An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chapter 3 Site Surveys and Preplanning Preliminary Assessment • Safety • Site Surveys • Preparing Proposals • Installation Planning

  2. The installer should meet with each customer to discuss available PV system options.

  3. Common personal protective equipment (PPE) for preparing and installing PV systems includes head, eye, foot, and fall protection.

  4. Lockout and tagout procedures are important parts of an electrical safety program.

  5. A personal fall arrest system protects a worker from injuries from falling from sloped roofs or roofs with unprotected edges.

  6. Fixed ladders often require cages and the use of PFASs to prevent workers from falling because the vertical orientation can be difficult to climb.

  7. Information gathered during a site survey should be carefully documented.

  8. A solar shading calculator is used to evaluate shading at potential array locations.

  9. A variety of testing and measuring devices and marking equipment is used during site surveys.

  10. The density of the module arrangement in an array affects the accessibility and the area required to produce a certain amount of power.

  11. Roof slope is measured with an angle finder or calculated from the rise and run.

  12. A compass is used to determine the orientation of a sloped roof surface.

  13. The potential loss in receivable solar radiation from non-optimal orientations may not be significant.

  14. Magnetic declination varies by location and changes slightly over time. Up-to-date maps are used to determine the necessary adjustment to magnetic compass readings.

  15. Directional bearings from magnetic compasses must be adjusted for magnetic declination.

  16. Shading of PV modules and arrays can cause disproportional reductions in power output.

  17. Most of the daily solar energy is received between 9 AM and 3 PM, so avoiding shading during this period is high priority, especially during the summer.

  18. When the sun is in the northern part of the sky, which can occur at low latitudes during the summer, shading can be caused by obstructions immediately north of an array.

  19. The Solar Pathfinder analyzes shading for potential array locations by comparing the reflections of potential obstructions on the horizon to a solar shading diagram of the solar window.

  20. A permanent record of the shading for a particular location can be traced on the hard copy diagram or by photographing the diagram, which can then be analyzed by the Solar Pathfinder Assistant software to generate reports.

  21. The Solmetric SunEye is an electronic shading analysis tool that includes an on-board camera with a fish-eye lens for photographing the entire sky and shading obstructions at once.

  22. The SunEye’s on-board software can automatically analyze an all-sky photograph the obstructions that will shade a location at certain times of the day and year.

  23. The altitude angle is the vertical angle to the top of an obstruction.

  24. Altitude angles can be determined using a transit, a protractor, or by calculations from measurements.

  25. The altitude angle method of shading analysis compares the altitude angle and azimuth angle of potential obstructions to a solar shading diagram.

  26. The profile angle is the projection of the solar altitude angle onto an imaginary plane perpendicular to a shading surface or obstruction. This angle is used to calculate the length of shadows.

  27. Profile angle calculations are particularly useful for arranging arrays consisting of multiple rows of modules installed at a tilt. The calculation determines the minimum row spacing to avoid modules shading each other at certain times of the day.

  28. Inner row shading can be summarized in a separation distance chart.

  29. Roofs should be inspected for signs of deterioration during a site survey.

  30. The thickness of roof decking and covering can be determined by inspecting the edge of the roof under the eaves.

  31. Noticeable dips on roof surfaces may be a sign of underlying structural defects.

  32. Inverters and other system components should be located as close together as possible.

  33. A site layout drawing shows basic building dimensions and locations of major components.

  34. A load analysis is part of an energy audit, which is used to evaluate a customer’s energy use for sizing PV systems utilizing batteries.

  35. Energy-use labels on new appliances include information on energy consumption and operating costs.