1 / 21

(240,)242 Pu( n,f ) measurement update

(240,)242 Pu( n,f ) measurement update. n_TOF Annual Collaboration Meeting Manchester, May 7-9, 2013. Outline. Detectors Time-evolution of detector response Analysis Latest data Resonance region, fission threshold High-energy region Simulations Summary.

moses
Download Presentation

(240,)242 Pu( n,f ) measurement update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. (240,)242Pu(n,f) measurement update n_TOF Annual Collaboration Meeting Manchester, May 7-9, 2013

  2. Outline • Detectors • Time-evolution of detector response • Analysis • Latest data • Resonance region, fission threshold • High-energy region • Simulations • Summary 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  3. Detector deterioration: the case of 240Pu • Very high α-activity of the samples (~6.4MBq/sample) • An unexpected alteration of some detectors was observed after removal from the chamber • A distinct discoloration of the micromesh is visible in the 4 detectors used with the 240Pu samples • Physical damage to the micromesh is visible under inspection with a microscope • This leads to a deterioration of the electrical field and a severe reduction of the gain • A unique – if inadvertent – ageing test 3cm 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  4. Detector deterioration: the case of 242Pu • The α-activity of the 242Pu samples is considerably lower (~0.13MBq/sample) • A similar visible discoloration was NOT observed • …but the detectors have not been studied under a microscope • A slow but significant deterioration of the gain is observed! • Now visible as data covers a few months of beam-time • Beam-off runs in det. #1 (242Pu) • Evolution during 2012 run 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  5. Detector deterioration: the case of 242Pu • Interestingly, one of the 4 detectors shows a sudden deterioration in mid-June • …goes from “normal” running to something that resembles the damaged 240Pu detectors • This happens over 2 days… • June 13-15, 2012 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  6. Detector deterioration: the case of 242Pu Start of 2012 run 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  7. Detector deterioration: the case of 242Pu End of 2012 run 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  8. Detector deterioration: the case of 242Pu • The quality of alpha / fission fragment separation suffers accordingly Start of 2012 run 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  9. Detector deterioration: the case of 242Pu • The quality of alpha / fission fragment separation suffers accordingly End of 2012 run 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  10. How does this affects the analysis? • Data need to be analysed in smaller bunches • This complicates things a bit on the software side… • …and makes the uncertainty estimations somewhat more problematic… 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  11. 235U(n,f) & 242Pu(n,f) – recorded counts (1000 bins per energy decade – ~60% of total acquired data) Absorption dips Resonances Baseline oscillation Spontaneous fission background 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  12. 235U(n,f) cross section • Using the evaluated n_TOF neutron flux… 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  13. 242Pu spontaneous fission background • The spontaneous fission background dominates the low energy region and remains visible up to about 1 keV. • Still, several resonances can be observed above this background. • SF background fitted with appropriate function 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  14. High-energy analysis • One step added in the data-processing flow • Matching structure of ROOT files created conventionally • Using the same analysis routines to extract the cross sections Cross section PEAK SEARCH Raw data DST files ROOT files ANALYSIS * RunNumber * EventNumb * PSpulse * PulseInte * FIMGdetn * FIMGsatfl * FIMGindex * FIMGtof Raw data ROOT files COMPENSATION * Detn * Time * ampl * eve * PSPulse * prot 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  15. High-energy analysis • Micromegas response to γ-flash • Initial γ-flash signal (hundreds of ns) • Baseline oscillation after the γ-flash lasts several μs and affects the high-energy data (>MeV) • “Compensation method” • Oscillations recorded in adjacent detectors for the same proton bunch are almost identical • Baseline oscillation can be subtracted from adjacent detector • One step added in the data-processing flow • Raw data are cleaned, the same peak-search routine is used to process the clean data • Only dedicated pulses are used (t0 recognition difficult in parasitic pulses) 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  16. Resolved resonances – Threshold region (normalised to ENDF) • First resonance at ~2.7eV • Visible over spontaneous fission background • Resolved resonances • At ~780eV and ~1830eV, two resonances not attributable to any of the stated sample impurities (at a preliminary analysis) • Fission threshold and above • Max. energy limit will be pushed as high as possible 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  17. Resolved resonances – Threshold region (normalised to ENDF) • First resonance at ~2.7eV • Visible over spontaneous fission background • Resolved resonances • At ~780eV and ~1830eV, two resonances not attributable to any of the stated sample impurities (at a preliminary analysis) • Fission threshold and above • Max. energy limit will be pushed as high as possible 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  18. Simulations • Reproducing signals from α-particles and fission fragments • Simplified geometry of samples and active detector volume created in FLUKA • Energy deposition is scored event-by-event and transformed to charge • Electron drift velocity calculated for given gas mixture and drift voltage (GARFIELD) • We can thus calculate the current reaching the readout electrode and “pass” it through an appropriate circuit to reconstruct the signal • A large time window is selected in which we randomly add: • white noise • α-particle and fission fragment pulses (at appropriate rates) Gas V Sample dE/dz 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  19. Simulations • Left: fission fragment pulse-height spectrum • Comparison of the real amplitude distribution of simulated fission fragments with the distribution extracted by the pulse analysis routine • Right: how does α-pile-up (especially in 240Pu) affect the α-particle amplitude spectrum? • A long tail at higher amplitudes appears (just like in experimental data) • Loss of fission fragments inside sample: <5% for 235U, <1% for 240,242Pu • Depending on the amplitude cut, the correction (i.e. fraction fission fragments included in the cut) varies between 80-95% 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  20. Summary • Outstanding issues • Efficiency / amplitude cut correction • Final breakdown of run groups for analysis • Data merging, uncertainty calculation • High-energy region • Unidentified resonances • Proceed with 2011 data • How should results obtained over time be combined to obtain the correct uncertainties? 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

  21. The end 240,242Pu(n,f) measurement | AT n_TOF Analysis Group Meeting - Manchester, May 7-9, 2013

More Related