430 likes | 777 Views
Victron Energy B.V. Product presentation. Chargers :. 12 VDC from 7A to 200A. 24 VDC from 3A to 100A. 48 VDC from 25 to 50 A 12/24 VDC in multi voltage 90-265 VAC 12/24/48 VDC frequency 45 to 65 Hz 24 VDC 3 phase in 50 and 100A. Chargers IP20. Bluepower charger IP20
E N D
Victron Energy B.V. Productpresentation
Chargers : • 12 VDC from 7A to 200A. • 24 VDC from 3A to 100A. • 48 VDC from 25 to 50 A • 12/24 VDC in multivoltage 90-265 VAC • 12/24/48 VDC frequency 45 to 65 Hz • 24 VDC 3 phase in 50 and 100A.
Chargers IP20 • Bluepower charger IP20 • 12 VDC 7 to 15A • 24 VDC 5 to 8A • 90 to 265 VAC input • 90 to 350 VDC input • 45 to 65 Hz input • 4 stage adaptive • Fan for cooling
Chargers IP67 • Bluepower charger IP67 • 12 VDC 7 to 17A • 24 VDC 3 to 12A • 200 to 265 VAC input • 45 to 65 Hz input • 3 stage charging • IP 67 waterproff
Centauer charger • 12 VDC 20 to 200A • 24 VDC 16 to 100A • 90 to 265 VAC input • 90 to 400 VDC input • 45 to 65 Hz input • 3 stage charging • 3 full output • Internal temp. Sensor • Fan cooled • Dipswitch for select.
Phoenix chargers • 12 VDC 30 to 50A • 24 VDC 16 to 25A • 90 to 265 VAC input • 90 to 400 VDC input • 45 to 65 Hz input • 4 stage adaptive charge • Microprossersor • 2 full output + 4A • Externaltemp sensor • Set by laptop
Skylla chargers • 24 VDC 30 to 100A • 48 VDC 25 to 50A • Normal/univer/GMDSS • One or 3 phase • GMDSS in 30 and 50A • Use as power suply • Voltage/temp. Sense. • 3 step charger • Microprosessor • Germanischer Lloyd
Inverters • 12 VDC from 180VA to 5000VA • 24 VDC from 180VA to 5000VA • 48 VDC from 350VA to 5000VA • 120 VAC or 230 VAC output • All are pure sine waveinverters • Extra start up power. • 120 or 230 VAC output • 3 phase system 230/400 VAC • Up to 6 units in parallel
Inverter small case • 12/24 V 180 to 750 VA • 48 V 350 to 750 VA • Pure sine wave • Remotecontrol • Shuckoor IEC output • Extra start up power • Fan cooled
Inverterscompact • 12/24V 1200 to 2000VA • Pure sine wave • Remotewith UTP • Programming by laptop • Fan cooled • High start up power • Outsideconnections.
Invertersbig case • 12/24/48 VDC • 3000 to 5000 VA • Pure sine wave • VE-BUS system • Programming by laptop • Remote by UTP • High start up power • 6 pcs in parallel • 3 phase systems • Fan cooled
Inverter/chargers • 12/24 VDC from 800 VA to 5000 VA • 48 VDC from 3000 to 5000VA • Chargers from 16A to 200A • Transfer switch from 16 to 50 A • 120 or 230 VAC • Parallel and 3 phase systems likeinverters • Power asistent • Programing from laptopwith VE-BUS • Power control
CompactMulti/Multiplus • 12/24 VDC • 800 to 2000 VA • 16 to 80 A charger • 16 to 30 A transfer-relay • Pure sine wave inverter • Power asisten (not 800) • Adaptive charger • Remote panel with UTP • UPS function 20 M/s • Relay for external con.
Multiplus • 12/24/48 VDC • 3000 VA • 35 to 120 A charger • 16 to 50 A transfer-relay • Pure sine wave • Remote panel • UPS function • Power asistent • Relay for external con. • Parallel and 3 phase.
Quattro • 12/24/48 VDC • 3000 or 5000 VA • 70 to 200 A charger • 2 input and 2 output • Transfer switch on input • Nobreake and breake • 2 time 30 A trans.switch • Parallel and 3 phase • Relay for external con. • Remote and pure sine.
Isolations transformers • Isolations transformers 2000W to 7000W • Autotransformer 120/240 VAC-32A • Galvanic isolator 16A ( zincsaver) • Transformer from 115VAC to 230VAC
Isolations transformers • From 2000 to 7000W • Step up and down • 7000W only 230VAC • Build in softstart • Preventgalvaniccorrosion • Alsouse in fiberboats
Autotransformer • Zincsaver • - - - - - - - - - - - - - • Step up and down • Split phasebalancing • Generator use • Inverter use • Build in groundrelay
DC / DC converters • Not isolated 5 to 60A • IP65 in 5A • 20 to 60A batterycharge • 60A 2 pcs in parallel • 12/24 in 7 and10A • Isolated 100 to 360W • Input 12 to 96 VDC • Output 12 or 24VDC
Transfer switches • For inverter use • Max 3600 Watt • Switch time less 20Ms • Powerman 20 to 64A • 230 VAC or 3x400VAC
Battery monitors • 12/24 VDC • BMV600 onebattery • BMV602 twobatterys • BMV602 datalog • All informations/alarms • Roundorsquare • Plug and playwith RJ12 • 500A shunt • 20 to 9999A battery • Potential freecontact
VE.NET • 12 to 48 VDC • 256 nodes(battery/tank) • Std. UTP (RJ45) • All informations/alarms • Potetialfreecontact • Generator control • GSM module • Max 100M cabel
Battery isolators • Cyrix 12/24 or 24/48 • 100 / 200 / 400A • 200/400 4 settings • Autodetectvoltage • Novoltageloss • Emergencyconnect • Electronic engines
Battery isolators • Argo 70 160A • 2 or 3 battery´s • Voltage drop (0,45V) • Argo FET 100 or 200A • 2 or 3 battery´s • Lowvoltage drop (0,02) • + for electronicengines • + auto close
Batteryprotection • 40 / 60 and 200A • 12/24 V auto detect • Programmable • Overvoltageprotect • Disconnect in time • Alarm output • Ignitionproff
Batteries 6/225AH AGM 12V AGM 7 to 200AH 12/180AH AGM telecom 12V GEL 55 to 200AH 2V GEL OPzVtubular 2V FloodedOPzVtubular GEL 800 to 3000AH Flooded 600 to 3000AH
Otherproducts • Simpel battery alarm • Remotecontrols • Shoreconnections • System panels • Cables (UTP) • Balmaralternators • Multi Power Container solutions ready for use.
New Products 2009 • Victron Global remote Management • E-Plex panels for Multi / Quattro • New range of chargers (Skylla) • New range of inverters 10KVA -48VDC
Victron Global Remote - Future System state: inverter Alarms: none. Warnings: Low Battery. Battery: 22.35V 122.11A In: 0.00V 0.00A 0.00Hz Out: 230.47V 10.42A 49.89Hz GSM network Extra I/ONormally closed circuits