. Measuring current transformers – indoor type CTS 38, CTS 38X, CTS 38X Sch Supporting transformers • Insulation voltage: 40.5 kV • Testing voltage: 95 kV • Rated primary current: • CTS 38: 5-1500 A • CTS 38X, CTS 38X Sch: 5-600 A • Rated secondary current: 5(1) A • Output: 5-60 VA • Accuracy classes: 0.2, 0.5, 0.2S, 0.5S, 1, 3, 5P, 10P • Weight: • CTS 38: 40 kg • CTS 38X, CTS 38X Sch: 28 kg • Approval No.: TCM 212/98-2786, TCM 212/06-4347 • TCM 212/06-4346 CTS 38 CTS 38X CTS 38X Sch KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  12. Measuring current transformers – indoor type CTB 25 – Bushing-type transformer CTT 25 – Pass-type transformer • Insulation voltage: 25 kV • Testing voltage: 50 kV • Rated primary current: 5-1500 A • Rated secondary current: 5(1) A • Output: 5-60 VA • Accuracy classes: 0.2, 0.5, 0.2S, 0.5S, 1, 3, 5P, 10P • Weight: • CTB 25: 22 kg • CTT 25: 17 kg • Approval No.: ТСМ 212/00-3343 ТСМ 212/00-3342 CTB 25 CTT 25 KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  13. Measuring voltage transformers – outdoor type VTO 38 – earthed voltage transformer • Insulation voltage: 38.5 kV • Testing voltage: 80 kV • Rated primary voltage: 3000/√3–35000/√3 V • Rated secondary voltage: 100/√3,110/√3, 120/√3 V • Rated auxiliary voltage: 100/3, 110/3, 120/3 V • Output: 10, 30, 50, 75, 100, 150 VA • Accuracy classes: 0.2, 0.5, 1, 3P, 6P • Weight: 46 kg • Approval No.: TCM 212/05-4239 VTO 38 KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  14. Measuring voltage transformers – outdoor type VPT 25 – unearthed voltage transformer VPT 38 – earthed voltage transformer VPT 25 • Insulation voltage: 25 kV (38.5) kV • Testing voltage: 50 kV (80) kV • Rated primary voltage: 3000-22000 (35000) V • Rated secondary voltage: 100, 110, 120 V • Output: 500 VA • Accuracy classes: 0.2, 0.5, 1 • Weight: • VPT 25: 49 kg • VPT 38: 62 kg • Approval No.: ТСМ 212/02-3636, ТСМ 212/02-3749 VPT 38 KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  15. Measuring voltage transformers – indoor type VTS 12 – earthed voltage transformer VTS 25, 25 Sch – earthed voltage transformer VTS 12 • Insulation voltage: 17.5 kV (25) kV • Testing voltage: 38 kV (50) kV • Rated primary voltage: 3000/√3–15000/√3 V 3000/√3–22000/√3 V • Rated secondary voltage: 100/√3,110/√3, 120/√3 V • Output: 10,30,50,75,100,150 VA • Limit output: 400 (500) VA • Accuracy classes: 0.2, 0.5, 1, 3P, 6P • Weight: • VTS 12: 21 kg • VTS 25: 29 kg • Approval No.: TCM 212/98-2908 TCM 212/97-2656 VTS 25 Sch VTS 25 KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  16. Measuring voltage transformers – indoor type VTS 38 – earthed voltage transformer • Insulation voltage: 38.5 kV (40.5) kV • Testing voltage: 80 kV (95) kV • Rated primary voltage: 3000/√3–35000/√3 V • Rated secondary voltage: 100/√3,110/√3, 120/√3 V • Output: 10,30,50,75,100,150 VA • Limit output: 500 VA • Accuracy classes: 0.2, 0.5, 1, 3P, 6P • Weight: 33 kg • Approval No.: TCM 212/98-2963 VTS 38 KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  17. Voltage measuring transformers – indoor type VTD 12 – unearthed voltage transformer VTD 25 – unearthed voltage transformer VTD 12 • Insulation voltage: 17.5 kV (25) kV • Testing voltage: 38 kV (50) kV • Rated primary voltage: 3000–15000 V 3000–22000 V • Rated secondary voltage: 100,110, 120 V • Output: 400 (500) VA • Accuracy classes: 0.2, 0.5, 1, 3P, 6P • Weight: • VTS 12: 22 kg • VTS 25: 29 kg • Approval No.: TCM 212/98-2907 TCM 212/98-2978 VTD 25 KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  18. Special transformers CTR 1 – totalling current transformer • Maximum mains voltage: 0.72 kV • Insulation voltage50Hz 1min: 3 kV • Rated conversion: 10/>0.08 A • Rated frequency: 50 Hz • Output: 0.1 VA (15Ω) • Weight: 15 kg CTR 1 KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  19. Special transformers VTDOR 38 – voltage transformer VTDOR 38 • Rated primary voltage: 5150 to 6300 V • Rated secondary voltage: 230 V • Rated frequency: 50-75 Hz • Short-circuit voltage: 4.5% • Output: 0 – 1.2 kVA • Limit output: 1.2 kVA • Weight: 51 kg The transformer was specifically developed for Czech Railways applications. KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  20. Special transformers VPT 100 – voltage transformer VPT 100 • Rated primary voltage: 230 (380) V • Rated secondary voltage: 100 kV • Rated frequency: 50 Hz • Output: 3 kVA • Limit output: 7 kVA • Weight: 125 kg KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  21. Special transformers VPPT 38.2– power voltage transformer VPPT 38.2 • Rated primary voltage:3000 - 35000 V • Rated secondary voltage: 100, 110, 120, 230 V • Rated frequency: 50 Hz • Limit output:2500 VA • Weight:85 kg Voltage instrument transformers VPPT 38.2 are single-phase transformers. They are designed for the use in the high voltage systems. They are designed for measuring and protection of high voltage distributing equipment for outdoor design. They are suitable for supplying of drives of remote-controlled section switches. KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  22. Current sensor CSO 25 – current sensor CSO 25 • Insulation voltage: 25 kV • Rated primary current: 100-400 A • Short-circuit class Ith/Idyn:16/40 kA • Rated secondary current: 1.5 A • Rated frequency: 50 Hz • Burden: 2 VA • Accuracy class: 3% • Instrument security factor: >5 KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  23. Current sensor VSO 25 – capacitor voltage sensor • Insulation voltage: 25 kV • Rated primary voltage: 22/√3 kV • Rated secondary voltage:0–230 V (130 V ±15% for burden 1MΩ) • Rated frequency: 50 Hz • Sensing capacity C1: 50 to 60pF • Capacity of loaded outlet per meter length C2: 280pF/m VSO 25 KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com

  24. Thank you for your attention Potential questions will be answered by: • Ing. Robert Knápek – Executive: +420 603 481 128 knapek@kpbintra.cz • Ing. Petr Novák – Business department manager: +420 604 237 033 novak@kpbintra.cz • Ing. Josef Stejskal – Technical department manager:+420 603 862 464 stejskal@kpbintra.cz www.kpbintra.com KPB INTRA s.r.o. , Ždánská 477, CZ-68501 Bučovice, tel.: +420 517 380 388, fax: +420 517 381 433, info@kpbintra.cz, www.kpbintra.com