380 likes | 603 Views
DENTAL EQUIPMENT DA 110 Pg’s 11-13 in lab book Not listed in order. Statim. Sterilizes Dental Instruments in 3.5-10 minutes Fill with Distilled Water. Waste Bottle for Statim. Waste container for used water from statim Water should not exceed the maximum level line
E N D
DENTAL EQUIPMENTDA 110Pg’s 11-13 in lab bookNot listed in order
Statim • Sterilizes Dental Instruments in 3.5-10 minutes • Fill with Distilled Water
Waste Bottle for Statim • Waste container for used water from statim • Water should not exceed the maximum level line • There should always be water inside the waste container above the minimum line
Nyclave Sealer • Seals the Nyclave tubing
X-Ray Processor: AT 2000 • Develops X-Rays • Found in the dark room
Ultrasonic Cleaner • Vibrates debris off of instruments • Undergoes a cavitation process where bubbles form
Plaster Trap • Filters the dental stone & plaster while trimming models • One under each sink where a model trimmer empties water and debris
Den Optics Scanner • Scans digital x-ray films into the computer
Sharps Container • Used to dispose of needles, glass, wire, and anything else that is sharp enough to puncture a balloon. • Sharps containers are leak proof, puncture resistant, and come in many sizes
Vacuum Former • Used to create custom trays, bleaching trays, and night guards
Model Trimmer • Trims dental models
Dental Lathe • Polishes dental models and dental prosthetics
PeriPro • Develops x-rays • Also know as a daylight loader
Sterilization Pouches • Used to hold instruments while they are in the autoclave • Note: Instruments are not taken out of the sterilization pouches until they are ready to be used
Light Cure Unit • Used to set (harden) dental materials • Polymerization occurs • Used with the orange paddle to shield the bright UV light
Steam Autoclave • Sterilizes dental instruments • Steam autoclave • Runs for ~ 30 minutes
Amalgamator • Mixes Dental Materials • Triturates dental materials
Lead Apron & Rod for Lead Apron • Lead apron shields the patient from x-rays • Rod for lead apron ensures that the lead apron will hang straight
Rheostat • Foot pedal that controls the speed of dental hand pieces
X-Ray Control Panel • Used to control the settings needed when taking x-ray images
X-Ray View Box • Used to view x-rays
Dental Stone Bin • Stone and plaster are kept here • Stone is used to make dental models like these:
Biohazard Container • Used to dispose of: • Anything saturated with blood • Pathological Waste • Teeth • Other body parts
Nyclave Tubing • Used to hold instruments during sterilization • Alternative to sterilization pouch • Used in conjunction with the Nyclave sealer • Process indicator tape is placed on the package
Debris Trap • Used to catch larger debris from the suctioning hoses • One in each operatory • Shows location in operatory
Air-Water Syringe(Also called 3-Way Syringe) • Used to spray air, water, or a combination of both • Used with an air water syringe tip (as pictured)
Saliva Ejector Hose • Used to suction water, saliva, and small debris from the oral cavity • Used with a saliva ejector tip (as shown in both pictures)
High Volume Evacuator (HVE) Hose • Used to suction large debris and water from the oral cavity • Used with an HVE tip attached to the hose (A) A
Water Bottle for Operatory • Provides water to the high speed handpiece and air water syringe • Must be filled with distilled water each day
Drawers • Drawers are used for storage
Passover between Operatories • Used to store masks, 2X2’s, 4X4’s, bibs, barriers, cotton swabs, etc.
Cold Sterile • Used to sterilize heat sensitive items • Instruments are stored in Glutaraldehyde solution for 10 hours to overnight
High Speed Connector Hose • Connects to high speed handpiece • High speed handpiece uses a friction grip bur and sprays air/water when being used • High speeds usually shine a light on the tooth when being used
Low speed Connector Hose • Hose that connects to the slow speed motor & handpiece • Slow speed handpiece uses a latch type bur • Slow speed handpiece does not spray air or water
Eye Wash Station • Used for flushing eyes in case of: • Contact with microorganisms is suspected • Contact with hazardous materials is suspected