Diagnostic Accuracy of Rubidium-82 Myocardial Perfusion Imaging using PET CT. Normal Rubidium-82 Myocardial Perfusion PET-CT Study. Abnormal Rubidium-82 Myocardial Perfusion PET-CT Study. Limitations. Limitations.

morwen
Download Presentation

Diagnostic Accuracy of Rubidium-82 Myocardial Perfusion Imaging using PET CT

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Diagnostic Accuracy of Rubidium-82 Myocardial Perfusion Imaging using PET CT

  2. Normal Rubidium-82 Myocardial Perfusion PET-CT Study

  3. Abnormal Rubidium-82 Myocardial Perfusion PET-CT Study

  4. Limitations

  5. Limitations • May underestimate the anatomical extent of CAD in some patients with multivesseldisease. • Subclinical vessel disease may have normal perfusion studies. • Not all patients with normal perfusion study get CTA or Cath. Adds bias to the true Negative group

  6. Advantage of ECG-gated PET • Assess LV function at rest and during peak stress • Healthy pts: LVEF increases during peak vasodilator stress • Patients with left main or 3 vessel CAD show decrease in LVEF at peak stress even in the absence of perfusion abnormalities

  7. Sensitivity • 93% in single vessel disease. • 92% in multivessel disease. • May have a slight bias as many normals don’t have correlative coronary angiography. • MDCT angiography shows high degree of correlation with Rubidium-82 Myocardial Perfusion PET-CT.

  8. Integrated PET/CTA study

  9. Integrated PET/CTA study: • Noncalcified plaque (arrow) in proximal LAD with 50%–70% stenosis. However, rest and peak stress myocardial perfusion PET study (bottom left panel) demonstrates only minimal inferoapical ischemia.

  10. Conclusion • Myocardial perfusion PET-CT: • high sensitivity for detection of CAD. • applicable to both men and women, nonobese and obese patients. • Patients with single-vessel as well as multivessel coronary disease. • Rest and stress imaging is completed in approximately 25 min.