MidNiteSolar’sDisconnecting Combiners and the new 2014 NEC Rapid system shut down. MidNite Solar 360-403-7207
Ryan, Technical Support Manager ryan@midnitesolar.com 360-403-7207 XT151 MidNite Solar 360-403-7207
MidNite offers the Main Stayin Non-Disconnecting Combiners MidNite Solar 360-403-7207
MNPV6 being installed(Our most popular combiner) MidNite Solar 360-403-7207
MNPV3 Installed(Our second most popular) MidNite Solar 360-403-7207
We offer all of our combiners pre-wired with MC4 connectors. MidNite Solar 360-403-7207
MNPV6-Disco *Based on the MNPV6*AC and DC rated*120/240 3 circuit AC*150 volt 6 circuit DC*300 volt 3 circuit DC*120/240 AC and 600VDC MidNite Solar 360-403-7207
The inner Workings of theMNPV6 Disco MidNite Solar 360-403-7207
MNPV4HV-BasicDisconnecting 4 string combiner MidNite Solar 360-403-7207
MNPV4HV-Deluxe *Comes with fuses and fuse holders installed *Comes with Strain Reliefs and hole plugs *SPD600 (lightning Protection) included *Birdhouse compatible *Rapid system shutdown compatible MidNite Solar 360-403-7207
MNPV4HV Wiring MidNite Solar 360-403-7207
MNPV6HV-Disco 4X MidNite Solar 360-403-7207 Comes with Fuses, Fuse holders, SPD600, Strain reliefs, hole plugs and pre-punched holes.
MNPV6HV Wiring MidNite Solar 360-403-7207
MNPV8HV-Disco 3R or 4X *3R or 4X versions *Convertible (all bus bars included) *8 strings to a single inverter (175 amps output) *4 and 4 to 2 separate inverters (100+100 amps output) *4 strings to a transformer less inverter (100 amps output) *SPD600 included (Second needed for 4+4) *Hole Plugs and strain reliefs included *Fuses and Fuse holders included MidNite Solar 360-403-7207
8 parallel strings(as shipped) MidNite Solar 360-403-7207
Convertible Combiners *High current copper bus bars supplied for all configurations*Some configurations allow for the removal of two 200 amp 600V insulated bus bars*Extra hole plugs are useful elsewhere*Extra strain reliefs are useful elsewhere*Recycle bus bars and buy yourself a pizza MidNite Solar 360-403-7207
MNPV16HV-Disco 4XSame features as the MNPV8HV MidNite Solar 360-403-7207
Nema 4X testing *Gasket was totally redesigned *Paint was changed to smooth *Silicone added to hinge and latch rivets *10,000 hole plugs scrapped and redesigned *Seal screws incorporated *Welded seams improved *The competition does not meet the criteria MidNite Solar 360-403-7207
Is a plastic, fiberglass or steel box going to be water tight 20 or 30 years down the road? Will the plastic boxes turn to dust in Phoenix? Will the steel boxes rust out in Seattle? Will the paint still be on the aluminum MidNite boxes 50 years from now? Nema 4X testing MidNite Solar 360-403-7207
Emergency disconnect (The Birdhouse)Hard wired to one or many Disconnecting combiners using our custom 600V USE-2 90C CAT5 cable MidNite Solar 360-403-7207
2014 NEC Rapid Shutdown Proposed changes to NEC 690.12 Rapid Shutdown of PV Systems on BuildingsRequires PV array combiner and Inverter Battery terminals to be shut down below 30VDC in ten seconds MidNite Solar 360-403-7207
Rapid ShutdownRapid shutdown system forbattery based systems. Multiple Combiners and Inverters supported MidNite Solar 360-403-7207
Multiple breaker styles that are compatible with the Rapid Shutdown system Rapid shutdown MidNite Solar 360-403-7207
Questions? Ryan Stankevitz MidNite Solar 360-403-7207 XT 151 ryan@midnitesolar.com Andrea Belford Product Manager Alt E 1-877-878-4060 XT 168