1 / 21

WinTR-20 Project Formulation Hydrology Program to Convert HEC-RAS Output to WinTR-20 Cross Section

Learn how to import and modify HEC-RAS output into WinTR-20 for cross-section analysis and rating table creation. Step-by-step instructions provided.

morrissey
Download Presentation

WinTR-20 Project Formulation Hydrology Program to Convert HEC-RAS Output to WinTR-20 Cross Section

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. WinTR-20 Project Formulation Hydrology Program to Convert HEC-RAS Output to WinTR-20 Cross Section Presented by: WinTR-20 Development Team Import HEC-RAS Cross Section Tables March 2009

  2. Program to convert HEC-RAS output into WinTR-20 Cross Section • Program is incorporated into Windows interface; • Reads HEC-RAS text file created by the user thru HEC-RAS program; • After creating HEC-RAS output text file, open WinTR-20 Windows interface and click “File” then “Import HEC-RAS”; • Rating table program comes as a part of the Window WinTR-20 system. Import HEC-RAS Cross Section Tables March 2009

  3. Modify Profile Output Table • Bring up a project from HEC-RAS • Select “Profile Summary Table” from “View” menu . Import HEC-RAS Cross Section Tables March 2009

  4. Modify Profile Output Table • Profile Output Table-Standard Table 1 will appear. • Select “Define Table…” from “Options” pull down menu. Import HEC-RAS Cross Section Tables March 2009

  5. Modify Profile Output Table • Create a Table Heading window will appear. • Click on “Clear All Table Headings” • Double click to select – Min. Ch El, LOB Elev, ROB Elev,W.S.Elev, Q Total, Flow Area, Top Width, and E.G. Slope. Import HEC-RAS Cross Section Tables March 2009

  6. Modify Profile Output Table • After all eight columns have been selected. • Click on “Additional Options” tab. • Since only “Valley Cross Sections” are desired – the only box that should be checked is “Cross Sections” • Click “OK” to exit. Import HEC-RAS Cross Section Tables March 2009

  7. Modify Profile Output Table • Note the order of columns – Min Ch El, LOB Elev, ROB Elev, W.S.Elev, Q Total, Flow Area, Top Width, and E.G. Slope. • Save Profile Output Table by select “Save Table…” from the “Options” pull down menu. Import HEC-RAS Cross Section Tables March 2009

  8. Modify Profile Output Table • Enter name of new Table (Modify). Click “OK”. • The Profile Output Table-Modify is available under “User Tables” menu. Import HEC-RAS Cross Section Tables March 2009

  9. Modify Profile Output Table • Select all profiles (minimum 2) and all reaches. Profile Output Table-Modify must be saved as text file (Modify.txt). • Select “Write to Text File…” from “File” menu. Import HEC-RAS Cross Section Tables March 2009

  10. Modify Profile Output Table • Select an appropriate name for the text file (Modify.txt) • Select a directory • Click “Save” Import HEC-RAS Cross Section Tables March 2009

  11. Import HEC-RAS into WinTR-20 • Using Windows Explorer, go to the “WinTR20 Executables” directory and click on • The WinTR20 System Controller/ Editor window comes up: Import HEC-RAS Cross Section Tables March 2009

  12. Import HEC-RAS into WinTR-20 • Select “Import HEC-RAS” from “File” pulldown menu. • Locate the directory, select text file name (Modify.txt) Import HEC-RAS Cross Section Tables March 2009

  13. Import HEC-RAS into WinTR-20 • WinTR-20 Identifier window will pop up • Edit / Enter - Min. Hydrograph Value - Watershed Description • Click “Accept Changes (Close)” to close this window Import HEC-RAS Cross Section Tables March 2009

  14. Import HEC-RAS into WinTR-20 • Brings you back to the WinTR-20 System Controller / Editor window. • Click on “Stream Cross Section:” Note: (X indicates some data entered for section) Import HEC-RAS Cross Section Tables March 2009

  15. Import HEC-RAS into WinTR-20 • “Stream Cross Section” window will appear. • Select “Cross Section” from pull down menu. Import HEC-RAS Cross Section Tables March 2009

  16. Import HEC-RAS into WinTR-20 • Click “Display Data” button for graphical view of the Stream Cross Section Display Data. • Click “No Changes (Close)” button to close this window. Import HEC-RAS Cross Section Tables March 2009

  17. Import HEC-RAS into WinTR-20 • From “File” menu, select “SaveAs” – give a file name and location. • “Run” button is now available. Import HEC-RAS Cross Section Tables March 2009

  18. Import HEC-RAS into WinTR-20 • Try to “Run” WinTR-20 • Generated WinTR-20 Error File - No Stream Reach data - No Sub-Area data. - No Storm Analysis data. Import HEC-RAS Cross Section Tables March 2009

  19. Import HEC-RAS into WinTR-20 • Warning – do not import HEC-RAS data to an existing WinTR-20 file using the WinTR-20 Controller/Editor. The existing data will be erased and replaced by HEC-RAS tables. • Instead, save the WinTR-20 input file containing HEC-RAS rating tables, close WinTR-20, and use Notepad to copy and paste the data into the existing WinTR-20 data file. Import HEC-RAS Cross Section Tables March 2009

  20. The End Import HEC-RAS Cross Section Tables March 2009

  21. Import HEC-RAS Cross Section Tables March 2009

More Related